A system for MRI-guided transperineal delivery of needles to the prostate for focal therapy

被引:32
|
作者
Cepek, Jeremy [1 ,2 ]
Chronik, Blaine A. [1 ,3 ]
Lindner, Uri [4 ]
Trachtenberg, John [4 ]
Davidson, Sean R. H. [5 ]
Bax, Jeffrey [6 ]
Fenster, Aaron [1 ,2 ]
机构
[1] John P Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, London, ON N6A 5B9, Canada
[3] Univ Western Ontario, Dept Phys & Astron, London, ON N6A 3K7, Canada
[4] Univ Hlth Network, Dept Surg Oncol, Div Urol, Toronto, ON M5G 2C4, Canada
[5] Univ Hlth Network, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[6] Ctr Imaging Technol Commercializat, London, ON N6G 4X8, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
MRI-guided; prostate cancer; focal therapy; laser ablation; needle guidance; RADICAL PROSTATECTOMY; CANCER; PHANTOM; ROBOT; BIOPSY; INTERVENTION; ACCURACY; DESIGN; DEATH; RISK;
D O I
10.1118/1.4773043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate the capabilities of a new magnetic resonance imaging (MRI)-guided system for delivering needles to the prostate for focal therapy. Included is a presentation of the design of the system and its user interface, evaluation of MR-compatibility, and quantitative evaluation of guidance accuracy and repeatability within the bore of a clinical MRI scanner. Methods: The use of MRI for visualization of tumors, intraoperative visualization of interventional tools, and thermometry for controlled ablation of lesions is becoming increasingly prevalent. In this work, the authors present a prototype system for guiding needles to prostate tumors within the bore of an MRI scanner for use in focal laser thermal ablation of prostate tumors. The system consists of a manually actuated trajectory alignment device that allows a physician to precisely align a set of needle guides with an intended target in the prostate within the bore of a clinical closed-bore MRI scanner. Needle insertion is then performed transperineally, with the patient in the bore of the MRI, and custom software provides monitoring of thermal ablative procedures. Results: The system is shown to have a minimal effect on image distortion, and only a 6% decrease in image signal-to-noise ratio. Through needle insertion tests in tissue-mimicking phantoms, the system's potential for reliably guiding needles to intra-MR targets within 2.64 mm has been demonstrated. Use of the system to deliver focal laser ablation therapy to two patients showed that it can be used to deliver needles with minimal disruption of workflow, and in less time than when insertions are performed freehand or with a fixed grid template. Conclusions: A system for delivering needles to a patient's prostate for focal therapy within the bore of an MRI scanner has been developed. Results from needle insertion tests in phantoms suggest that the system has the potential to provide accurate delivery of focal therapy to prostate tumors of the smallest clinically significant size. Initial tests in two patients showed that needle deflection was larger than in phantoms, but methods of manually compensating for this effect were employed and needles were delivered to treatment sites with sufficient accuracy to deliver effective treatment. In addition, the treatment was delivered in less time than with a fixed grid template or freehand insertions. Despite this success, methods of reducing needle deflection are needed in order to fully utilize the potential of this system, and further reduce total procedure time. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4773043]
引用
收藏
页数:15
相关论文
共 50 条
  • [41] MRI-guided laser thermal therapy in the prostate: Preliminary results
    McNichols, RJ
    Gowda, A
    Stafford, RJ
    Price, RE
    Hazle, JD
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS XIV, 2004, 5312 : 94 - 104
  • [42] A system for MRI-guided thermal therapy of prostate disease with transurethral ultrasound heating applicators
    Chopra, R
    Choy, V
    Baker, S
    Tang, K
    Boyes, A
    Bronskill, M
    MEDICAL PHYSICS, 2005, 32 (07) : 2422 - 2422
  • [43] In-bore setup and software for 3T MRI-guided transperineal prostate biopsy
    Tokuda, Junichi
    Tuncali, Kemal
    Iordachita, Iulian
    Song, Sang-Eun
    Fedorov, Andriy
    Oguro, Sota
    Lasso, Andras
    Fennessy, Fiona M.
    Tempany, Clare M.
    Hata, Nobuhiko
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (18): : 5823 - 5840
  • [44] MRI-GUIDED FOCAL SALVAGE HDR BRACHYTHERAPY FOR LOCALLY RECURRENT PROSTATE CANCER
    Joseph, Lisa
    Beiki-Ardakani, Akbar
    Weersink, Robert
    Rink, Alexandra
    Lao, Bernadeth
    Warde, Padraig
    Catton, Charles
    Bayley, Andrew
    Menard, Cynthia
    Helou, Joelle
    Berlin, Alejandro
    Sundaramurthy, Aravind
    Chung, Peter
    RADIOTHERAPY AND ONCOLOGY, 2019, 139 : S6 - S6
  • [45] A Pneumatic Driven MRI-Guided Robot System for Prostate Interventions
    Liang, Haipeng
    Zuo, Wanli
    Kessler, Dimitri
    Barrett, Tristan
    Tse, Zion Tsz Ho
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2024, 6 (03): : 951 - 960
  • [46] Dual-frequency ultrasound focal therapy for MRI-Guided transurethral treatment of the prostate: study in gel phantom
    N'Djin, W. Apoutou
    Mougenot, Charles
    Kobelevskiy, Ilya
    Ramsay, Elizabeth
    Bronskill, Michael
    Chopra, Rajiv
    12TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1503 : 212 - 216
  • [47] MRI-guided gene therapy
    Atalar, E.
    Yang, X.
    FEBS JOURNAL, 2006, 273 : 30 - 30
  • [48] MRI-Guided Radiation Therapy
    Jaffray, D.
    Mutic, S.
    Fallone, B.
    Raaymakers, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [49] MRI-guided gene therapy
    Yang, Xiaoming
    Atalar, Ergin
    FEBS LETTERS, 2006, 580 (12) : 2958 - 2961
  • [50] Development of An Irradiation System for MRI-Guided Proton Therapy
    Fujii, Y.
    Ueda, H.
    Takayanagi, T.
    Umegaki, K.
    Matsuura, T.
    MEDICAL PHYSICS, 2021, 48 (06)