The Influence of Volume Surface Ratio of Rectangle Air-conditioning Duct on Particle Deposition

被引:1
|
作者
Zhang, Jie [1 ]
Liu, Zehua [1 ]
Liu, Yuanquan [1 ]
Li, Huimin [1 ]
Ning, Yongfei [1 ]
机构
[1] Univ S China, Sch Urban Construct, Changsha 421001, Hunan, Peoples R China
关键词
Particle; Deposition; Volume surface ratio of duct; Numerical simulation; VENTILATION DUCTS; TURBULENT-FLOW;
D O I
10.4028/www.scientific.net/AMM.71-78.3633
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper discusses particle deposition in rectangle air-conditioning duct using RSM (Reynold Stress Model) and random trajectory particle model. Particle with nominal diameters of 10-200 mu m are simulated at each of three nominal air speed: 4m/s, 6m/s and 8m/s, respectively, in the cross-section sizes of 160x120, 500x250, 1000x320mm In simulation, the paper compares and analyzes the influence factors of particles deposition in volume surface ratio of the given duct. The results show that: 1) particle deposition velocity increases with volume surface ratio; 2) As the inlet air speed increasing, when the particles deposited to floor and vertical wall, the image of dimensionless deposition velocity Vs dimensionless relaxation time shows a coincident trend when the duct cross-section sizes are 500x250, 1000x320mm, but has great differences with the image of 160x120mm.
引用
收藏
页码:3633 / 3638
页数:6
相关论文
共 50 条
  • [41] Variable-air-volume air-conditioning system under reduced static pressure control
    Dah Chong Hong Ltd, Kowloon, Hong Kong
    Build Serv Eng Res Technol, 2 (77-83):
  • [42] Influence of the surface area/volume ratio on the chemistry of carbon deposition from methane
    Hu, ZJ
    Hüttinger, KJ
    CARBON, 2003, 41 (08) : 1501 - 1508
  • [43] Influence of the inlet air in efficiency of photocatalytic devices for mineralization of VOCs in air-conditioning installations
    E. Jimenez-Relinque
    M. Castellote
    Environmental Science and Pollution Research, 2014, 21 : 11198 - 11207
  • [44] Influence of water contamination in air-conditioning system on indoor air quality and proviting measures
    Zheng, AP
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 220 - 225
  • [45] THE INFLUENCE OF AIR-CONDITIONING SYSTEM AND PRESENCE OF STUDENTS ON THE AEROSOL CONCENTRATION IN THE AUDITORIUM
    Polednik, Bernard
    Dudzinska, Marzenna
    Skwarczynski, Mariusz
    ARCHIVES OF ENVIRONMENTAL PROTECTION, 2009, 35 (04): : 45 - 53
  • [46] Influence of the inlet air in efficiency of photocatalytic devices for mineralization of VOCs in air-conditioning installations
    Jimenez-Relinque, E.
    Castellote, M.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (19) : 11198 - 11207
  • [47] The Influence of Air-Conditioning Operating Schedule and Ventilation needs on Energy Consumption
    Todorovic, Maja
    Zivkovic, Branislav
    FME TRANSACTIONS, 2005, 33 (03): : 151 - 155
  • [48] Influence of air-conditioning outdoor unit arrangement strategy on energy consumption
    Duan, Ran
    Wang, Xin
    Song, Yue
    Liu, Jiagen
    8TH INTERNATIONAL COLD CLIMATE HVAC CONFERENCE, 2016, 146 : 349 - 357
  • [49] Study on sleep environment by difference of air-conditioning in summer: Influence of total heat exchange type whole-house air-conditioning ventilation system
    Iwaki A.
    Akimoto T.
    Furuhashi T.
    1600, Architectural Institute of Japan (85): : 871 - 880
  • [50] Effects of air temperature and humidity on particle deposition in a ventilation duct
    Han, Yun-Long
    Hu, Yong-Mei
    Qian, Fu-Ping
    Tumu Jianzhu yu Huanjing Gongcheng/Journal of Civil, Architectural and Environmental Engineering, 2010, 32 (04): : 66 - 70