Subtractive non-contrast-enhanced MRI of lower limb veins using multiple flow-dependent preparation strategies

被引:2
|
作者
Li, Hao [1 ]
Priest, Andrew N. [2 ]
Patterson, Ilse [2 ]
Graves, Martin J. [2 ]
Lomas, David J. [1 ]
机构
[1] Univ Cambridge, Dept Radiol, St Andrews St, Cambridge CB2 3AP, England
[2] Addenbrookes Hosp, Dept Radiol, Cambridge, England
关键词
MR venography; non-contrast-enhanced; venous thrombosis; DEEP VENOUS THROMBOSIS; HIGH SIGNAL INTENSITY; DENTATE NUCLEUS; RESONANCE; VENOGRAPHY; ANGIOGRAPHY; PRECESSION; EVOLUTION; DIAGNOSIS;
D O I
10.1002/mrm.27530
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of acceleration-dependent vascular anatomy for non-contrast-enhanced MR venography (ADVANCE-MRV) in femoral veins and to investigate whether venous signal uniformity can be improved by applying multiple acquisitions with different flow suppressions or multiple flow suppressions in 1 acquisition. Methods: The ADVANCE-MRV method uses flow-sensitized modules to acquire a dark-artery image set and a dark-artery vein set, which are subsequently subtracted. Ten healthy volunteers were imaged using the ADVANCE-MRV sequence with improved venous suppression uniformity in the dark-artery vein images achieved by applying multiple flow suppressions in the same acquisition or by combining multiple images acquired with different flow suppressions. The performance of the improved technique was also evaluated in 13 patients with lower-limb deep venous thrombosis. Results: Multiple-preparation and multiple-acquisition approaches all improved venous signal uniformity and reduced the signal void artifacts observed in the original ADVANCE-MRV images. The multiple-acquisition approaches achieved excellent blood signal uniformity and intensity, albeit at the cost of an increase in the total acquisition time. The double-preparation approach demonstrated good performance in all measurements, providing a good compromise between signal uniformity and acquisition time. The blood signal spatial variation and its variation using different gradient amplitudes were reduced by 20% and 29%. All patient images showed uniform and bright venous signal in nonoccluded sections of vein. Conclusion: The enhanced ADVANCE-MRV methods substantially improved signal uniformity in healthy volunteers and patients with known deep venous thrombosis. The double-preparation approach gave good-quality femoral vein images, providing improved venous signal uniformity without increasing acquisition time in comparison to the original sequence.
引用
收藏
页码:1769 / 1783
页数:15
相关论文
共 32 条
  • [21] Clinical validity of non-contrast-enhanced VI-RADS: prospective study using 3-T MRI with high-gradient magnetic field
    Watanabe, Masanaka
    Taguchi, Satoru
    Machida, Haruhiko
    Tambo, Mitsuhiro
    Takeshita, Yuhei
    Kariyasu, Toshiya
    Fukushima, Keita
    Shimizu, Yuta
    Okegawa, Takatsugu
    Fukuhara, Hiroshi
    Yokoyama, Kenichi
    EUROPEAN RADIOLOGY, 2022, 32 (11) : 7513 - 7521
  • [22] SElf-gated Non-Contrast-Enhanced FUnctional Lung imaging (SENCEFUL) using a quasi-random fast low-angle shot (FLASH) sequence and proton MRI
    Fischer, Andre
    Weick, Stefan
    Ritter, Christian O.
    Beer, Meinrad
    Wirth, Clemens
    Hebestreit, Helge
    Jakob, Peter M.
    Hahn, Dietbert
    Bley, Thorsten
    Koestler, Herbert
    NMR IN BIOMEDICINE, 2014, 27 (08) : 907 - 917
  • [23] Comparison of axial and coronal acquisitions by non-contrast-enhanced renal 3D MR angiography using flow-in time-spatial labeling inversion pulse
    Junji Takahashi
    Yuki Ohmoto-Sekine
    Takashi Yoshida
    Mitsue Miyazaki
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 95 - 102
  • [24] Comparison of axial and coronal acquisitions by non-contrast-enhanced renal 3D MR angiography using flow-in time-spatial labeling inversion pulse
    Takahashi, Junji
    Ohmoto-Sekine, Yuki
    Yoshida, Takashi
    Miyazaki, Mitsue
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (01) : 95 - 102
  • [25] Pulmonary Imaging of Immunocompromised Patients during Hematopoietic Stem Cell Transplantation using Non-Contrast-Enhanced Three-Dimensional Ultrashort Echo Time (3D-UTE) MRI
    Metz, Corona
    Boeckle, David
    Heidenreich, Julius Frederik
    Weng, Andreas Max
    Benkert, Thomas
    Grigoleit, Gotz Ulrich
    Bley, Thorsten
    Koestler, Herbert
    Veldhoen, Simon
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2022, 194 (01): : 39 - 48
  • [26] Evaluation of static ulcer on lower extremities using wireless wearable near-infrared spectroscopy device: Effect of deep venous thrombosis on TRiggered Angiography Non-Contrast-Enhanced sequence magnetic resonance imaging
    Lin, Bor-Shyh
    Chen, Chien-Wei
    Zhou, Shao-Kui
    Tseng, Yuan-Hsi
    Wang, Shih-Chung
    Huang, Yao-Kuang
    PHLEBOLOGY, 2020, 35 (10) : 814 - 823
  • [27] Non-Contrast-Enhanced MR Angiography (NCE-MRA) of the Hand Using Flow-Sensitive Dephasing (FSD)-Prepared Steady-State Free Precession (SSFP) in Patients with Rheumatoid Arthritis
    Wang, Li
    He, Li Ping
    Zhi, Wei Hong
    Tang, Yu Kuan
    Zhang, Na
    Feng, Fei
    APPLIED MAGNETIC RESONANCE, 2016, 47 (08) : 835 - 845
  • [28] Non-Contrast-Enhanced MR Angiography (NCE-MRA) of the Hand Using Flow-Sensitive Dephasing (FSD)-Prepared Steady-State Free Precession (SSFP) in Patients with Rheumatoid Arthritis
    Li Wang
    Li Ping He
    Wei Hong Zhi
    Yu Kuan Tang
    Na Zhang
    Fei Feng
    Applied Magnetic Resonance, 2016, 47 : 835 - 845
  • [29] Free-breathing non-contrast-enhanced flow-independent MR angiography using magnetization-prepared 3D non-balanced dual-echo Dixon method: A feasibility study at 3 Tesla
    Yoneyama, Masami
    Zhang, Shuo
    Hu, Houchun Harry
    Chong, Le Roy
    Bardo, Dianna
    Miller, Jeffrey H.
    Toyonari, Nobuyuki
    Katahira, Kazuhiro
    Katsumata, Yasutomo
    Pokorney, Amber
    Ng, Chian Keat
    Kouwenhoven, Marc
    Van Cauteren, Marc
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 137 - 146
  • [30] Left Gastric Vein Visualization with Hepatopetal Flow Information in Healthy Subjects Using Non-Contrast-Enhanced Magnetic Resonance Angiography with Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulse
    Furuta, Akihiro
    Isoda, Hiroyoshi
    Ohno, Tsuyoshi
    Ono, Ayako
    Yamashita, Rikiya
    Arizono, Shigeki
    Kido, Aki
    Sakashita, Naotaka
    Togashi, Kaori
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 32 - 39