Supervisory circuits in a mixed neutron and gamma radiation environment

被引:0
|
作者
Zong, Y [1 ]
Franco, FJ [1 ]
Cachero, AH [1 ]
Agapito, JA [1 ]
Fernandes, AC [1 ]
Marques, JG [1 ]
Rodríguez-Ruiz, MA [1 ]
Casas-Cubillos, J [1 ]
机构
[1] Univ Complutense Madrid, Dep Fis Aplicada 3, Fac CC Fis, Madrid 28040, Spain
来源
NSREC: 2005 IEEE RADIATION EFFECTS DATA WORKSHOP, WORKSHOP RECORD | 2005年
关键词
COTS; supervisory circuits; TID;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This paper describes the evolution of different commercial microprocessor supervisory circuits under neutron and gamma radiation. After the irradiation, the tested devices showed some interesting changes: an increase of supply current and the period of watchdog timer. It was also observed that threshold voltage hysteresis and the shift of TTL trigger level appeared in some devices.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [41] EFFECT OF GAMMA AND NEUTRON RADIATION ON DRUGS
    SCHULTE, KE
    HENKE, G
    ARCHIV DER PHARMAZIE, 1973, 306 (03) : 182 - 197
  • [42] DEVICE FOR MEASURING ABSORBED DOSES OF FAST-NEUTRONS AND GAMMA-RADIATION IN MIXED GAMMA-NEUTRON FIELDS
    BREGADZE, YI
    KARLASHC.VI
    MASLYAEV, PF
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (04): : 255 - 255
  • [43] Interactions between Endothelial Cells and T Cells Modulate Responses to Mixed Neutron/Gamma Radiation
    Cary, Lynnette H.
    Noutai, Daniel
    Salber, Rudolph E.
    Williams, Margaret S.
    Ngudiankama, Barbara F.
    Whitnall, Mark H.
    RADIATION RESEARCH, 2014, 181 (06) : 592 - 604
  • [44] Franco-Russian comparison of mixed neutron and gamma radiation field dosimeters at the Silene reactor
    Gaillard-Lecanu, E
    Chau, Q
    Trompier, F
    Tcvetkov, VI
    Tarasova, EY
    Klechtchenko, ED
    RADIATION MEASUREMENTS, 2001, 33 (06) : 859 - 866
  • [46] A new integrated neutron/gamma radioisotope identification device evaluated under mixed radiation fields
    Ivan, Adrian
    Clothier, Brent A.
    McDevitt, Daniel B.
    Williams, James
    OPTICS AND PHOTONICS IN GLOBAL HOMELAND SECURITY IV, 2008, 6945
  • [47] TRANSIENT RADIATION-INDUCED ELECTRICAL-CONDUCTIVITY OF POLYMERS IN MIXED GAMMA AND NEUTRON FLUXES
    DUNAEV, AF
    TYUTNEV, AL
    SAENKO, VS
    MAKEEV, SN
    FILATOV, NI
    POZHIDAEV, ED
    HIGH ENERGY CHEMISTRY, 1993, 27 (04) : 265 - 268
  • [48] Evaluation of Distributed OFDR-Based Sensing Performance in Mixed Neutron/Gamma Radiation Environments
    Rizzolo, S.
    Boukenter, A.
    Marin, E.
    Robin, T.
    Cannas, M.
    Morana, A.
    Perisse, J.
    Mace, J-R
    Ouerdane, Y.
    Nacir, B.
    Paillet, P.
    Marcandella, C.
    Gaillardin, M.
    Girard, S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (01) : 61 - 67
  • [49] A HEXAFLUOROBENZENE GAMMA DOSIMETER FOR USE IN MIXED NEUTRON AND GAMMA FIELDS
    WAIT, GD
    NUCLEAR APPLICATIONS, 1968, 4 (06): : 440 - +
  • [50] Neutron activation analysis, gamma ray spectrometry and radiation environment monitoring instrument concept: GEORAD
    Ambrosi, RM
    Talboys, DL
    Sims, MR
    Bannister, NP
    Makarewicz, M
    Stevenson, T
    Hutchinson, IB
    Watterson, JIW
    Lanza, RC
    Richter, L
    Mills, A
    Fraser, GW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 539 (1-2): : 198 - 216