A coded aperture for high-resolution nuclear medicine planar imaging with a conventional anger camera: Experimental results

被引:0
|
作者
Accorsi, R [1 ]
Gasparini, F
Lanza, RC
机构
[1] MIT, Dept Nucl Engn, Cambridge, MA 02139 USA
[2] Politecn Milan, Dipartimento Ingn Nucl, I-20133 Milan, Italy
关键词
coded aperture imaging; high resolution; molecular imaging; nuclear medicine imaging; small animal imaging;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As compared to pinholes and collimators, coded aperture cameras present the potential advantage of increased signal-to-noise ratio (SNR). This advantage can be used to improve the resolution of conventional imagers while still producing clear images. In this paper, we describe a near-field coded aperture camera with a field of view of 9 x 9 cm and 1.7-mm system resolution based on the use of an existing gamma-camera. Experimental results include planar in-vivo studies of Tc-99m-labeled compounds in a mouse.
引用
收藏
页码:2411 / 2417
页数:7
相关论文
共 50 条
  • [1] A coded aperture for high-resolution nuclear medicine planar imaging with a conventional anger camera: Experimental results
    Accorsi, R
    Schellingerhout, D
    Idoine, J
    Lanza, RC
    Weissleder, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1587 - 1591
  • [2] HICAM: development of a high-resolution Anger Camera for Nuclear Medicine
    Fiorini, C.
    Gola, A.
    Peloso, R.
    Geraci, A.
    Longoni, A.
    Padovini, G.
    Lechner, P.
    Strueder, L.
    Hutton, B. F.
    Erlandsson, K.
    Mahmood, S.
    Van Mullekom, P.
    Pedretti, A.
    Moretti, R.
    Poli, G. L.
    Lucignani, G.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3236 - +
  • [3] High-transparency coded apertures in planar nuclear medicine imaging: Experimental results
    Starfield, David M.
    Rubin, David M.
    Marwala, Tshilidzi
    Keddy, Rex J.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3151 - +
  • [4] Sampling Considerations and Resolution Enhancement in Ideal Planar Coded Aperture Nuclear Medicine Imaging
    Starfield, D. M.
    Rubin, D. M.
    Marwala, T.
    11TH MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2007, VOLS 1 AND 2, 2007, 16 (1-2): : 806 - +
  • [5] High-resolution imaging using a translating coded aperture
    Mahalanobis, Abhijit
    Shilling, Richard
    Muise, Robert
    Neifeld, Mark
    OPTICAL ENGINEERING, 2017, 56 (08)
  • [6] Monte Carlo and experimental evaluation of a Timepix4 compact gamma camera for coded aperture nuclear medicine imaging with depth resolution
    Cerbone, Laura Antonia
    Cimmino, Luigi
    Sarno, Antonio
    Biesuz, Nicolo Vladi
    Bolzonella, Riccardo
    Mettivier, Giovanni
    Fiorini, Massimiliano
    Russo, Paolo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 113
  • [7] Complementary coded aperture set for compressive high-resolution imaging
    Sun, Wei
    Sun, Jinqiu
    Zhu, Yu
    Hu, Yaoqi
    Ding, Chen
    Li, Haisen
    Zhang, Yanning
    NEUROCOMPUTING, 2019, 358 : 177 - 187
  • [8] Single pinhole and coded aperture collimation systems for high-resolution gamma-ray imaging in nuclear medicine: a comparative study
    Fiorini, C.
    Accorsi, R.
    Lucignani, G.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2938 - 2941
  • [9] High transparency coded apertures in planar nuclear medicine imaging
    Starfield, David M.
    Rubin, David M.
    Marwala, Tshilidzi
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4468 - +
  • [10] Toward High-Resolution Face Image Generation From Coded Aperture Camera
    Shahreza, Hatef Otroshi
    Veuthey, Alexandre
    Marcel, Sebastien
    IEEE SENSORS LETTERS, 2023, 7 (11)