Accurate real-time FENO expirograms using complementary optical sensors

被引:6
|
作者
Petralia, Lorenzo S. [1 ]
Bahl, Anisha [1 ]
Peverall, Rob [1 ]
Richmond, Graham [1 ]
Couper, John H. [1 ]
Hancock, Gus [1 ]
Robbins, Peter A. [2 ]
Ritchie, Grant A. D. [1 ]
机构
[1] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, Oxford, England
[2] Univ Oxford, Dept Physiol Anat & Genet, Oxford, England
基金
英国工程与自然科学研究理事会;
关键词
nitric oxide; asthma; two-compartment model; FENO; laser spectroscopy; CEAS; EXHALED NITRIC-OXIDE; CAVITY RING-DOWN; ASTHMA; SPECTROSCOPY; NO; MEPOLIZUMAB; AIR; MANAGEMENT; DIFFUSION; ALVEOLAR;
D O I
10.1088/1752-7163/ab9c31
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fraction of exhaled nitric oxide (FENO) is an important biomarker for the diagnosis and management of asthma and other pulmonary diseases associated with airway inflammation. In this study we report on a novel method for accurate, highly time-resolved, real time detection of FENO at the mouth. The experimental arrangement is based on a combination of optical sensors for the determination of the temporal profile of exhaled NO and CO(2)concentrations. Breath CO(2)and exhalation flow are measured at the mouth using diode laser absorption spectroscopy (at 2 mu m) and differential pressure sensing, respectively. NO is determined in a sidestream configuration using a quantum cascade laser based, cavity-enhanced absorption cell (at 5.2 mu m) which simultaneously measures sidestream CO2. The at-mouth and sidestream CO(2)measurements are used to enable the deconvolution of the sidestream NO measurement back to the at-mouth location. All measurements have a time resolution of 0.1 s, limited by the requirement of a reasonable limit of detection for the NO measurement, which on this timescale is 4.7 ppb (2 sigma). Using this methodology, NO expirograms (F(E)NOgrams) were measured and compared for eight healthy volunteers. The F(E)NOgrams appear to differ qualitatively between individuals and the hope is that the dynamic information encoded in these F(E)NOgrams will provide valuable additional insight into the location of the inflammation in the airways and potentially predict a response to therapy. A validation of the measurements at low-time resolution is provided by checking that results from previous studies that used a two-compartment model of NO production can be reproduced using our technology.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Real-Time Dense and Accurate Parallel Optical Flow using CUDA
    Marzat, Julien
    Dumortier, Yann
    Ducrot, Andre
    WSCG 2009, FULL PAPERS PROCEEDINGS, 2009, : 105 - +
  • [2] SENSORS AND REAL-TIME MEASUREMENTS - AN APPROACH TO PROGRAMMING OPTICAL SENSORS IN FOOD RESEARCH
    SWATLAND, HJ
    FOOD RESEARCH INTERNATIONAL, 1994, 27 (02) : 165 - 172
  • [3] Real-time multiaxial strain mapping using computer vision integrated optical sensors
    Hong, Sunguk
    Rachim, Vega Pradana
    Baek, Jin-Hyeok
    Park, Sung-Min
    NPJ FLEXIBLE ELECTRONICS, 2023, 7 (01)
  • [4] Real-time multiaxial strain mapping using computer vision integrated optical sensors
    Sunguk Hong
    Vega Pradana Rachim
    Jin-Hyeok Baek
    Sung-Min Park
    npj Flexible Electronics, 7
  • [5] A GENERAL APPROACH FOR REAL-TIME RAIL CONDITION MONITORING USING OPTICAL FIBER SENSORS
    Ilie, Gelu
    Stancalie, Andrei
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2016, 78 (04): : 295 - 306
  • [6] Real-time detection of bacterial contamination in dynamic aqueous environments using optical sensors
    Ji, J
    Schanzle, A
    Tabacco, MB
    ANALYTICAL CHEMISTRY, 2004, 76 (05) : 1411 - 1418
  • [7] Real-time process control of molecular beam epitaxy using in situ optical sensors
    Roth, J.A.
    Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest, 2000,
  • [8] Electrochemical and Optical Sensors for Real-Time Detection of Nitrate in Water
    Lal, Kartikay
    Jaywant, Swapna A.
    Arif, Khalid Mahmood
    SENSORS, 2023, 23 (16)
  • [9] Optical Sensors for Real-Time Measurement of Motorcycle Tilt Angle
    Norgia, Michele
    Boniolo, Ivo
    Tanelli, Mara
    Savaresi, Sergio M.
    Svelto, Cesare
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (05) : 1640 - 1649
  • [10] Robust and accurate real-time estimation of sensors signal parameters by a DSP approach
    Bertocco, M
    Flammini, A
    Marioli, D
    Taroni, A
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 697 - 702