Constant dose rate VMAT and step-and-shoot IMRT in head and neck cancer: a comparative plan analysis

被引:0
|
作者
Didona, A. [1 ]
Zucchetti, C. [2 ]
Dipilato, A. C. [2 ]
Iacco, M. [2 ]
Panizza, M. B. [3 ]
Frattegiani, A. [3 ]
Bini, V. [4 ]
Aristei, C. [3 ]
Tarducci, R. [2 ]
机构
[1] Osped Santa Maria Misericordia, SC Fis Sanit, Perugia, Italy
[2] Santa Maria Misericordia Hosp, Med Phys, Perugia, Italy
[3] Santa Maria Misericordia Hosp, Radiat Oncol, Perugia, Italy
[4] Perugia Univ, Internal Med, Perugia, Italy
关键词
D O I
10.1016/S0167-8140(16)32944-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-1693
引用
收藏
页码:S790 / S791
页数:2
相关论文
共 50 条
  • [31] Helical tomotherapy for head and neck squamous cell carcinoma: Dosimetric comparison with linear accelerator-based step-and-shoot IMRT
    Murthy, Vedang
    Master, Zubin
    Gupta, Tejpal
    Ghosh-Laskar, Sarbani
    Budrukkar, Ashwini
    Phurailatpam, Reenadevi
    Agarwal, Jaiprakash
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2010, 6 (02) : 194 - 198
  • [32] In vivo measurement of dose distribution in patients' lymphocytes: helical tomotherapy versus step-and-shoot IMRT in prostate cancer
    Zwicker, Felix
    Swartman, Benedict
    Roeder, Falk
    Sterzing, Florian
    Hauswald, Henrik
    Thieke, Christian
    Weber, Klaus-Josef
    Huber, Peter E.
    Schubert, Kai
    Debus, Juergen
    Herfarth, Klaus
    JOURNAL OF RADIATION RESEARCH, 2015, 56 (02) : 239 - 247
  • [33] A comparative planning study of step-and-shoot IMRT versus helical tomotherapy in a model patient
    Kim, Yong Nam
    Kim, Soo Kon
    Jeong, Kyoungkeun
    Lee, Chang Geol
    Keum, Ki Chang
    Lee, Ik Jae
    Cho, Jaeho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1481 - 1485
  • [34] A comparative planning study of step-and-shoot IMRT versus helical tomotherapy in a model patient
    Yong Nam Kim
    Soo Kon Kim
    Kyoungkeun Jeong
    Chang Geol Lee
    Ki Chang Keum
    Ik Jae Lee
    Jaeho Cho
    Journal of the Korean Physical Society, 2013, 63 : 1481 - 1485
  • [35] QA with alanine dosimetry for step and shoot IMRT of head and neck tumors
    De Ost, B
    Schaeken, B
    Wauters, T
    Van Gestel, D
    Coelmont, A
    Van den Weyngaert, D
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S114 - S114
  • [36] An algorithm to incorporate leaf transmission and head scatter corrections into step-and-shoot leaf sequences for IMRT
    Yang, Y
    Xing, L
    MEDICAL PHYSICS, 2002, 29 (06) : 1336 - 1336
  • [37] A Comparison of IMRT and VMAT Treatment Planning for Head and Neck Cancer With NTCP/TCP Analysis
    Kryger, M.
    Wang, W.
    Wu, S. P. P.
    Xue, J.
    Cheng, P.
    Das, I. J.
    Hu, K. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E680 - E680
  • [38] Measurements of Characteristics of Time Pattern in Dose Delivery in Step-and-Shoot IMRTCharakterisierung der zeitlichen Dosisverteilung in der Step-and-shoot-IMRT
    Mattias Schäfer
    Marc Münter
    Florian Sterzing
    Peter Häring
    Bernhard Rhein
    Jürgen Debus
    Strahlentherapie und Onkologie, 2005, 181 : 587 - 594
  • [39] Peripheral dose measurements in cervical cancer radiotherapy: a comparison of volumetric modulated arc therapy and step-and-shoot IMRT techniques
    Jia, Ming X.
    Zhang, Xu
    Yin, Ce
    Feng, Ge
    Li, Na
    Gao, Song
    Liu, Da W.
    RADIATION ONCOLOGY, 2014, 9
  • [40] Peripheral dose measurements in cervical cancer radiotherapy: a comparison of volumetric modulated arc therapy and step-and-shoot IMRT techniques
    Ming X Jia
    Xu Zhang
    Ce Yin
    Ge Feng
    Na Li
    Song Gao
    Da W Liu
    Radiation Oncology, 9