Evaluation of volatile eluents and electrolytes for high-performance liquid chromatography-electrospray ionization mass spectrometry and capillary electrophoresis-electrospray ionization mass spectrometry of proteins - II. Capillary electrophoresis

被引:64
|
作者
Huber, CG [1 ]
Premstaller, A [1 ]
Kleindienst, G [1 ]
机构
[1] Leopold Franzens Univ, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
基金
奥地利科学基金会;
关键词
buffer composition; capillary electrophoresis-mass spectrometry; electrospray ionization; polystyrene coating; coating; capillary columns; peptides; proteins;
D O I
10.1016/S0021-9673(99)00533-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peptides and proteins were separated by capillary electrophoresis (CE) in fused-silica capillaries coated with an irreversibly adsorbed monolayer of derivatized polystyrene nanoparticles. Whereas phosphate buffer, pH 3.10, enabled the highly efficient separation of basic proteins with plate counts up to 1 400 000 m(-1), volatile buffer components such as formic acid or acetic acid titrated with ammonia to the desired pH had to be used for the direct coupling of CE with electrospray ionization mass spectrometry (ESI-MS). Compared to 40 mM phosphoric acid-sodium hydroxide, pH 3.10, a background electrolyte containing 125 mM formic acid-ammonia, pH 4.00, was shown to yield equivalent separation efficiency. Investigation of the influence of buffered electrolytes on the ESI-MS signal of lysozyme at pH 2.70-4.00 showed that the charge state distribution shifted to lower charge states at higher pH with a concomitant five-fold decrease in signal intensity of the most abundant signal. The presence of trifluoroacetic acid in the background electrolyte greatly increased the level of baseline noise and completely inhibited the observation of any mass signals related to proteins. Full scan spectra could be acquired from 50-500 fmol amounts of proteins during coupled CE-ESI-NIS utilizing 100-125 mM formic acid-ammonia, pH 3.10. However, compared to UV detection, considerable band broadening is observed with ESI-MS detection which is mainly attributed to column overloading, band spreading in the interface, and scanning data acquisition. Finally, the major whey proteins beta-lactoglobulin A, beta-lactoglobulin B, and alpha-lactalbumin were identified in a whey drink by comparison of molecular masses determined by CE-ESI-MS to molecular masses calculated from the amino acid sequence. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 189
页数:15
相关论文
共 50 条
  • [41] DETERMINATION OF AMINO-ACIDS BY ONLINE CAPILLARY ELECTROPHORESIS-ELECTROSPRAY IONIZATION MASS-SPECTROMETRY
    LU, W
    YANG, G
    COLE, RB
    ELECTROPHORESIS, 1995, 16 (04) : 487 - 492
  • [42] Capillary electrophoresis-electrospray ionization-mass spectrometry interfaces: Fundamental concepts and technical developments
    Bonvin, Gregoire
    Schappler, Julie
    Rudaz, Serge
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 : 17 - 31
  • [43] Characterization of the methanolic extract of hops using capillary electrophoresis-electrospray ionization-mass spectrometry
    Arraez-Roman, David
    Cortacero-Ramirez, Sonia
    Segura-Carretero, Antonio
    Martin-Lagos Contreras, Jose-Antonio
    Fernandez-Gutierrez, Alberto
    ELECTROPHORESIS, 2006, 27 (11) : 2197 - 2207
  • [44] High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies
    Premstaller, A
    Oberacher, H
    Walcher, W
    Timperio, AM
    Zolla, L
    Chervet, JP
    Cavusoglu, N
    van Dorsselaer, A
    Huber, CG
    ANALYTICAL CHEMISTRY, 2001, 73 (11) : 2390 - +
  • [45] Microchip capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins using uncoated Ormocomp microchips
    Sikanen, Tiina
    Aura, Susanna
    Franssila, Sami
    Kotiaho, Tapio
    Kostiainen, Risto
    ANALYTICA CHIMICA ACTA, 2012, 711 : 69 - 76
  • [46] Analysis of alkaloids in Coptis chinensis Franch by high performance capillary electrophoresis-electrospray ionization time of flight mass Spectrometry
    Chen Jun-Hui
    Zhao Heng-Qiang
    Li Wen-Hong
    Wang Xiao-Ru
    Lee, Frank Sen-Chun
    Yang Huang-Hao
    ACTA CHIMICA SINICA, 2007, 65 (23) : 2743 - 2749
  • [47] In-spray supercharging of intact proteins by capillary electrophoresis-electrospray ionization-mass spectrometry using sheath liquid interface
    Bonvin, Gregoire
    Rudaz, Serge
    Schappler, Julie
    ANALYTICA CHIMICA ACTA, 2014, 813 : 97 - 105
  • [48] Capillary electrophoresis and off-line capillary electrophoresis-electrospray ionization quadrupole time-of-flight tandem mass spectrometry of carbohydrates
    Zamfir, A
    König, S
    Althoff, J
    Peter-Katalinc, J
    JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) : 291 - 299
  • [49] Comparing and Combining Capillary Electrophoresis Electrospray Ionization Mass Spectrometry and Nano-Liquid Chromatography Electrospray Ionization Mass Spectrometry for the Characterization of Post-translationally Modified Histones
    Sarg, Bettina
    Faserl, Klaus
    Kremser, Leopold
    Halfinger, Bernhard
    Sebastiano, Roberto
    Lindner, Herbert H.
    MOLECULAR & CELLULAR PROTEOMICS, 2013, 12 (09) : 2640 - 2656
  • [50] Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
    Qiu, Danye
    Eisenbeis, Verena B.
    Saiardi, Adolfo
    Jessen, Henning J.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (174):