Electrocatalytical oxidation and sensitive determination of acetaminophen on glassy carbon electrode modified with graphene-chitosan composite

被引:84
|
作者
Zheng, Meixia [1 ]
Gao, Feng [1 ]
Wang, Qingxiang [1 ]
Cai, Xili [1 ]
Jiang, Shulian [2 ]
Huang, Lizhang [2 ]
Gao, Fei [1 ]
机构
[1] Zhangzhou Normal Univ, Dept Chem & Environm Sci, Zhangzhou 363000, Peoples R China
[2] Zhangzhou Prod Qual Supervis & Inspect Inst, Zhangzhou 363000, Peoples R China
关键词
Graphene-chitosan composite; Acetaminophen; Electrochemistry; Determination; ELECTROCHEMICAL-BEHAVIOR; GLUCOSE-OXIDASE; NANOPARTICLES; PARACETAMOL; SENSOR; NANOTUBES; SAMPLES; FILM; DNA;
D O I
10.1016/j.msec.2012.12.055
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The electrochemical behaviors of acetaminophen (ACOP) on a graphene-chitosan (GR-CS) nanocomposite modified glassy carbon electrode (GCE) were investigated by cyclic voltammetry (CV), chronocoulometry (CC) and differential pulse voltammetry (DPV). Electrochemical characterization showed that the GR-CS nanocomposite had excellent electrocatalytic activity and surface area effect. As compared with bare GCE, the redox signal of ACOP on GR-CS/GCE was greatly enhanced. The values of electron transfer rate constant (k(s)), diffusion coefficient (D) and the surface adsorption amount (I*) of ACOP on GR-CS/GCE were determined to be 025 s(-1), 3.61 x 10(-5) cm(2) s(-1) and 1.09 x 10(-9) mol cm(-2), respectively. Additionally, a 2e(-)/2H(+) electrochemical reaction mechanism of ACOP was deduced based on the acidity experiment. Under the optimized conditions, the ACOP could be quantified in the range from 1.0 x 10(-6) to 1.0 x 10(-4) M with a low detection limit of 3.0 x 10(-7) M based on 3S/N. The interference and recovery experiments further showed that the proposed method is acceptable for the determination of ACOP in real pharmaceutical preparations. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1514 / 1520
页数:7
相关论文
共 50 条
  • [31] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984
  • [32] Sensitive Voltammetric Determination of Acetaminophen at Poly(4-vinyl pyridine)/Graphene Composite Modified Electrode
    Tehrani, R. M. A.
    Ghadimi, H.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2016, 3 (01): : 111 - 121
  • [33] Simultaneous Electrochemical Determination of Sulphite and Nnitrite Using a Gold Nanoparticle/Graphene-Chitosan Modified Electrode
    Wang Xue
    Li Hui
    Wu Min
    Ge Shu-Li
    Zhu Yan
    Wang Qing-Jiang
    He Ping-Gang
    Fang Yu-Zhi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (08) : 1232 - 1237
  • [34] Study and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode
    Behpour, M.
    Masoum, S.
    Meshki, M.
    JOURNAL OF NANOSTRUCTURES, 2013, 3 (02) : 243 - 251
  • [35] Electrochemical Determination of Tyrosine Using Graphene and Gold Nanoparticle Composite Modified Glassy Carbon Electrode
    Liu, M.
    Lao, J.
    Wang, H.
    Xu, Z.
    Li, J.
    Wen, L.
    Yin, Z.
    Luo, C.
    Peng, H.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2021, 57 (01) : 41 - 50
  • [36] Electrochemical Determination of Tyrosine Using Graphene and Gold Nanoparticle Composite Modified Glassy Carbon Electrode
    M. Liu
    J. Lao
    H. Wang
    Z. Xu
    J. Li
    L. Wen
    Z. Yin
    C. Luo
    H. Peng
    Russian Journal of Electrochemistry, 2021, 57 : 41 - 50
  • [37] Electrochemical Determination of Morin in Natural Food Using a Chitosan-Graphene Glassy Carbon Modified Electrode
    Nagles, Edgar
    Bello, Monica
    Hurtado, John J.
    SENSORS, 2022, 22 (20)
  • [38] A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotube/Chitosan Composite as a New Sensor for Simultaneous Determination of Acetaminophen and Mefenamic Acid in Pharmaceutical Preparations and Biological Samples
    Babaei, Ali
    Afrasiabi, Mohammad
    Babazadeh, Mitra
    ELECTROANALYSIS, 2010, 22 (15) : 1743 - 1749
  • [39] Determination of Trace Thiocyanate by a Chitosan-Modified Glassy Carbon Electrode
    LU Guang han 1**
    2. Department of Chemistry
    Chemical Research in Chinese Universities, 2002, (03) : 316 - 320
  • [40] Determination of the total iron by chitosan-modified glassy carbon electrode
    Lu, GH
    Yao, X
    Wu, XG
    Zhan, T
    MICROCHEMICAL JOURNAL, 2001, 69 (01) : 81 - 87