Voltammetric determination of kojic acid in cosmetic bleaching products using a disposable screen-printed carbon electrode

被引:2
|
作者
Shih, Y [1 ]
Zen, JM
机构
[1] Hung Kuang Inst Technol, Dept Appl Cosmetol, Taichung 433, Taiwan
[2] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
kojic acid; screen-printed electrode; cosmetic bleaching products;
D O I
10.1002/(SICI)1521-4109(199904)11:4<229::AID-ELAN229>3.3.CO;2-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A preanodized screen-printed carbon electrode is used for the determination of kojic acid in cosmetic bleaching products by square-wave voltammetry. The preanodization process leads to a marked enhancement of the current response of kojic acid at the screen-printed carbon electrode. The linear range is up to 260 mu M in pH 10 Britton-Robinson buffer with a detection limit (S/N=3) of 0.17 mu M. The electrode has the advantages of low cost, of being easy to handle, and it can be either disposable or reused since the renewal gives a reproducible surface. Quantitative analysis for the kojic acid content in cosmetic products was performed by the standard addition method.
引用
收藏
页码:229 / 233
页数:5
相关论文
共 50 条
  • [21] Voltammetric determination of ascorbic acid by using a disposable screen printed electrode modified with Cu(OH)2 nanorods
    Raveendran, Jeethu
    Krishnan, Rajasree G.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    MICROCHIMICA ACTA, 2017, 184 (09) : 3573 - 3579
  • [22] Voltammetric determination of ascorbic acid by using a disposable screen printed electrode modified with Cu(OH)2 nanorods
    Jeethu Raveendran
    Rajasree G. Krishnan
    Bipin G. Nair
    T. G. Satheesh Babu
    Microchimica Acta, 2017, 184 : 3573 - 3579
  • [23] Improved anodic stripping voltammetric detection of zinc on a disposable screen-printed gold electrode
    Sarah M. da Silva
    André L. Squissato
    Diego P. Rocha
    Maria L. S. Vasconcellos
    Rafael de Q. Ferreira
    Eduardo M. Richter
    Rodrigo A. A. Munoz
    Ionics, 2020, 26 : 2611 - 2621
  • [24] Disposable screen-printed pH-electrode for determination of anticholinesterase activity
    Koncki, R
    Mascini, M
    BIOSENSORS FOR DIRECT MONITORING OF ENVIRONMENTAL POLLUTANTS IN FIELD, 1997, 38 : 139 - 144
  • [25] Simultaneous voltammetric determination of acetaminophen and isoniazid using MXene modified screen-printed electrode
    Zhang, Yu
    Jiang, Xiantao
    Zhang, Junjie
    Zhang, Han
    Li, Yingchun
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 315 - 321
  • [26] Flow injection analysis of kojic acid in cosmetics by a carbon-nanotube modified screen-printed electrode
    Shih, Ying
    Zen, Jyh-Myng
    Ke, Jyh-Harng
    Hsu, Jaw-Cherng
    Chen, Pei-Chi
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2007, 15 (02) : 151 - 155
  • [27] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Nahid Shoaie
    Mehdi Forouzandeh
    Kobra Omidfar
    Microchimica Acta, 2018, 185
  • [28] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Shoaie, Nahid
    Forouzandeh, Mehdi
    Omidfar, Kobra
    MICROCHIMICA ACTA, 2018, 185 (04)
  • [29] Voltammetric behavior and trace determination of lead at a mercury-free screen-printed carbon electrode
    Honeychurch, KC
    Hart, JP
    Cowell, DC
    ELECTROANALYSIS, 2000, 12 (03) : 171 - 177
  • [30] Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode
    Honeychurch, KC
    Hawkins, DM
    Hart, JP
    Cowell, DC
    TALANTA, 2002, 57 (03) : 565 - 574