Predictive Value and Safety of Intraoperative Neurophysiological Monitoring With Motor Evoked Potentials in Glioma Surgery

被引:116
|
作者
Krieg, Sandro M. [1 ]
Shiban, Ehab [1 ]
Droese, Doris [2 ]
Gempt, Jens [1 ]
Buchmann, Niels [1 ]
Pape, Haiko [1 ]
Ryang, Yu-Mi [1 ]
Meyer, Bernhard [1 ]
Ringel, Florian [1 ]
机构
[1] Tech Univ Munich, Dept Neurosurg, D-81675 Munich, Germany
[2] Tech Univ Munich, Dept Anesthesiol, D-81675 Munich, Germany
关键词
Glioma surgery; Intraoperative neuromonitoring; Motor evoked potentials; Neurological deficit; Neurophysiology; STIMULATION; CORTEX; ANESTHESIA; RESECTION; PATHWAYS; SURVIVAL; IMPACT;
D O I
10.1227/NEU.0b013e31823f5ade
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Resection of gliomas in or adjacent to the motor system is widely performed with intraoperative neuromonitoring (IOM). Despite the fact that data on the safety of IOM are available, the significance and predictive value of the procedure are still under discussion. Moreover, cases of false-negative monitoring affect the surgeon's confidence in IOM. OBJECTIVE: To examine cases of false-negative IOM to reveal structural explanations. METHODS: Between 2007 and 2010, we resected 115 consecutive supratentorial gliomas in or close to eloquent motor areas using direct cortical stimulation for monitoring of motor evoked potentials (MEPs). The monitoring data were reviewed and related to new postoperative motor deficit and postoperative imaging. Clinical outcomes were assessed during follow-up. RESULTS: Monitoring of MEPs was successful in 112 cases (97.4%). Postoperatively, 30.3% of patients had a new motor deficit, which remained permanent in 12.5%. Progression-free follow-up was 9.7 months (range, 2 weeks-40.6 months). In 65.2% of all cases, MEPs were stable throughout the operation, but 8.9% showed a new temporary motor deficit, whereas 4.5% (5 patients) presented with permanently deteriorated motor function representing false-negative monitoring at first glance. However, these cases were caused by secondary hemorrhage, ischemia, or resection of the supplementary motor area. CONCLUSION: Continuous MEP monitoring provides reliable monitoring of the motor system, influences the course of operation in some cases, and has to be regarded as the standard for IOM of the motor system. In our series, we found no false-negative MEP results.
引用
收藏
页码:1060 / 1070
页数:11
相关论文
共 50 条
  • [21] The value of intraoperative neurophysiological monitoring in tethered cord surgery
    Eelco W. Hoving
    Esther Haitsma
    Charlotte M. C. Oude Ophuis
    Henricus L. Journée
    Child's Nervous System, 2011, 27 : 1445 - 1452
  • [22] INTRAOPERATIVE MONITORING OF MOTOR FUNCTION BY MAGNETIC MOTOR EVOKED-POTENTIALS
    LEE, WY
    HOU, WY
    YANG, LH
    LIN, SM
    NEUROSURGERY, 1995, 36 (03) : 493 - 500
  • [23] Intraoperative motor evoked potentials
    Isley, MR
    Balzer, JR
    Pearlman, RC
    Zhang, XF
    AMERICAN JOURNAL OF ELECTRONEURODIAGNOSTIC TECHNOLOGY, 2001, 41 (04): : 266 - 338
  • [24] Facial motor evoked potentials in cerebellopontine angle surgery: Technique, pitfalls and predictive value
    Matthies, Cordula
    Raslan, Furat
    Schweitzer, Tilman
    Hagen, Rudolf
    Roosen, Klaus
    Reiners, Karlheinz
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2011, 113 (10) : 872 - 879
  • [25] Intraoperative motor evoked potential monitoring - A position statement by the American Society of Neurophysiological Monitoring
    MacDonald, D. B.
    Skinner, S.
    Shils, J.
    Yingling, C.
    CLINICAL NEUROPHYSIOLOGY, 2013, 124 (12) : 2291 - 2316
  • [26] NEW INTRAOPERATIVE MONITORING OF CORTICOBULBAR MOTOR EVOKED POTENTIALS IN CHILDREN
    Bozinov, O.
    Sarnthein, J.
    PEDIATRIC BLOOD & CANCER, 2014, 61 : S136 - S137
  • [27] Monitoring intraoperative motor-evoked potentials in a pregnant patient
    Manohar, Nitin
    Palan, Astha
    Manchala, Ravi Kumar
    Manjunath, S. T.
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (02) : 142 - +
  • [28] Intraoperative monitoring of motor evoked potentials: A review of 116 cases
    Nagle, KJ
    Emerson, RG
    Adams, DC
    Heyer, EJ
    Roye, DP
    Schwab, FJ
    Weidenbaum, M
    McCormick, P
    PileSpellman, J
    Stein, BM
    Farcy, JP
    Gallo, EJ
    Dowling, KC
    Turner, CA
    NEUROLOGY, 1996, 47 (04) : 999 - 1004
  • [29] Utility of Motor Evoked Potentials for Intraoperative Nerve Root Monitoring
    MacDonald, David B.
    Stigsby, Bent
    Al Homoud, Iftetah
    Abalkhail, Tariq
    Mokeem, Amal
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2012, 29 (02) : 118 - 125