摘要
As compared to pinholes and collimators, coded aperture cameras present the potential advantage of increased signal-to-noise ratio (SNR). This advantage can be used to improve the resolution of conventional imagers while still producing clear images. In this paper, we describe a near-field coded aperture camera with a field of view of 9 x 9 cm and 1.7-mm system resolution based on the use of an existing gamma-camera. Experimental results include planar in-vivo studies of Tc-99m-labeled compounds in a mouse.
引用
收藏
页码:2411 / 2417
页数:7
相关论文
共 50 条
  • [31] Design of coded aperture collimator for high-resolution & high-sensitivity MicroSPECT
    Jiang, SZ
    Wu, ZX
    Ma, TY
    Jin, YJ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2980 - 2984
  • [32] A HIGH-RESOLUTION OPTICAL SCANNER FOR DIGITIZING SCINTIPHOTOS OF ANGER SCINTILLATION CAMERA
    LORENZ, WJ
    MEDER, HG
    JOURNAL OF NUCLEAR MEDICINE, 1970, 11 (10) : 635 - &
  • [33] High-resolution 125I small animal imaging with a coded aperture and a hybrid pixel detector
    Accorsi, Roberto
    Celentano, Luigi
    Laccetti, Paolo
    Lanza, Richard C.
    Marotta, Marcello
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Roberti, Giuseppe
    Russo, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (01) : 481 - 490
  • [34] Near-field high-resolution coded aperture gamma-ray imaging with separable masks
    Sun, Shifeng
    Liu, Yang
    Ouyang, Xiaoping
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 951 (951):
  • [35] Three-dimensional coded aperture techniques in diagnostic nuclear medicine imaging
    Zhang, L
    Lanza, RC
    Hom, BKP
    Zimmerman, RE
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 364 - 373
  • [36] SMALL-SIGNAL SUPPRESSION IN CODED APERTURE IMAGING IN NUCLEAR-MEDICINE
    HOULE, S
    JOY, MLG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 369 - 373
  • [37] ADVANCED CODED-APERTURE IMAGING-SYSTEM FOR NUCLEAR-MEDICINE
    OHYAMA, N
    HONDA, T
    TSUJIUCHI, J
    MATUMOTO, T
    IINUMA, TA
    ISHIMATSU, K
    APPLIED OPTICS, 1983, 22 (22): : 3555 - 3561
  • [38] An Instrument Concept for High-Resolution Observations of the Solar Wind Electron Strahl Using Coded Aperture Imaging
    Reid, Riley A.
    Marshall, Robert
    EARTH AND SPACE SCIENCE, 2025, 12 (03)
  • [39] ANALOG DECONVOLUTION IN CODED-APERTURE IMAGING APPLIED TO NUCLEAR-MEDICINE
    BRUNOL, J
    FONROGET, Y
    LOWENTHAL, S
    OPTICA ACTA, 1978, 25 (02): : 113 - 124
  • [40] High-resolution multispectral imaging with random coded exposure
    Gao, Dahua
    Liu, Danhua
    Xie, Xuemei
    Wu, Xiaolin
    Shi, Guangming
    JOURNAL OF APPLIED REMOTE SENSING, 2013, 7