Radiation dose in cardiac CT angiography: protocols and image quality

被引:6
|
作者
Oliveira, L. C. G. [1 ]
Gottlieb, I. [2 ]
Rizzi, P. [2 ]
Lopes, R. T. [1 ]
Kodlulovich, S. [3 ]
机构
[1] Univ Fed Rio de Janeiro, COPPE, LIN, Ctr Tecnol,Ilha Fundao, BR-21949900 Rio de Janeiro, RJ, Brazil
[2] Clin Diagnost Imagem CDPI, BR-22649900 Rio De Janeiro, RJ, Brazil
[3] CNEN, IRD, BR-22780160 Rio De Janeiro, RJ, Brazil
关键词
NONINVASIVE CORONARY-ANGIOGRAPHY; AXIAL SCANNING TOMOGRAPHY; BODY-MASS INDEX; COMPUTED-TOMOGRAPHY; EXPOSURE; OPTIMIZATION; MODULATION; REDUCTION; RADIOLOGY; IMPACT;
D O I
10.1093/rpd/ncs313
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper aims to evaluate the radiation dose exposure of patients submitted to cardiac computed tomography angiography. The effective dose was obtained from the product of doselength product values and the conversion factor established in the European Working Group for Guidelines on Quality Criteria in CT. The image noise and contrast- and signal-to-noise ratios were obtained for all images. Sixty-four- and 256-slice CT angiographies were used in 211 (68.5 ) and 97 (31.5 ) patients, respectively. The calculated mean effective dose with prospective CT angiography was 6.01.0 mSv and the retrospective mode was 8.41.2 mSv. The mean image noise values were 38.59.5 and 21.4 5.3 for prospective and retrospective modes, respectively. It was observed that the image noise increased by 44.4 using a prospective mode. Prospective CT angiography reduces radiation dose by 29 compared with the retrospective mode, while maintaining diagnostic image quality and the ability to assess obstructions in patients.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 50 条
  • [41] Radiation dose dependence on MDCT platform and acquisition protocols for CT coronary angiography
    Wallace, Anthony B.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (01) : 1 - 3
  • [42] Infant Cardiac CT Angiography with 64-Slice and 256-Slice CT: Comparison of Radiation Dose and Image Quality Using a Pediatric Phantom
    Lee, Yi-Wei
    Yang, Ching-Ching
    Mok, Greta S. P.
    Wu, Tung-Hsin
    PLOS ONE, 2012, 7 (11):
  • [43] Image quality and radiation exposure of low-dose protocols for coronary CT angiography: comparison of prospectively triggered axial scanning and high-pitch spiral CT
    Seltmann, M.
    Achenbach, S.
    Goroll, T.
    Marwan, M.
    Pflederer, T.
    Ropers, D.
    Lell, M.
    Anders, K.
    Uder, M.
    Daniel, W. G.
    EUROPEAN HEART JOURNAL, 2010, 31 : 293 - 293
  • [44] Image Quality in Reduced-Dose Coronary CT Angiography
    Gagarina, Nina V.
    Irwan, Roy
    Gordina, Galina
    Fominykh, Ekaterina
    Sijens, Paul E.
    ACADEMIC RADIOLOGY, 2011, 18 (08) : 984 - 990
  • [45] Low dose sequential and conventional spiral cardiac CT angiography with a hybrid CT-PET-scanner: Image quality and dose comparison
    Kajander, S.
    Ukkonen, H.
    Knuuti, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S150 - S150
  • [46] Effect of reconstruction parameters on cardiac CT angiography image quality
    Greenberg, NL
    Johnson, PC
    Manning, M
    Popovic, Z
    Salazer, H
    Garcia, MJ
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 757 - 760
  • [47] Image Quality and Radiation Exposure Using Different Low-Dose Scan Protocols in Dual-Source CT Coronary Angiography: Randomized Study
    Neefjes, Lisan A.
    Dharampal, Anoeshka S.
    Rossi, Alexia
    Nieman, Koen
    Weustink, Annick C.
    Dijkshoorn, Marcel L.
    ten Kate, Gert-Jan R.
    Dedic, Admir
    Papadopoulou, Stella L.
    van Straten, Marcel
    Cademartiri, Filippo
    Krestin, Gabriel P.
    de Feyter, Pim J.
    Mollet, Nico R.
    RADIOLOGY, 2011, 261 (03) : 779 - 786
  • [48] Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography
    Zhang, Tianle
    Geng, Xue
    Li, Dongxue
    Xu, Yize
    Zhao, Yongxia
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (05)
  • [49] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [50] Pulmonary CT Angiography as First-Line Imaging for PE: Image Quality and Radiation Dose Considerations
    Mayo, John
    Thakur, Yogesh
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (03) : 522 - 528