A far-red-emissive AIE active fluorescent probe with large stokes shift for detection of inflammatory bowel disease in vivo

被引:21
|
作者
Xu, Wanfu [1 ,2 ]
He, Liying [1 ]
Xia, Qi [3 ]
Jia, Chunhong [4 ]
Geng, Lanlan [1 ]
Yang, Min [1 ]
Xu, Zhaohui [1 ]
Chen, Peiyu [1 ]
Cheng, Yang [1 ,2 ]
Zhao, Junhong [1 ]
Wang, Hongli [1 ]
Chen, Huan [1 ]
Zhang, Yuhua [5 ]
Gong, Sitang [1 ,2 ]
Liu, Ruiyuan [3 ]
机构
[1] Guangzhou Med Univ, Guangzhou Women & Childrens Med Ctr, Dept Gastroenterol, Guangzhou 510623, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Guangzhou Women & Childrens Med Ctr, Guangzhou Inst Paediat, Guangzhou 510623, Guangdong, Peoples R China
[3] Southern Med Univ, Sch Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[4] Guangzhou Med Univ, Affiliated Hosp 3, Dept Paediat, Guangzhou 510150, Guangdong, Peoples R China
[5] Ninety Five Hosp Chinese PLA, Dept Paediat, Putian 351100, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
TIGHT JUNCTION PROTEIN; AGGREGATION-INDUCED EMISSION; BARRIER FUNCTION; ORGANIC NANOPARTICLES; CELL TRACKING; CANCER; DIAGNOSIS; IEC-6; RISK; DOTS;
D O I
10.1039/c7tb03168h
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Inflammatory bowel disease (IBD) is a group of chronic remittent or progressive inflammatory gastrointestinal tract diseases, accompanying impaired barrier function. Effective real-time monitoring of the IBD progression in time is critical to the success of bowel therapy and the improvement of patient outcomes. However, there is relatively little information regarding the detection of the intestinal barrier. In this study, we have judiciously designed and synthesized a novel D-pi-A based far-red-emissive AIE active fluorescent Probe (PTZB-FR). PTZB-FR exhibits properties suitable for in vivo imaging, such as FR emission, good photostability, large Stokes shift (similar to 184 nm), and low cytotoxicity. Moreover, confocal fluorescence microscopy and flow cytometry assay reveal the effective internalization of PTZB-FR. Most importantly, imaging living mice after oral administration of PTZB-FR confirms that fluorescence in the intestinal lumen diminishes in Dextran sulfate sodium (DSS)-induced colitis, which is attributed to disruption of intestinal barrier integrity caused by a DSS-induced colitis model, highlighting PTZB-FR as a promising reagent in the detection of intestinal barrier function during clinical examination.
引用
收藏
页码:809 / 815
页数:7
相关论文
共 50 条
  • [21] A phthalimide-based fluorescent probe for thiol detection with a large Stokes shift
    Liu, Xingjiang
    Gao, Li
    Yang, Liu
    Zou, Lifen
    Chen, Wenqiang
    Song, Xiangzhi
    RSC ADVANCES, 2015, 5 (24): : 18177 - 18182
  • [22] Development of a fast-responsive and turn on fluorescent probe with large Stokes shift for specific detection of cysteine in vivo
    Yang, Cui-Feng
    Zeng, Li-Yuan
    Ning, Bin-Ke
    Wang, Jian-Yong
    Zhang, Haitao
    Zhang, Zhi-Hao
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 225 (225)
  • [23] A colorimetric and ratiometric fluorescent probe with a large stokes shift for detection of hydrogen sulfide
    Xiang, Kaiqiang
    Liu, Yunchang
    Li, Changjiang
    Tian, Baozhu
    Tong, Tianzhong
    Zhang, Jinlong
    DYES AND PIGMENTS, 2015, 123 : 78 - 84
  • [24] A red-emitting fluorescent probe for imaging hydrogen sulphide with a large Stokes shift
    Chen, Song
    Hou, Peng
    Song, Xiangzhi
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 951 - 955
  • [25] Specific tracking of monoamine oxidase A in heart failure models by a far-red fluorescent probe with an ultra large Stokes shift
    Li, Xinming
    Shi, Donglei
    Song, Yihe
    Xu, Yixiang
    Gao, Ying
    Qiu, Wenjing
    Chen, Xin
    Li, Xiaokang
    Huang, Yunyuan
    Feng, Yanjun
    Li, Baoli
    Guo, Yuan
    Li, Jian
    CHINESE CHEMICAL LETTERS, 2022, 33 (03) : 1572 - 1576
  • [26] Specific tracking of monoamine oxidase A in heart failure models by a far-red fluorescent probe with an ultra large Stokes shift
    Xinming Li
    Donglei Shi
    Yihe Song
    Yixiang Xu
    Ying Gao
    Wenjing Qiu
    Xin Chen
    Xiaokang Li
    Yunyuan Huang
    Yanjun Feng
    Baoli Li
    Yuan Guo
    Jian Li
    Chinese Chemical Letters, 2022, 33 (03) : 1572 - 1576
  • [27] Red fluorescent AIE bioprobes with a large Stokes shift for droplet-specific imaging and fatty liver diagnosis
    Cai, Yu-Ting
    Liu, Yan-Chao
    Gu, Ying-Ying
    Zhu, Ya-Qi
    Liu, Yong-Hong
    Chen, Jing
    Yang, Yuan
    Liu, Ming-Xuan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 327
  • [28] A D-π-A-based near-infrared fluorescent probe with large Stokes shift for the detection of cysteine in vivo
    Fang, Wen-Le
    Liang, Zhi-Yong
    Guo, Xiao-Feng
    Wang, Hong
    TALANTA, 2024, 268
  • [29] Monitoring of Peroxynitrite Variation During Liver Injury Adopting a Far Red to Near-infrared Fluorescent Probe with Large Stokes Shift
    Wu, Qian
    Cheng, Dan
    Lu, Yun
    Yuan, Lin
    Zhang, Xiaobing
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2020, 41 (11): : 2426 - 2434
  • [30] Near-infrared fluorescent probe with large Stokes shift for specific detection of lysine
    Yu, Jirui
    Fan, Ji
    Song, Yanxi
    Zhao, Yong
    Lin, Ziyun
    Jiang, Lin
    Li, Hongqi
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 308