共 27 条
Hardware-Based Cascaded Topology and Modulation Strategy With Leakage Current Reduction for Transformerless PV Systems
被引:142
作者:
Guo, Xiaoqiang
[1
]
Jia, Xiaoyu
[1
]
机构:
[1] Yanshan Univ, Key Lab Power Elect Energy Conservat & Motor Driv, Dept Elect Engn, Qinhuang Dao 066004, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Cascaded H-bridge inverter;
leakage current;
pulse width modulation;
transformerless photovoltaic system;
MULTILEVEL-INVERTER;
REDUCED NUMBER;
SUPPRESSION;
D O I:
10.1109/TIE.2016.2607163
中图分类号:
TP [自动化技术、计算机技术];
学科分类号:
0812 ;
摘要:
Leakage current reduction of the single-phase transformerless cascaded H-bridge PV inverter is investigated in this paper. The high-frequency common-mode loop model of a typical single-phase cascaded H-bridge PV system is established. Based on the model, the main factors that affect the leakage current are discussed. The reason why the typical single-phase cascaded H-bridge inverter fails to reduce the leakage current is explained. In order to solve the problem, a cascaded topology based on the H5 inverter is presented, along with a new modulation strategy, which can ensure that the stray capacitor voltage is free of high-frequency components. In this way, the leakage current can be effectively reduced. Finally, a prototype with TMS320F28335DSP+XC3S400FPGA digital control is built. The performance tests of cascaded H-bridge and the proposed topologies are carried out. The experimental results verify the effectiveness of the proposed solution.
引用
收藏
页码:7823 / 7832
页数:10
相关论文