Diagnosis of stator winding insulation of large generator based on partial discharge measurement

被引:20
|
作者
Yuo, Bo [1 ]
Chen, Xiaolin [1 ]
Cheng, Yonghong [1 ]
Song, Jiancheng [1 ]
Xie, Hengkun [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
diagnosis; generator; partial discharge; stator bar insulation;
D O I
10.1109/TEC.2006.874223
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Stator winding insulation is aged by exposure to a combination of thermal, electrical, mechanical, and environmental stresses. Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of large generator. In the paper, two new parameters are proposed for the diagnosis of stator winding insulation based on the test results of multistress accelerating, aging test of stator bars. The test results show that the skewness of partial discharge phase resolved distribution and the high-frequency crest of partial discharge (PD) impulse change much more remarkably with the aging time than do the conventional parameters. Therefore, the two parameters could be considered as characteristic parameters for the diagnosis of stator winding insulation of the large generator. With these characteristic parameters, authors successfully assessed the insulation condition of actual stator bars removed from several large generators.
引用
收藏
页码:387 / 395
页数:9
相关论文
共 50 条
  • [31] Analysis of Insulation Diagnosis for Generator-Motor Stator Winding in Pumped Storage Power Plant
    Soo-Hoh Lee
    Tae-Sik Kong
    Hee-Dong Kim
    Journal of Electrical Engineering & Technology, 2020, 15 : 1269 - 1280
  • [32] Study on multi-stress aging test system for stator winding insulation of large generator
    Song, Jiancheng
    Yue, Bo
    Xie, Hengkun
    1600, Chinese Soc of Electrical Engineering, China (20): : 9 - 13
  • [33] Investigation of Partial Discharge Activity and Insulation Life of a Large Hydro Generator
    Soltani, Reza
    Gaillardetz, Pascalina
    Chichkin, Igor
    Ledger, Bruce
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 172 - 175
  • [34] Digital measurement of partial discharges in generator stator bar insulation during aging test
    Jiang, XW
    Wang, ZH
    Xie, HK
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 322 - 325
  • [35] Partial discharge - A valuable stator winding evaluation tool
    Maughan, Clyde V.
    Conference Record of the 2006 IEEE International Symposium on Electrical Insulation, 2006, : 388 - 391
  • [36] Problems with modern air-cooled generator stator winding insulation
    Griffith, G
    Tucker, S
    Milsom, J
    Stone, G
    IEEE ELECTRICAL INSULATION MAGAZINE, 2000, 16 (06) : 6 - 10
  • [37] New estimating techniques for multi-stress aging test of large generator stator winding insulation
    Song, JC
    Yue, B
    Xie, HK
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 951 - 956
  • [38] Partial Discharge Modeling of Internal Discharge in Electrical Machine Stator Winding
    Khan, Qasim
    Refaat, Shady S.
    Abu-Rub, Haitham
    Toliyat, Hamid A.
    2020 IEEE KANSAS POWER AND ENERGY CONFERENCE (KPEC), 2020,
  • [39] Diagnosis of stator insulation of generators and motors using in-service partial discharge testing
    Zhu, H
    Green, V
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 76 - 80
  • [40] Diagnosis of HV stator bars insulation in the presence of multi partial-discharge phenomena
    Contin, A
    Fenu, GF
    Parisini, T
    IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 488 - 491