A new anti-neutrino detection technique based on positronium tagging with plastic scintillators

被引:2
|
作者
Consolati, G. [1 ]
Franco, D. [2 ]
Jollet, C. [3 ]
Meregaglia, A. [3 ]
Minotti, A. [3 ]
Perasso, S. [2 ]
Tonazzo, A. [2 ]
机构
[1] Politecn Milan, Dept Aerosp Sci & Technol, I-20156 Milan, Italy
[2] Univ Paris Diderot, CEA Irfu, Sorbonne Paris Cite, CNRS,IN2P3,APC,Obs Paris, F-75205 Paris, France
[3] Univ Strasbourg, CNRS, IN2P3, IPHC, F-67037 Strasbourg, France
关键词
Neutrino; Reactor; Posittonium; Detector; FISSION-PRODUCTS; SPECTRA; PU-239;
D O I
10.1016/j.nima.2015.06.021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The main signature for anti-neutrino detection in reactor and geo-neutrino experiments based on scintillators is provided by the space-time coincidence of positron and neutron produced in the Inverse Beta Decay reaction. Such a signature strongly suppresses backgrounds and allows for measurements performed underground with a relatively high signal-to-background ratio. In an aboveground environment, however, the twofold coincidence technique is not sufficient to efficiently reject the high background rate induced by cosmogenic events. Enhancing the positron-neutron twofold coincidence efficiency may pave the way to future aboveground detectors for reactor monitoring. We propose a new detection scheme based on a threefold coincidence, among the positron ionization, the ortho-positronium (o-Ps) decay, and the neutron capture, in a sandwich detector with alternated layers of plastic scintillator and aerogel powder. We present the results of a set of dedicated measurements on the achievable light yield and on the o-Ps formation and lifetime. The efficiencies for signal detection and background rejection of a preliminary detector design are also discussed. (C) 2015 Elsevier B.V. All rights reserved
引用
收藏
页码:364 / 369
页数:6
相关论文
共 50 条
  • [21] New Results from MiniBooNE Charged-Current Quasi-Elastic Anti-Neutrino Data
    Grange, Joseph
    NUINT11: THE 7TH INTERNATIONAL WORKSHOP ON NEUTRINO-NUCLEUS INTERACTIONS IN THE FEW GEV REGION, 2011, 1405
  • [22] A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
    D. Kamińska
    A. Gajos
    E. Czerwiński
    D. Alfs
    T. Bednarski
    P. Białas
    C. Curceanu
    K. Dulski
    B. Głowacz
    N. Gupta-Sharma
    M. Gorgol
    B. C. Hiesmayr
    B. Jasińska
    G. Korcyl
    P. Kowalski
    W. Krzemień
    N. Krawczyk
    E. Kubicz
    M. Mohammed
    Sz. Niedźwiecki
    M. Pawlik-Niedźwiecka
    L. Raczyński
    Z. Rudy
    M. Silarski
    A. Wieczorek
    W. Wiślicki
    B. Zgardzińska
    M. Zieliński
    P. Moskal
    The European Physical Journal C, 2016, 76
  • [23] A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
    Kaminska, D.
    Gajos, A.
    Czerwinski, E.
    Alfs, D.
    Bednarski, T.
    Bialas, P.
    Curceanu, C.
    Dulski, K.
    Glowacz, B.
    Gupta-Sharma, N.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Korcyl, G.
    Kowalski, P.
    Krzemien, W.
    Krawczyk, N.
    Kubicz, E.
    Mohammed, M.
    Niedzwiecki, Sz.
    Pawlik-Niedzwiecka, M.
    Raczynski, L.
    Rudy, Z.
    Silarski, M.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    EUROPEAN PHYSICAL JOURNAL C, 2016, 76 (08):
  • [24] Lead Halide perovskite based plastic scintillators for alpha particle detection
    Chhangani, Sumit
    Kumar, Monu
    Sahani, R. M.
    Bera, Anuradha
    Pandya, Arun
    MATERIALS TODAY COMMUNICATIONS, 2022, 33
  • [25] Detection and discrimination of α- and β-radiation with plastic scintillators based on pulse shape discrimination
    Zhang, Z. H.
    Zhang, Y. F.
    Hu, C. Y.
    Feng, S.
    Zhu, J. J.
    Liao, B.
    Liu, D. K.
    Zhou, Q.
    Wang, H. R.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (04):
  • [26] Evaluation of a new position sensitive detector based on the plastic rod scintillators
    Peyvandi, R. G.
    Taheri, A.
    Lehdarboni, M. A.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [27] A new-concept calorimeter for future neutrino beams based on Kaon tagging
    Longhin, A.
    Ludovici, L.
    Terranova, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 693 - 694
  • [28] Crosslinked plastic scintillators: A new detection system for radioactivity measurement in organic and aggressive media
    Bagan, Hector
    Tarancon, Alex
    Ye, Lei
    Garcia, Jose F.
    ANALYTICA CHIMICA ACTA, 2014, 852 : 13 - 19
  • [29] Characterization and performance evaluation of epoxy-based plastic scintillators for gamma ray detection
    Pancoko, Marliyadi
    Nuri, Hafni L.
    Prasetyo, Andjar
    Manaf, Azwar
    Jami, Abdul
    Yanto, Ausatha R.
    Kasmudin
    Djokorayono, Rony
    Suntoro, Achmad
    FRONTIERS IN PHYSICS, 2024, 12
  • [30] Measurement of the proton light response of various LAB based scintillators and its implication for supernova neutrino detection via neutrino–proton scattering
    B. von Krosigk
    L. Neumann
    R. Nolte
    S. Röttger
    K. Zuber
    The European Physical Journal C, 2013, 73