Measuring diagnostic accuracy for biomarkers under tree-ordering

被引:3
|
作者
Feng, Yingdong [1 ]
Tian, Lili [1 ]
机构
[1] SUNY Buffalo, Dept Biostat, 717 Kimball Tower,3435 Main St, Buffalo, NY 14214 USA
关键词
ROC curve; ROC curve for tree ordering; area under TROC; false negative rate; confidence region; generalized inference; GENERALIZED P-VALUES; ROC CURVE; POINT SELECTION; INFERENCES;
D O I
10.1177/0962280218755810
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
In the field of diagnostic studies for tree or umbrella ordering, under which the marker measurement for one class is lower or higher than those for the rest unordered classes, there exist a few diagnostic measures such as the naive AUC (NAUC), the umbrella volume (UV), and the recently proposed TAUC, i.e. area under a ROC curve for tree or umbrella ordering (TROC). However, an important characteristic about tree or umbrella ordering has been neglected. This paper mainly focuses on promoting the use of the integrated false negative rate under tree ordering (ITFNR) as an additional diagnostic measure besides TAUC, and proposing the idea of using (TAUC, ITFNR) instead of TAUC to evaluate the diagnostic accuracy of a biomarker under tree or umbrella ordering. Parametric and non-parametric approaches for constructing joint confidence region of (TAUC, ITFNR) are proposed. Simulation studies under a variety of settings are carried out to assess and compare the performance of these methods. In the end, a published microarray data set is analyzed.
引用
收藏
页码:1328 / 1346
页数:19
相关论文
共 50 条
  • [21] Measuring diagnostic accuracy of imaging parameters in pelvic lipomatosis
    Zhang, Yudong
    Wu, Shiliang
    Xi, Zhijun
    Wang, Xiaoying
    Jiang, Xuexiang
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3107 - 3114
  • [22] MEASURING DIAGNOSTIC-ACCURACY IN THE ABSENCE OF A GOLD STANDARD
    FARAONE, SV
    TSUANG, MT
    AMERICAN JOURNAL OF PSYCHIATRY, 1994, 151 (05): : 650 - 657
  • [23] Ordering of diagnostic information in encoded medical images.: Accuracy progression
    Przelaskowski, A.
    Jozwiak, R.
    Krzyzewski, T.
    Worlewska, A.
    OPTO-ELECTRONICS REVIEW, 2008, 16 (01) : 49 - 59
  • [24] Ordering of diagnostic information in encoded medical images. Accuracy progression
    Institute of Radioelectronics, Warsaw University of Technology, 15/19 Nowowiejska Str., Warsaw 00-665, Poland
    Opto-electron. Rev., 1 (49-59):
  • [25] Testing the accuracy of imaging software for measuring tree root volumes
    Koeser, Andrew K.
    Roberts, John W.
    Miesbauer, Jason W.
    Lopes, Angelica Bannwart
    Kling, Gary J.
    Lo, Marvin
    Morgenroth, Justin
    URBAN FORESTRY & URBAN GREENING, 2016, 18 : 95 - 99
  • [26] Role of circulating exosomal biomarkers and their diagnostic accuracy in pancreatic cancer
    Sha, Menazir
    Kunduzi, Basir
    Froghi, Saied
    Quaglia, Alberto
    Davidson, Brian
    Fusai, Giuseppe K.
    JGH OPEN, 2023, 7 (01): : 30 - 39
  • [27] Combining biomarkers to improve diagnostic accuracy using the overlap coefficient
    Coolen-Maturi, Tahani
    COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2025,
  • [28] A STUDY ON THE ASSESSMENT OF DIAGNOSTIC ACCURACY OF DIFFERENT BIOMARKERS FOR PROSTATE CANCER
    Tariq, Kifayat
    Ul Wahab, Mehboob
    Ishtiaq, Mohammad
    Ahmed, Kamran
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (03): : 5562 - 5566
  • [29] DIAGNOSTIC ACCURACY OF EARLY BIOMARKERS FOR ACUTE CORONARY SYNDROME (ACS)
    Carroll, C.
    Goodacre, S.
    Stevens, J.
    Al Khalaf, M.
    Leaviss, J.
    Wang, J.
    Collinson, P.
    VALUE IN HEALTH, 2012, 15 (07) : A361 - A361
  • [30] Diagnostic accuracy of biomarkers of oxidative stress in parapneumonic pleural effusions
    Tsilioni, Irene
    Kostikas, Konstantinos
    Kalomenidis, Ioannis
    Oikonomidi, Smaragda
    Tsolaki, Vassiliki
    Minas, Markos
    Gourgoulianis, Konstantinos I.
    Kiropoulos, Theodoros S.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2011, 41 (04) : 349 - 356