dysphagia;
esophageal surgery;
long term;
stent;
EXPANDABLE METAL STENTS;
MALIGNANT ESOPHAGEAL;
ULTRAFLEX STENT;
PALLIATION;
CARCINOMA;
TRIAL;
PERFORATIONS;
STRICTURES;
MANAGEMENT;
PLACEMENT;
D O I:
10.1111/j.1442-2050.2012.01337.x
中图分类号:
R57 [消化系及腹部疾病];
学科分类号:
摘要:
Esophageal stenting with self-expanding plastic or covered metal stents is believed to be safe and effective. As data on the outcome of patients with long-term stenting are not available, this study was conducted to evaluate the safety and efficacy of long-term esophageal stenting. From 2002 to 2008, 70 patients with long-term esophageal stenting for various indications from a prospective database were included into further analysis. The median stent period was 297 (1241980) days during a mean follow-up time of 55 +/- 52.4 months. Overall complication rate was 30% with a primary success rate of 97.2%. The stent-related total reintervention rate was 17.1%. There were no correlations between stent characteristics and the risk of complication or migration. No stent-related death was observed. Our data provide evidence that long-period esophageal stenting is safe and effective for various indications.