Preliminary assessment of flow, notch toughness, and high temperature behavior of CU60Zr20Hf10Ti10 bulk metallic glass

被引:66
|
作者
Wesseling, P
Nieh, TG
Wang, WH
Lewandowski, JJ
机构
[1] Case Western Reserve Univ, Dept Mat Sci & Engn, Cleveland, OH 44106 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
[3] Chinese Acad Sci, Inst Phys, Beijing 100080, Peoples R China
[4] Univ Cambridge, Dept Mech & Mat Sci, Cambridge CB2 1TN, England
关键词
copper alloys; metallic glasses; mechanical properties; toughness;
D O I
10.1016/j.scriptamat.2004.03.034
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Microhardness, hot hardness, uniaxial compression, and notched bending experiments were conducted on Cu60Zr20Hf10Ti10 bulk metallic glass (BMG). This Cu-based BMG possesses near theoretical strength but essentially zero compressive ductility at room temperature. Notch toughness values in excess of 65 MParootm were obtained, while significant softening was obtained near T-q (C) 2004 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:151 / 154
页数:4
相关论文
共 50 条
  • [31] Superplastic formability of the developed Zr40Hf10Ti5Al10Cu25Ni10 high entropy bulk metallic glass with enhanced thermal stability
    Dehkordi, Zahra Kouhi
    Malekan, Mehdi
    Nili-Ahmadabadi, Mahmoud
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2022, 576
  • [32] Theological behavior of bulk metallic glass Zr41Ti14Cu12.5Ni10Be22.5
    Wang, Jing-Feng
    Liu, Lin
    Pu, Jian
    Xiao, Jian-Zhong
    Wuli Xuebao/Acta Physica Sinica, 2004, 53 (06): : 1916 - 1922
  • [33] In vitro biocompatibility assessment of Ti40Cu38Zr10Pd12 bulk metallic glass
    A. Blanquer
    E. Pellicer
    A. Hynowska
    L. Barrios
    E. Ibáñez
    M. D. Baró
    J. Sort
    C. Nogués
    Journal of Materials Science: Materials in Medicine, 2014, 25 : 163 - 172
  • [34] In vitro biocompatibility assessment of Ti40Cu38Zr10Pd12 bulk metallic glass
    Blanquer, A.
    Pellicer, E.
    Hynowska, A.
    Barrios, L.
    Ibanez, E.
    Baro, M. D.
    Sort, J.
    Nogues, C.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (01) : 163 - 172
  • [35] Is Cu60Ti10Zr30 a bulk glass-forming alloy?
    Jiang, JZ
    Saida, J
    Kato, H
    Ohsuna, T
    Inoue, A
    APPLIED PHYSICS LETTERS, 2003, 82 (23) : 4041 - 4043
  • [36] Characterization of nanocrystal dispersed Cu60Zr30Ti10 metallic glass
    Nagahama, D
    Ohkubo, T
    Mukai, T
    Hono, K
    MATERIALS TRANSACTIONS, 2005, 46 (06) : 1264 - 1270
  • [37] Pressure-dependent flow behavior of Zr41.2Ti13.8Cu12.5Ni10Be22.5 bulk metallic glass
    Lu, J
    Ravichandran, G
    JOURNAL OF MATERIALS RESEARCH, 2003, 18 (09) : 2039 - 2049
  • [38] Pressure-dependent flow behavior of Zr41.2Ti13.8Cu12.5Ni10Be22.5 bulk metallic glass
    Jun Lu
    Guruswami Ravichandran
    Journal of Materials Research, 2003, 18 : 2039 - 2049
  • [39] Oxidation-induced copper segregation in Cu60Zr30 Ti10 bulk metallic glass
    Tam C.Y.
    Shek C.H.
    Journal of Materials Research, 2006, 21 (4) : 851 - 855
  • [40] Enhancement of solderability of Cu60Zr30Ti 10 bulk metallic glass by dealloying in hydrofluoric acid solution
    Naoi T.
    Nishikawa H.
    Takemoto T.
    Abe H.
    Fukuhara M.
    Inoue A.
    Yosetsu Gakkai Ronbunshu/Quarterly Journal of the Japan Welding Society, 2011, 29 (03): : 147s - 150s