Accurate real-time FENO expirograms using complementary optical sensors

被引:6
|
作者
Petralia, Lorenzo S. [1 ]
Bahl, Anisha [1 ]
Peverall, Rob [1 ]
Richmond, Graham [1 ]
Couper, John H. [1 ]
Hancock, Gus [1 ]
Robbins, Peter A. [2 ]
Ritchie, Grant A. D. [1 ]
机构
[1] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, Oxford, England
[2] Univ Oxford, Dept Physiol Anat & Genet, Oxford, England
基金
英国工程与自然科学研究理事会;
关键词
nitric oxide; asthma; two-compartment model; FENO; laser spectroscopy; CEAS; EXHALED NITRIC-OXIDE; CAVITY RING-DOWN; ASTHMA; SPECTROSCOPY; NO; MEPOLIZUMAB; AIR; MANAGEMENT; DIFFUSION; ALVEOLAR;
D O I
10.1088/1752-7163/ab9c31
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fraction of exhaled nitric oxide (FENO) is an important biomarker for the diagnosis and management of asthma and other pulmonary diseases associated with airway inflammation. In this study we report on a novel method for accurate, highly time-resolved, real time detection of FENO at the mouth. The experimental arrangement is based on a combination of optical sensors for the determination of the temporal profile of exhaled NO and CO(2)concentrations. Breath CO(2)and exhalation flow are measured at the mouth using diode laser absorption spectroscopy (at 2 mu m) and differential pressure sensing, respectively. NO is determined in a sidestream configuration using a quantum cascade laser based, cavity-enhanced absorption cell (at 5.2 mu m) which simultaneously measures sidestream CO2. The at-mouth and sidestream CO(2)measurements are used to enable the deconvolution of the sidestream NO measurement back to the at-mouth location. All measurements have a time resolution of 0.1 s, limited by the requirement of a reasonable limit of detection for the NO measurement, which on this timescale is 4.7 ppb (2 sigma). Using this methodology, NO expirograms (F(E)NOgrams) were measured and compared for eight healthy volunteers. The F(E)NOgrams appear to differ qualitatively between individuals and the hope is that the dynamic information encoded in these F(E)NOgrams will provide valuable additional insight into the location of the inflammation in the airways and potentially predict a response to therapy. A validation of the measurements at low-time resolution is provided by checking that results from previous studies that used a two-compartment model of NO production can be reproduced using our technology.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Real-time control of human actions using inertial sensors
    Liu HuaJun
    He FaZhi
    Zhu FuXi
    Zhu Qing
    SCIENCE CHINA-INFORMATION SCIENCES, 2014, 57 (07) : 1 - 11
  • [32] Real-Time Activity Classification Using Ambient and Wearable Sensors
    Atallah, Louis
    Lo, Benny
    Ali, Raza
    King, Rachel
    Yang, Guang-Zhong
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (06): : 1031 - 1039
  • [33] Real-time detection of uncalibrated sensors using neural networks
    Munoz-Molina, Luis J.
    Cazorla-Pinar, Ignacio
    Dominguez-Morales, Juan P.
    Lafuente, Luis
    Perez-Pena, Fernando
    NEURAL COMPUTING & APPLICATIONS, 2022, 34 (10): : 8227 - 8239
  • [34] Real-time activity monitoring using wireless wearable sensors
    Li, HQ
    Wu, JK
    Bao, XM
    Cheng, DL
    Dong, L
    PSC '05: PROCEEDINGS OF THE 2005 INTERNATIONAL CONFERENCE ON PERVASIVE SYSTEMS AND COMPUTING, 2005, : 117 - 123
  • [35] Real-time control of human actions using inertial sensors
    LIU HuaJun
    HE FaZhi
    ZHU FuXi
    ZHU Qing
    Science China(Information Sciences), 2014, 57 (07) : 162 - 172
  • [36] Real-Time Gait Phase Detection Using Wearable Sensors
    Mazhar, Osama
    Bari, Abu Zeeshan
    Faudzi, Ahmad 'Athif Mohd
    2015 10TH ASIAN CONTROL CONFERENCE (ASCC), 2015,
  • [37] Accurate specular reflections in real-time
    Roger, David
    Holzschuch, Nicolas
    COMPUTER GRAPHICS FORUM, 2006, 25 (03) : 293 - 302
  • [38] REAL-TIME LONG-RANGE COMPLEMENTARY CORRELATION OPTICAL-TIME DOMAIN REFLECTOMETER
    NAZARATHY, M
    NEWTON, SA
    GIFFARD, RP
    MOBERLY, DS
    SISCHKA, F
    TRUTNA, WR
    FOSTER, S
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1989, 7 (01) : 24 - 38
  • [39] Real-time optical time interpolation using spectra interferometry
    Fordell, Thomas
    OPTICS LETTERS, 2022, 47 (05) : 1194 - 1197
  • [40] Real-time optical image processing by synthesis of the coherence function using real-time holography
    Okugawa, T
    Hotate, K
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1996, 8 (02) : 257 - 259