CALIBRATION OF THE HIGH AND LOW RESOLUTION GAMMA-RAY SPECTROMETERS

被引:0
|
作者
Luca, Aurelian [1 ]
Neacsu, Beatris [1 ]
Antohe, Andrei [1 ]
Sahagia, Maria [1 ]
机构
[1] IFIN HH Bucharest, Horia Hulubei Natl Inst Phys & Nucl Engn, RO-077125 Bucharest, Romania
关键词
Gamma-ray spectrometry; calibration; activity measurements;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Many laboratories accredited according to the requirements of the standard EN ISO/IEC 17025:2005 "General requirements for the competence of testing and calibration laboratories" are implied in the radioactive content measurement of samples collected from the environment, food chain or industrial products. The most used method is the gamma-ray spectrometry measurement, using high resolution HPGe and low resolution NaI(Tl) detectors. In order to improve its sensitivity, many technical and methodological aspects are important: careful choice of detector material and shielding, samples matrix, measurement of high volume samples in close to detector geometries. The results are strongly influenced by the geometry, sample volume and content, and true coincidence summing effects (for cascade gamma-ray emitters), as demonstrated during many proficiency tests. The Radionuclide Metrology Laboratory from IFIN-HH, Primary Activity Standard Laboratory, assures the continuity of the whole metrological traceability chain of activity measurement and is accredited by the national accreditation body RENAR as a Calibration and Testing Laboratory, offering products and services for clients. Within the frame of its QMS, RML elaborated two working procedures for the calibration of the gamma-ray spectrometers and the low level radioactive samples activity measurement. The calibration procedures are described, emphasizing the corrections applicable by the measurement laboratories.
引用
收藏
页码:968 / 976
页数:9
相关论文
共 50 条
  • [21] Use of 166mHo for calibration of gamma-ray spectrometers with semiconductor detectors
    Konstantinov, A.A.
    Kurenkov, N.V.
    Malinin, A.B.
    Sazonova, T.E.
    Sepman, S.V.
    Soviet atomic energy, 1990, 67 (03): : 696 - 698
  • [22] PORTABLE GAMMA-RAY SPECTROMETERS.
    Anon
    International Atomic Energy Agency, Technical Report Series, 1974, (158): : 25 - 22
  • [23] THE NEW BNL HIGH-ENERGY GAMMA-RAY SPECTROMETERS
    SANDORFI, AM
    COLLINS, MT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (03): : 479 - 495
  • [24] FUTURE OF SEMICONDUCTOR GAMMA-RAY SPECTROMETERS
    ARMANTROUT, GA
    YEE, JH
    SHEROHMAN, JW
    SWIERKOWSKI, SP
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 22 (NOV16): : 123 - 123
  • [25] HARD X-RAY AND LOW-ENERGY GAMMA-RAY SPECTROMETERS
    GEHRELS, N
    CRANNELL, CJ
    FORREST, DJ
    LIN, RP
    ORWIG, LE
    STARR, R
    SOLAR PHYSICS, 1988, 118 (1-2) : 233 - 268
  • [26] Radiation stability of High Pressure Xenon gamma-ray spectrometers
    Dmitrenko, VV
    Dvornyak, AG
    Galper, AM
    Gratchev, VM
    Kondakova, ON
    Krivov, SV
    Krivova, KV
    Liagushin, VI
    Ulin, SE
    Uteshev, ZM
    Vlasik, KF
    Yurkin, YT
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 102 - 106
  • [27] A RELIABLE AND ACCURATE PROCEDURE FOR PREPARING LOW-ACTIVITY EFFICIENCY CALIBRATION STANDARDS FOR GERMANIUM GAMMA-RAY SPECTROMETERS
    CROUDACE, IW
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1991, 153 (02): : 151 - 162
  • [28] Energy Calibration Method for an All-digital High Resolution Gamma-ray Spectroscopy
    Long, Anwen
    Zhang, Qiude
    Xiong, Zhangjing
    Xiao, Peng
    Xie, Qingguo
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [30] Ultrahigh energy resolution gamma-ray spectrometers for precision measurements of uranium enrichment
    Ali, S.
    Hau, I. D.
    Niedermayr, T. R.
    Friedrich, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (03) : 749 - 753