An interleaved sequence for simultaneous magnetic resonance angiography (MRA), susceptibility weighted imaging (SWI) and quantitative susceptibility mapping (QSM)

被引:25
|
作者
Chen, Yongsheng [1 ,2 ,3 ]
Liu, Saifeng [2 ]
Buch, Sagar [4 ]
Hu, Jiani [2 ,3 ]
Kang, Yan [1 ]
Haacke, E. Mark [1 ,2 ,3 ,4 ]
机构
[1] Northeastern Univ, Sinodutch Biomed & Informat Engn Sch, Shenyang, Liaoning, Peoples R China
[2] MRI Inst Biomed Res, Detroit, MI USA
[3] Wayne State Univ, Sch Med, Dept Radiol, Detroit, MI USA
[4] MRI Inst Biomed Res, Waterloo, ON, Canada
关键词
Magnetic resonance angiography and venography (MRAV); Magnetic resonance angiography (MRA); Susceptibility weighted imaging (SWI); Quantitative susceptibility mapping (QSM); TIME-OF-FLIGHT; PHASE-CONTRAST; VENOGRAPHY; ARTERIES; ACQUISITION; BRAIN; VEINS;
D O I
10.1016/j.mri.2017.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To image the entire vasculature of the brain with complete suppression of signal from background tissue using a single 3D excitation interleaved rephased/dephased multi-echo gradient echo sequence. This ensures no loss of signal from fast flow and provides co-registered susceptibility weighted images (SWI) and quantitative susceptibility maps (QSM) from the same scan. Materials and methods: The suppression of background tissue was accomplished by subtracting the flow-de phased images from the flow-rephased images with the same echo time of 12.5 ms to generate a magnetic resonance angiogram and venogram (MRAV). Further, a 2.5 ms flow-compensated echo was added in the re phased portion to provide sufficient signal for major arteries with fast flow. The QSM data from the rephased 12.5 ms echo was used to suppress veins on the MRAV to generate an artery-only MRA. The proposed approach was tested on five healthy volunteers at 3 T. Results: This three-echo interleaved GRE sequence provided complete background suppression of stationary tissues, while the short echo data gave high signal in the internal carotid and middle cerebral arteries (MCA). The contrast-to-noise ratio (CNR) of the arteries was significantly improved in the M3 territory of the MCA compared to the non-linear subtraction MRA and TOF-MRA. Veins were suppressed successfully utilizing the QSM data. Conclusion: The background tissue can be properly suppressed using the proposed interleaved MRAV sequence. One can obtain whole brain MRAV, MRA, SWI, true-SWI (or tSWI) and QSM data simultaneously from a single scan.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [31] Imaging of Reperfused Intramyocardial Hemorrhage with Cardiovascular Magnetic Resonance Susceptibility Weighted Imaging (SWI) (vol 10, e0123560, 2015)
    Goldfarb, J. W.
    Hasan, U.
    PLOS ONE, 2015, 10 (07):
  • [32] Magnetic Resonance Imaging Sialolithography: Direct Visualization of Calculi in the Submandibular Gland Using Susceptibility-Weighted Imaging (SWI) at 3 Tesla
    Fatemi-Ardekani, Ali
    Boylan, Colm
    Noseworthy, Michael D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (01) : 46 - 49
  • [33] Quantitative susceptibility mapping of multiple sclerosis lesions in a longitudinal cohort using magnetic resonance imaging
    Subramanian, K.
    Utriainen, D.
    Ramasamy, D. P.
    Beaver, J.
    Sethi, S.
    Schweser, F.
    Fawaz, M.
    Hagemeier, J.
    Rajagovindan, R.
    Zivadinov, R.
    Haacke, E. M.
    MULTIPLE SCLEROSIS JOURNAL, 2016, 22 : 213 - 214
  • [34] Susceptibility weighted magnetic resonance sequences "SWAN, SWI and VenoBOLD": Technical aspects and clinical applications
    Hodel, J.
    Rodallec, M.
    Gerber, S.
    Blanc, R.
    Maraval, A.
    Caron, S.
    Tyvaert, L.
    Zuber, M.
    Zins, M.
    JOURNAL OF NEURORADIOLOGY, 2012, 39 (02) : 71 - 86
  • [35] Influence of Susceptibility-weighted Imaging on Brain Magnetic Resonance Imaging Diagnostics
    Sanghan, N.
    Charoonratana, V
    Hirunpat, S.
    HONG KONG JOURNAL OF RADIOLOGY, 2019, 22 (01): : 32 - 38
  • [36] Susceptibility weighted magnetic resonance imaging of brain: A multifaceted powerful sequence that adds to understanding of acute stroke
    Naik, Deepti
    Viswamitra, Sanjaya
    Kumar, Ashok A.
    Srinath, M. G.
    ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2014, 17 (01) : 58 - 61
  • [37] Quantitative T2 Changes and Susceptibility-Weighted Magnetic Resonance Imaging in Murine Pregnancy
    Krishnamurthy, Uday
    Szalai, Gabor
    Neelayallia, Jaladhar
    Shen, Yimin
    Chaiworapongsa, Tinnakorn
    Hernandez-Andrade, Edgar
    Than, Nandor Gabor
    Xu, Zhonghui
    Yeo, Lami
    Haacke, Mark
    Romero, Roberto
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2014, 78 (01) : 33 - 40
  • [38] Magnetic resonance susceptibility weighted imaging in detecting intracranial calcification and hemorrhage
    ZHU WenzhenQI JianpinZHAN ChuanjiaSHU HonggeZHANG LinWANG Chengyuan XIA LimingHU Junwu and FENG Dingyi Department of RadiologyTongji HospitalTongji Medical CollegeHuazhong University of Science and TechnologyWuhan Hubei China
    中华医学杂志(英文版), 2008, (20) : 2021 - 2025
  • [39] Lobar pattern of microbleeds on susceptibility-weighted magnetic resonance imaging
    Shobha, N.
    Smith, Eric E.
    ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2010, 13 (03) : 223 - 224
  • [40] Magnetic resonance susceptibility weighted imaging in detecting intracranial calcification and hemorrhage
    Zhu Wen-Zhen
    Qi Jian-Pin
    Zhan Chuan-Jia
    Shu Hong-Ge
    Zhang Lin
    Wang Cheng-Yuan
    Xia Li-Ming
    Hu Jun-Wu
    Feng Ding-Yi
    CHINESE MEDICAL JOURNAL, 2008, 121 (20) : 2021 - 2025