共 50 条
Comparison between anaerobic-anoxic-oxic and anoxic-oxic systems for coke plant wastewater treatment
被引:41
|作者:
Zhang, M
[1
]
Tay, JH
[1
]
Qian, Y
[1
]
Gu, XS
[1
]
机构:
[1] TSING HUA UNIV,DEPT ENVIRONM ENGN,BEIJING 100084,PEOPLES R CHINA
来源:
关键词:
D O I:
10.1061/(ASCE)0733-9372(1997)123:9(876)
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
Coke plant wastewater produces severe pollution throughout china because coal is the main energy resource. The anoxic-oxic (A(2)-O) system can be used to treat this type of wastewater for simultaneous removal of NH3-N and GOD. A comparative study between an anaerobic-anoxic-oxic (A(1)-A(2)-O) system and an A(2)-O system for coke plant wastewater treatment under the same operational conditions was undertaken to examine removal efficiencies of COD and NH3-N, denitrification performance, and transformation of organic pollutants in each system. The experimental results showed that the A(1)-A(2)-O system was comparatively more effective not only in nitrification but also in denitrification performance, The total NH3-N removal efficiency and the anoxic NOx-N removal rate of the A(1)-A(2)-O system were about 20% higher and more than twice that of the A(2)-O system, respectively. Coke plant wastewater subjected to anaerobic treatment resulted in less inhibitory effect on the subsequent nitrification process, and provided a more biodegradable and suitable carbon substrate far denitrifying bacteria. The anaerobic stage played an important role in nitrogen reduction in coke plant wastewater treatment.
引用
收藏
页码:876 / 883
页数:8
相关论文