Agreement Between Standard Optical Coherence Tomography and Optical Coherence Tomography-Based Angiography in Estimating Retinal Nerve Fiber Layer Thickness

被引:1
|
作者
Yilmaz, Hayati [1 ]
Koylu, Mehmet Talay [2 ]
Yilmaz, Alper Can [2 ]
Durukan, Ali Hakan [2 ]
Uysal, Yusuf [2 ]
机构
[1] Univ Hlth Sci Turkey, Umraniye Training & Res Hosp, Clin Ophthalmol, Istanbul, Turkey
[2] Univ Hlth Sci Turkey, Gulhane Med Fac, Dept Ophthalmol, Ankara, Turkey
关键词
Glaucoma; optical; coherence; angiography; agreement; SPECTRAL-DOMAIN; VESSEL DENSITY; STRATUS OCT; TIME-DOMAIN; NORMAL EYES; GLAUCOMA; HEALTHY; REPEATABILITY; DAMAGE; ABILITY;
D O I
10.4274/tjo.galenos.2020.18488
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To investigate the agreement between optical coherence tomography (OCT) and OCT-based angiography in estimating retinal nerve fiber layer thickness (RNFLT) and evaluate the associations between peripapillary vessel density (VD) and RNFLT measurements obtained with both devices. Materials and Methods: The AngioVue (Optovue Inc., Fremont, CA, USA) and Spectralis (Heidelberg Engineering, Heidelberg, Germany) images of 325 patients were screened retrospectively. RNFLT values were recorded using both devices. The intraclass correlation coefficient (ICC) and Bland-Altman plots were obtained to investigate the agreement between the devices. Age- and intraocular pressurecorrected associations between VD and RNFLT measured by the two devices were analyzed using linear regression models. Results: ICC revealed excellent agreement for global, superior, inferior, and temporal RNFLT and good agreement for the nasal quadrant (ICC=0.895, 0.936, 0.923, 0.887, and 0.614, respectively). The Bland-Altman plots showed poor agreement for all measurements with a large span of limits of agreement and significant proportional bias (p<0.05). VD was found to be strongly associated with the RNFLT measurements of both devices (p<0.001). Conclusion: The disagreement between the devices should be considered in clinical practice, and the data should not be used interchangeably. The association of the peripapillary VD with RNFLT using both devices indicated that RNFLT assessed by the AngioVue could be used in glaucoma management along with VD.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 50 条
  • [21] Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography
    Kanamori, A
    Nakamura, M
    Escano, MFT
    Seya, R
    Maeda, H
    Negi, A
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) : 513 - 520
  • [22] Evaluation of heredity as a determinant of retinal nerve fiber layer thickness as measured by optical coherence tomography
    Hougaard, JL
    Kessel, L
    Sander, B
    Kyvik, KO
    Sorensen, TIA
    Larsen, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (07) : 3011 - 3016
  • [23] Analysis of the retinal nerve fiber layer texture related to the thickness measured by optical coherence tomography
    Odstrcilik, J.
    Kolar, R.
    Tornow, R. P.
    Budai, A.
    Jan, J.
    Mackova, P.
    Vodakova, M.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 105 - 110
  • [24] Sources of errors in measurement of retinal nerve fiber layer thickness using optical coherence tomography
    Mansoori, Tarannum
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (02) : 674 - 674
  • [25] Study of retinal nerve fiber layer thickness in diabetic patients using optical coherence tomography
    Bhaskaran, Aparna
    Babu, Mahesh
    Sudhakar, N. A.
    Kudlu, Krishna Prasad
    Shashidhara, B. C.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (03) : 920 - 926
  • [26] Evaluation of myopia on retinal nerve fiber layer thickness measured by Spectralis optical coherence tomography
    Zha, Yi
    Zhuang, Jinfei
    Lin, Da
    Feng, Wangqiang
    Zheng, Haihua
    Cai, Jianqiu
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (03) : 2716 - 2720
  • [27] Macular and retinal nerve fiber layer thickness in Japanese measured by Stratus optical coherence tomography
    Oshitari, Toshiyuki
    Hanawa, Katsuhiro
    Adachi-Usami, Emiko
    CLINICAL OPHTHALMOLOGY, 2007, 1 (02): : 133 - 140
  • [28] A Myopic Normative Database for Retinal Nerve Fiber Layer Thickness Using Optical Coherence Tomography
    Yilmaz, Hayati
    Yesiltas, Yagmur Seda
    Aydemir, Emre
    Aydemir, Gozde Aksoy
    Ozisik, Gulce Gokgoz
    Koylu, Mehmet Talay
    Cagatay, Caglar
    Bayer, Atilla
    JOURNAL OF GLAUCOMA, 2022, 31 (10) : 816 - 825
  • [29] Evaluation of the retinal nerve fiber layer and choroidal thickness with optical coherence tomography in patients with psoriasis
    Yusufoglu, Elif
    Gurok, Nese
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 44
  • [30] Retinal nerve fiber layer thickness and radial peripapillary capillaries density in myopic adults with optical coherence tomography angiography
    Ma, Chunhui
    Chen, Chunwen
    Zhang, Yutong
    Yao, Jingyan
    BMC OPHTHALMOLOGY, 2024, 24 (01)