Analysis of Gas Recirculation Influencing Factors of a Double Reheat 1000 MW Unit with the Reheat Steam Temperature under Control

被引:5
|
作者
Yue, Meng [1 ]
Ma, Guoqian [1 ]
Shi, Yuetao [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250100, Peoples R China
关键词
double reheating; temperature regulation; flue gas recycling; bypass flue; waste heat utilization; FIRED POWER-PLANT; EXERGY ANALYSIS; NOX REDUCTION; COMBUSTION; BOILER; OPTIMIZATION; EMISSION; SYSTEM; EFFICIENCY; DESIGN;
D O I
10.3390/en13164253
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, the simulation software EBSILON is used to simulate the reheat units, and the reheat temperature control mode is deeply explored. In the benchmark system, the influence of different load intermediate point temperature on the flue gas recirculation (FGR) is analyzed. Then, the effects of load, coal quality, excess air factor, and feed water temperature on FGR are studied under the premise of intermediate point temperature as design value, and the cause for FGR change is analyzed by comparing the cutoff bypass flue (CBF) system. The results show that under any load, the FGR decreases with the increase of the intermediate point temperature, while under low load, the change of the intermediate point temperature has a greater impact on the FGR rate. When the intermediate point temperature remains constant, the FGR plunge has an increase of load at low load and is almost unchanged at high load; the FGR rate of coal with low calorific value and high moisture content is low and the coal with low volatile and high ash content has great influence on reheat steam temperature; and the excess air factor and feed water temperature are inversely proportional to the flue gas recirculation rate. In the CBF system, the change trend is similar to the reference system, but under the same working condition, the FGR rate is higher than the latter.
引用
收藏
页数:21
相关论文
共 31 条
  • [21] Thermal-Hydraulic Calculation and Analysis on Evaporator System of a 1000 MW Ultra-Supercritical Pulverized Combustion Boiler with Double Reheat
    Wan, Li
    Yang, Dong
    Zhou, Xihong
    Dong, Le
    Li, Juan
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (03) : 807 - 816
  • [22] Thermal-Hydraulic Calculation and Analysis on Evaporator System of a 1000 MW Ultra-Supercritical Pulverized Combustion Boiler with Double Reheat
    Li Wan
    Dong Yang
    Xihong Zhou
    Le Dong
    Juan Li
    Journal of Thermal Science, 2021, 30 : 807 - 816
  • [23] Numerical Study on Effects of Flue Gas Recirculation on Combustion and Heat Transfer Characteristics in 660MW Double-reheat Tower-type Boiler
    Dong L.
    Yao Q.
    Jin X.
    Deng L.
    Che D.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (18): : 7150 - 7159
  • [24] Effect of FGR position on the characteristics of combustion, emission and flue gas temperature deviation in a 1000 MW tower-type double-reheat boiler with deep-air-staging
    Liu, Hu
    Zhang, Lei
    Li, Qianqian
    Zhu, Hua
    Deng, Lei
    Liu, Yinhe
    Che, Defu
    FUEL, 2019, 246 : 285 - 294
  • [25] COUPLED HIGH-LOW ENERGY LEVEL FLUE GAS HEAT RECOVERY SYSTEM AND ITS APPLICATION IN 1000MW ULTRA-SUPERCRITICAL DOUBLE REHEAT COAL-FIRED UNIT
    Liu, Jiayou
    Sun, Fengzhong
    Wei, Wei
    Ma, Lei
    PROCEEDINGS OF THE ASME POWER CONFERENCE JOINT WITH ICOPE-17, 2017, VOL 1, 2017,
  • [26] Tube-Wall Temperature Prediction of a 660-MW Ultra-Supercritical Double-Reheat Boiler under Flexible Peak Shaving
    XU Jiaye
    FAN Haojie
    WU Xiaojiang
    ZHANG Jian
    YE Nina
    ZHANG Qichao
    ZHANG Zhongxiao
    Journal of Thermal Science, 2024, 33 (06) : 2372 - 2385
  • [27] Tube-Wall Temperature Prediction of a 660-MW Ultra-Supercritical Double-Reheat Boiler under Flexible Peak Shaving
    Xu, Jiaye
    Fan, Haojie
    Wu, Xiaojiang
    Zhang, Jian
    Ye, Nina
    Zhang, Qichao
    Zhang, Zhongxiao
    JOURNAL OF THERMAL SCIENCE, 2024, 33 (06) : 2372 - 2385
  • [28] ENERGY CONSUMPTION DIFFERENCE ANALYSIS OF KEY PARAMETERS VARIATIONS OF 1000MW ULTRA-SUPERCRITICAL DOUBLE REHEAT COAL-FIRED POWER GENERATION SYSTEM
    Duan Liqiang
    Sun Jing
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2019, 2019,
  • [29] Research of Reheated Steam Temperature Multi-Model Predictive Control for 1000MW Ultra-Supercritical Unit
    Chen, Shihe
    Zhang, Xi
    Yan, Weiwu
    Wang, Guoliang
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1758 - +
  • [30] UNCERTAINTY ANALYSIS FOR SOURCE TERM EVALUATION OF HIGH TEMPERATURE GAS-COOLED REACTOR UNDER ACCIDENT CONDITIONS - IDENTIFICATION OF INFLUENCING FACTORS IN LOSS-OF-FORCED CIRCULATION ACCIDENTS
    Honda, Yuki
    Sato, Hiroyuki
    Nakagawa, Shigeaki
    Ohashi, Hirofumi
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 5, 2017,