Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking

被引:169
|
作者
Xu, Xu [1 ]
McGorry, Raymond W. [1 ]
Chou, Li-Shan [2 ]
Lin, Jia-hua [3 ]
Chang, Chien-chi [4 ]
机构
[1] Liberty Mutual Res Inst Safety, Hopkinton, MA 01748 USA
[2] Univ Oregon, Dept Human Physiol, Eugene, OR 97403 USA
[3] Washington State Dept Labor & Ind, Safety & Hlth Assessment & Res Prevent SHARP Prog, Olympia, WA 98504 USA
[4] Natl Tsing Hua Univ, Dept Ind Engn & Engn Management, Hsinchu, Taiwan
关键词
Gait analysis; Knee and hip joint angle; Step time; Step width; VALIDITY; RELIABILITY; MOTION;
D O I
10.1016/j.gaitpost.2015.05.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The measurement of gait parameters normally requires motion tracking systems combined with force plates, which limits the measurement to laboratory settings. In some recent studies, the possibility of using the portable, low cost, and marker-less Microsoft Kinect (TM) sensor to measure gait parameters on over-ground walking has been examined. The current study further examined the accuracy level of the Kinect sensor for assessment of various gait parameters during treadmill walking under different walking speeds. Twenty healthy participants walked on the treadmill and their full body kinematics data were measured by a Kinect sensor and a motion tracking system, concurrently. Spatiotemporal gait parameters and knee and hip joint angles were extracted from the two devices and were compared. The results showed that the accuracy levels when using the Kinect sensor varied across the gait parameters. Average heel strike frame errors were 0.18 and 0.30 frames for the right and left foot, respectively, while average toe off frame errors were -2.25 and -2.61 frames, respectively, across all participants and all walking speeds. The temporal gait parameters based purely on heel strike have less error than the temporal gait parameters based on toe off. The Kinect sensor can follow the trend of the joint trajectories for the knee and hip joints, though there was substantial error in magnitudes. The walking speed was also found to significantly affect the identified timing of toe off. The results of the study suggest that the Kinect sensor may be used as an alternative device to measure some gait parameters for treadmill walking, depending on the desired accuracy level. (C) 2015 The Authors. Published by Elsevier B.V.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [1] Validity of Microsoft Kinect™ for measuring gait parameters
    Kharazi, M. R.
    Memari, A. H.
    Shahrokhi, A.
    Nabavi, H.
    Khorami, S.
    Rasooli, A. H.
    Barnamei, H. R.
    Jamshidian, A. R.
    Mirbagheri, M. M.
    2015 22ND IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2015, : 375 - 379
  • [2] Quantitative evaluation of parameters affecting the accuracy of Microsoft Kinect in GAIT analysis
    Jamali, Zahra
    Behzadipour, Saeed
    2016 23RD IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING AND 2016 1ST INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2016, : 301 - 306
  • [3] Detection of gait cycles in treadmill walking using a Kinect
    Auvinet, Edouard
    Multon, Franck
    Aubin, Carl-Eric
    Meunier, Jean
    Raison, Maxime
    GAIT & POSTURE, 2015, 41 (02) : 722 - 725
  • [4] Validity of the microsoft kinect system in assessment of compensatory stepping behavior during standing and treadmill walking
    Shani, Guy
    Shapiro, Amir
    Oded, Goldstein
    Dima, Kagan
    Melzer, Itshak
    EUROPEAN REVIEW OF AGING AND PHYSICAL ACTIVITY, 2017, 14
  • [5] Validity of the microsoft kinect system in assessment of compensatory stepping behavior during standing and treadmill walking
    Guy Shani
    Amir Shapiro
    Goldstein Oded
    Kagan Dima
    Itshak Melzer
    European Review of Aging and Physical Activity, 2017, 14
  • [6] Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters
    Dolatabadi, Elham
    Taati, Babak
    Mihailidis, Alex
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (09) : 952 - 958
  • [7] THE EFFECT OF BODY WEIGHT UNLOADING ON KINEMATIC GAIT PARAMETERS DURING TREADMILL WALKING
    Duda, S.
    Gembalczyk, G.
    Jureczko, P.
    ENGINEERING MECHANICS 2017, 2017, : 282 - 285
  • [8] Spatiotemporal Parameters of Gait During Treadmill and Overground Walking in Parkinson's Disease
    Bello, Olalla
    Sanchez, Jose Andres
    Vazquez-Santos, Cristina
    Fernandez-Del-Olmo, Miguel
    JOURNAL OF PARKINSONS DISEASE, 2014, 4 (01) : 33 - 36
  • [9] Gait symmetry quantification during treadmill walking
    Karaharju-Huisman, T
    Taylor, S
    Begg, R
    Cai, J
    Best, R
    ANZIIS 2001: PROCEEDINGS OF THE SEVENTH AUSTRALIAN AND NEW ZEALAND INTELLIGENT INFORMATION SYSTEMS CONFERENCE, 2001, : 203 - 206
  • [10] Hemiparetic gait parameters in overground versus treadmill walking
    Harris-Love, ML
    Forrester, LW
    Macko, RF
    Silver, KHC
    Smith, GV
    NEUROREHABILITATION AND NEURAL REPAIR, 2001, 15 (02) : 105 - 112