Mass Flow Measurement of Two-phase Carbon Dioxide Using Coriolis Flowmeters

被引:0
|
作者
Wang, Lijuan [1 ,2 ]
Liu, Jinyu [2 ]
Yan, Yong [2 ]
Wang, Xue [3 ]
Wang, Tao [4 ]
机构
[1] North China Elect Power Univ, Sch Control & Comp Engn, Beijing 102206, Peoples R China
[2] Univ Kent, Sch Engn & Digital Arts, Canterbury CT2 7NT, Kent, England
[3] Univ Kent, Sch Math Stat & Actuarial Sci, Canterbury CT2 7NF, Kent, England
[4] KROHNE Ltd, 34-38 Rutherford Dr, Wellingborough NN8 6AE, England
基金
英国工程与自然科学研究理事会;
关键词
CCS; gas-liquid CO2 flow; flow measurement; Coriolis mass flowmeter; gas volume fraction; NEURAL-NETWORK; CAPTURE; STORAGE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Carbon Capture and Storage (CCS) is considered as an important technology to reduce CO2 emission from electrical power generation and other industrial processes. In the CCS chain, i.e. from capture to storage via transportation, it is essential to realize accurate measurement of CO2 flows for the purpose of accounting and potential leakage detection. However, there are some significant challenges for the current flow metering technologies to achieve the specified 1.5% measurement uncertainty in the EU-ETS (European Union - Emissions Trading Scheme) for all expected flow conditions. Moreover, there are very few CO2 flow test and calibration facilities that can recreate CCS conditions particularly two-phase CO2 flow in pipelines together with accurate measurement standards. As one of the most potential flowmeters that may be used in the CCS chain, Coriolis flowmeters have the advantages of direct measurement of mass flow rate regardless of its state (liquid, gas, gas/liquid two-phase or supercritical) in addition to the measurement of temperature and density of CO2 for the characterization of flow conditions. This paper assesses the performance of Coriolis flowmeters incorporating a soft-computing correction method for gas-liquid two-phase CO2 flow measurement. The correction method includes a pre-trained backpropagation neural network. Experimental work was conducted on a purpose-built 25 mm bore two-phase CO2 flow test rig for liquid mass flowrate between 300 kg/h and 3050 kg/h and gas mass flowrate from 0 to 330 kg/h under the fluid temperature of 19 similar to 21 degrees C and pressure of 54 similar to 58 bar. Experimental results suggest that the Coriolis flowmeters with the developed correction method are capable of providing the mass flow rate of gas-liquid CO2 flow with errors mostly within +/- 2% and +/- 1.5% on horizontal and vertical pipelines, respectively.
引用
收藏
页码:1299 / 1303
页数:5
相关论文
共 50 条
  • [31] Mass Flowrate Measurement of Slurry Using Coriolis Flowmeters and Data Driven Modeling
    Chowdhury, Wasif Shafaet
    Yan, Yong
    Coster-Chevalier, Marc-Antony
    Liu, Jinyu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 (1-12) : 1 - 12
  • [32] A Phase Difference Measurement Method Based on the Extended Kalman Filter for Coriolis Mass Flowmeters
    Chen, Nan
    Fan, Shangchun
    Zheng, Dezhi
    MEASUREMENT SCIENCE REVIEW, 2019, 19 (02): : 48 - 52
  • [33] Investigations into the behaviours of Coriolis flowmeters under air-water two-phase flow conditions on an optimized experimental platform
    Liu, Jinyu
    Wang, Tao
    Yan, Yong
    Wang, Xue
    Wang, Lijuan
    2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 1551 - 1556
  • [34] Coriolis Flowmeter for Two-Phase Flow Measurement Based on RS-Stacking Model
    Sun L.
    Zhao Z.
    Gao J.
    Zhang J.
    Shao X.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2023, 56 (11): : 1195 - 1204
  • [35] From disturbance to measurement: Application of Coriolis meter for two-phase flow with gas bubbles
    Zhu, Hao
    Rieder, Alfred
    Drahm, Wolfgang
    Lin, Yaoying
    Guettler, Andreas
    Wiesmann, Michael
    Hubensteiner, Josef
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 79
  • [36] The performance of electromagnetic flowmeters in a liquid metal two-phase flow
    Cha, JE
    Ahn, YC
    Se, KW
    Nam, HY
    Choi, JH
    Kim, MH
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2003, 40 (10) : 744 - 753
  • [37] Matrix Pencil Method for Coriolis Mass Flow Meter Signal Processing in Two-Phase Flow Conditions
    Ibryaeva, O.
    Salov, D.
    2017 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2017,
  • [39] Flow measurement of CO2 in a binary gaseous mixture using an averaging Pitot Tube and Coriolis mass flowmeters
    Adefila, K.
    Yan, Y.
    Sun, L.
    Wang, T.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 54 : 265 - 272
  • [40] Study on the gas-liquid two-phase flow two-phase flow characteristics of carbon dioxide removal by membrane method
    Li Yanchao
    Hao Zhiwu
    Zeng Xianping
    Li Fangqin
    Ren Jianxing
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 1797 - 1800