Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking

被引:169
|
作者
Xu, Xu [1 ]
McGorry, Raymond W. [1 ]
Chou, Li-Shan [2 ]
Lin, Jia-hua [3 ]
Chang, Chien-chi [4 ]
机构
[1] Liberty Mutual Res Inst Safety, Hopkinton, MA 01748 USA
[2] Univ Oregon, Dept Human Physiol, Eugene, OR 97403 USA
[3] Washington State Dept Labor & Ind, Safety & Hlth Assessment & Res Prevent SHARP Prog, Olympia, WA 98504 USA
[4] Natl Tsing Hua Univ, Dept Ind Engn & Engn Management, Hsinchu, Taiwan
关键词
Gait analysis; Knee and hip joint angle; Step time; Step width; VALIDITY; RELIABILITY; MOTION;
D O I
10.1016/j.gaitpost.2015.05.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The measurement of gait parameters normally requires motion tracking systems combined with force plates, which limits the measurement to laboratory settings. In some recent studies, the possibility of using the portable, low cost, and marker-less Microsoft Kinect (TM) sensor to measure gait parameters on over-ground walking has been examined. The current study further examined the accuracy level of the Kinect sensor for assessment of various gait parameters during treadmill walking under different walking speeds. Twenty healthy participants walked on the treadmill and their full body kinematics data were measured by a Kinect sensor and a motion tracking system, concurrently. Spatiotemporal gait parameters and knee and hip joint angles were extracted from the two devices and were compared. The results showed that the accuracy levels when using the Kinect sensor varied across the gait parameters. Average heel strike frame errors were 0.18 and 0.30 frames for the right and left foot, respectively, while average toe off frame errors were -2.25 and -2.61 frames, respectively, across all participants and all walking speeds. The temporal gait parameters based purely on heel strike have less error than the temporal gait parameters based on toe off. The Kinect sensor can follow the trend of the joint trajectories for the knee and hip joints, though there was substantial error in magnitudes. The walking speed was also found to significantly affect the identified timing of toe off. The results of the study suggest that the Kinect sensor may be used as an alternative device to measure some gait parameters for treadmill walking, depending on the desired accuracy level. (C) 2015 The Authors. Published by Elsevier B.V.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [31] RELIABILITY OF TEMPORAL AND SPATIAL GAIT PARAMETERS DURING TREADMILL WALKING IN COMMUNITY-DWELLING HEALTHY SENIORS
    Donath, Lars
    Zahner, Lukas
    Roth, Ralf
    Fricker, Livia
    Faude, Oliver
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2012, 20 : S177 - S177
  • [32] Asymmetry of short-term control of spatio-temporal gait parameters during treadmill walking
    Klaudia Kozlowska
    Miroslaw Latka
    Bruce J. West
    Scientific Reports, 7
  • [33] Asymmetry of short-term control of spatio-temporal gait parameters during treadmill walking
    Kozlowska, Klaudia
    Latka, Miroslaw
    West, Bruce J.
    SCIENTIFIC REPORTS, 2017, 7
  • [34] Gait parameters and stride-to-stride variability during familiarization to walking on a split-belt treadmill
    Zeni, Joseph A., Jr.
    Higginson, Jill S.
    CLINICAL BIOMECHANICS, 2010, 25 (04) : 383 - 386
  • [35] Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining
    Clark, Ross A.
    Pua, Yong-Hao
    Bryant, Adam L.
    Hunt, Michael A.
    GAIT & POSTURE, 2013, 38 (04) : 1064 - 1066
  • [36] Ground Reaction Forces and Gait Parameters during Motorized and Non-Motorized Treadmill Walking and Running on the International Space Station Treadmill
    Norcross, Jason
    DeWitt, John
    Lee, Stuart M. C.
    McCleary, Frank
    Edwards, W. Brent
    Hagan, R. Donald
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S122 - S122
  • [37] A comparison of variability in spatiotemporal gait parameters between treadmill and overground walking conditions
    Hollman, John H.
    Watkins, Molly K.
    Imhoff, Angela C.
    Braun, Carly E.
    Akervik, Kristen A.
    Ness, Debra K.
    GAIT & POSTURE, 2016, 43 : 204 - 209
  • [38] Cognitive performance during gait is worsened by overground but enhanced by treadmill walking
    Penati, Rachele
    Schieppati, Marco
    Nardone, Antonio
    GAIT & POSTURE, 2020, 76 : 182 - 187
  • [39] Selection of gait parameters during constrained walking
    Qiao, Mu
    Sha, Zhanxin
    HUMAN MOVEMENT SCIENCE, 2023, 89
  • [40] Entrainment of chewing rhythm by gait speed during treadmill walking in humans
    Maezawa, Hitoshi
    Koganemaru, Satoko
    Matsuhashi, Masao
    Hirata, Masayuki
    Funahashi, Makoto
    Mima, Tatsuya
    NEUROSCIENCE RESEARCH, 2020, 156 : 88 - 94