Diagnosis of stator winding insulation of large generator based on partial discharge measurement

被引:20
|
作者
Yuo, Bo [1 ]
Chen, Xiaolin [1 ]
Cheng, Yonghong [1 ]
Song, Jiancheng [1 ]
Xie, Hengkun [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
diagnosis; generator; partial discharge; stator bar insulation;
D O I
10.1109/TEC.2006.874223
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Stator winding insulation is aged by exposure to a combination of thermal, electrical, mechanical, and environmental stresses. Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of large generator. In the paper, two new parameters are proposed for the diagnosis of stator winding insulation based on the test results of multistress accelerating, aging test of stator bars. The test results show that the skewness of partial discharge phase resolved distribution and the high-frequency crest of partial discharge (PD) impulse change much more remarkably with the aging time than do the conventional parameters. Therefore, the two parameters could be considered as characteristic parameters for the diagnosis of stator winding insulation of the large generator. With these characteristic parameters, authors successfully assessed the insulation condition of actual stator bars removed from several large generators.
引用
收藏
页码:387 / 395
页数:9
相关论文
共 50 条
  • [1] Aging diagnosis of large generator stator winding insulation based on digital discharge detection
    Song, JC
    Yue, B
    Xie, HK
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 765 - 769
  • [2] Diagnosis of stator winding insulation of large generator
    Xie, HK
    Bo, Y
    Hao, YP
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 274 - 277
  • [3] Condition Evaluation of Large Generator Stator Insulation Based on Partial Discharge Measurement
    Li, Ruihua
    Pan, Ling
    Yan, Chen
    Li, Hao
    Hu, Bo
    ADVANCES IN MECHANICAL ENGINEERING, 2013,
  • [4] Diagnosis of Generator Stator Winding Insulation Based on Dissipation Factor Measurement
    Liu, Fei
    Huang, Xingyi
    Jiang, Pingkai
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 120 - 123
  • [5] Analysis on aging condition of stator winding insulation of generator based on the moment characteristics of partial discharge
    Zhang, Xiao-Hong
    Zhang, Liang
    Yue, Bo
    Xie, Heng-Kun
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2002, 22 (05): : 94 - 98
  • [6] ASSESSMENT OF STATOR WINDING INSULATION CONDITION BASED ON ABSOLUTE PARTIAL DISCHARGE MAGNITUDE
    Sedding, H. G.
    Chan, C.
    Sasic, M.
    Stone, G. C.
    2023 INSUCON - 14TH INTERNATIONAL ELECTRICAL INSULATION CONFERENCE, 2023, : 19 - 23
  • [7] Analysis on the Ultrasonic Propagate for Partial Discharge in the Generator Stator Winding
    Yang, Yongming
    Jiang, Fan
    Zhang, Zulong
    Lin, Kunming
    ADVANCED MATERIALS AND COMPUTER SCIENCE, PTS 1-3, 2011, 474-476 : 1368 - 1372
  • [8] Assessment of the stator-winding insulation state based on partial-discharge measurements
    Obid, Matic
    Blazic, Bostjan
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2014, 81 (04): : 179 - 186
  • [9] Effect of manufacturer, winding age and insulation type on stator winding partial discharge levels
    Stone, GC
    Warren, V
    IEEE ELECTRICAL INSULATION MAGAZINE, 2004, 20 (05) : 13 - 17
  • [10] Study on test system of aging for stator winding insulation of large generator
    Zhang, X.H.
    Lu, W.S.
    Zhang, L.
    Le, B.
    Xie, H.K.
    Gaodianya Jishu/High Voltage Engineering, 2001, 27 (04):