Visual Servoing of a Medical Ultrasound Probe for Needle Insertion

被引:0
|
作者
Mathiassen, Kim [1 ,2 ]
Glette, Kyrre [1 ]
Elle, Ole Jakob [1 ,2 ]
机构
[1] Univ Oslo, Dept Informat, Gaustadalleen 23 B, N-0373 Oslo, Norway
[2] Oslo Univ Hosp, Intervent Ctr, Rikshospitalet, Postboks 4950 Nydalen, N-0424 Oslo, Norway
来源
2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA) | 2016年
关键词
PRINCIPLES; ROBOT;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Percutaneous needle insertion guided by ultrasound imaging is routinely performed in hospitals today. Automating these procedures could increase placement accuracy and lower time usage of health care personnel to perform these procedures. An important step in the automation is the estimation of the needle orientation and position in the ultrasound image. One approach to estimate the needle orientation and position is to have the needle aligned with the image plane of the ultrasound probe. Aligning the needle with the plane is difficult, even with accurate measurements and calibration of both needle and probe. In this paper we propose a visual servoing method to move the ultrasound probe, using a robot to align the image plane of the probe with the needle. The method segments the needle and updates a set of visual features based on a model of the needle. A state machine is used to keep track of the alignment process, and different visual features are used to control the probe in the different states. Both simulation using simple synthetic images and experiments in a water tank are conducted to validate the proposed method. The simulation shows that the proposed method manages to align the probe plane with the needle. The alignment process is slower in the actual robot experiment, but still aligns the probe plane with the needle. The method is shown to work under simplified conditions, and is a step towards a method that could be applied in a clinical setting.
引用
收藏
页码:3426 / 3433
页数:8
相关论文
共 50 条
  • [41] The effect of visual and haptic feedback on manual and teleoperated needle insertion
    Gerovichev, O
    Marayong, P
    Okamura, AM
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION-MICCAI 2002, PT 1, 2002, 2488 : 147 - 154
  • [42] A multi-plane approach for ultrasound visual servoing: application to a registration task
    Nadeau, Caroline
    Krupa, Alexandre
    IEEE/RSJ 2010 INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2010), 2010, : 5706 - 5711
  • [43] Full motion tracking in ultrasound using image speckle information and visual servoing
    Krupa, Alexandre
    Fichtinger, Gabor
    Hager, Gregory D.
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-10, 2007, : 2458 - +
  • [44] Maintaining visibility constraints during tele-echography with ultrasound visual servoing
    Li, Tao
    Kermorgant, Olivier
    Krupa, Alexandre
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 4856 - 4861
  • [45] Robust ultrasound-based visual servoing for beating heart intracardiac surgery
    Vitrani, Marie-Aude
    Mitterhofer, Hubert
    Morel, Guillaume
    Bonnet, Nicolas
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-10, 2007, : 3021 - +
  • [46] A framework for visual servoing
    Kragic, D
    Christensen, HI
    COMPUTER VISION SYSTEMS, PROCEEDINGS, 2003, 2626 : 345 - 354
  • [47] Geometric visual servoing
    Cowan, NJ
    Chang, DE
    IEEE TRANSACTIONS ON ROBOTICS, 2005, 21 (06) : 1128 - 1138
  • [48] Photometric Visual Servoing
    Collewet, Christophe
    Marchand, Eric
    IEEE TRANSACTIONS ON ROBOTICS, 2011, 27 (04) : 828 - 834
  • [49] Visual Servoing in Robotics
    Pomares, Jorge
    ELECTRONICS, 2019, 8 (11)
  • [50] Robust visual servoing
    Kragic, D
    Christensen, HI
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2003, 22 (10-11): : 923 - 939