Energetic evaluations of an electrochemical hydrogen compressor

被引:10
|
作者
Pineda-Delgado, J. L. [1 ]
Menchaca-Rivera, J. A. [1 ]
Perez-Robles, J. F. [1 ]
Aviles-Arellano, L. M. [1 ]
Chavez-Ramirez, A. U. [2 ]
Gutierrez B, Cynthia K. [2 ]
de Jesus Hernandez-Cortes, Ramiro [3 ]
Rivera, J. G. [3 ]
Rivas, S. [4 ]
机构
[1] IPN, Ctr Invest & Estudios Avanzados, Campus Queretaro, Queretaro 76230, Mexico
[2] Ctr Invest & Desarrollo Tecnol Electroquim SC, Queretaro 76703, Mexico
[3] Univ Tecnol San Juan Rio, Div Ingn Quim & Energias Renovables, Queretaro 76800, Mexico
[4] Univ Autonoma Queretaro, Fac Ingn, Div Invest & Posgrad, Queretaro 76010, Mexico
关键词
Hydrogen; Electrochemical compressor; Efficiency; Potentiostatic; Galvanostatic; GAS-DIFFUSION LAYERS; ELECTROOSMOTIC TRANSPORT; FUEL-CELLS; WATER; PERFORMANCE; MEMBRANE; TECHNOLOGIES;
D O I
10.1016/j.est.2022.105675
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Hydrogen has been considered as the energy vector that could narrow the gap in the transition towards less polluting energy production. However, it faces compression and storage as technological challenges. Electrochemical hydrogen compression (EHC) is an interesting alternative since it demands low power consumption and could even separate hydrogen from a gas mixture. Therefore, it is necessary to conduct an energetic evaluation of the EHC related to its working conditions to establish the optimal ones in terms of efficiency. This work presents the evaluation and comparison of galvanostatic and potentiostatic operation modes of an EHC with a 50-bar pressure target. During the development of the experimental work, the values of the main overpotentials that affect an EHC were obtained: diffusion voltage, membrane voltage, activation overpotential, and contact overpotential. The highest actual work and power values were achieved at 0.215 V and 0.5 A/cm(2) (potentiostatic and galvanostatic mode), while the lowest were obtained at 0.072 V and 0.1 A/cm(2). This trend is reversed for voltage efficiency, reaching a maximum of 69.7 % for 0.072 V and a minimum of 19.9 % for 0.5 A/cm(2). The calculated flow efficiency values were, for all cases, higher than 94 %, with a maximum efficiency of 99 % at operating conditions of 0.5 A/cm(2) and 0.215 V. The global efficiencies of the EHC were also calculated, being more efficient when working in a potentiostatic mode, presenting values of 66 % at 0.072 V against 52 % at 0.1 A/cm(2).
引用
收藏
页数:12
相关论文
共 50 条
  • [41] COMPARISON OF THEORETICAL EVALUATIONS OF ENERGETIC ION RANGE DISTRIBUTIONS
    COWERN, NEB
    BIERSACK, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 205 (1-2): : 347 - 349
  • [42] Biodiesel as alternative fuel: Experimental analysis and energetic evaluations
    Carraretto, C
    Macor, A
    Mirandola, A
    Stoppato, A
    Tonon, S
    ENERGY, 2004, 29 (12-15) : 2195 - 2211
  • [43] A solid state electrochemical oxygen compressor
    Drevet, C
    Henault, M
    Feger, D
    Fouletier, J
    PROCEEDINGS OF THE FIRST INTERNATIONAL SYMPOSIUM ON CERAMIC MEMBRANES, 1997, 95 (24): : 309 - 314
  • [44] EXPERIMENTAL INVESTIGATION ON ELECTROCHEMICAL AMMONIA COMPRESSOR
    Tao, Ye
    Lee, Hoseong
    Hwang, Yunho
    Radermacher, Reinhard
    Wang, Chunsheng
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 122 - 129
  • [45] STEAM FLOW COMPRESSOR IN THE THERMAL AND ENERGETIC SYSTEM OF THE SUGAR FACTORY
    KRIVAN, Z
    LISTY CUKROVARNICKE A REPARSKE, 1990, 106 (05): : 103 - 110
  • [46] MODERN STATE OF HYDROGEN ENERGETIC
    Vinogradov, D. V.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2006, (01): : 153 - +
  • [47] Heliospheric energetic hydrogen atoms as a source of interplanetary energetic protons
    Hilchenbach, M
    Hsieh, KC
    Czechowski, A
    SOLAR WIND NINE, 1999, 471 : 779 - 782
  • [48] The Common Faults and Analysis of Hydrogen Compressor
    Han, Yanlu
    Wang, Jing
    Liu, Hai
    Zhang, Zhengguo
    2019 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2020, 440
  • [49] THERMAL ABSORPTION COMPRESSOR FOR A HYDROGEN REFRIGERATOR
    VANMAL, HH
    BERICHTE DER BUNSEN-GESELLSCHAFT FUR PHYSIKALISCHE CHEMIE, 1972, 76 (08): : 863 - &
  • [50] Electrochemical Evaluations of Glutamate at a Gold Electrode
    Sales, M. Goreti F.
    Martins, Claudia
    Barroso, M. Fatima
    Vaz, M. Carmo V. F.
    Oliveira, M. Beatriz P.
    Delerue-Matos, C.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2007, 25 (01) : 173 - 183