FIRE RESISTANCE TESTS ON CONCRETE COLUMNS

被引:0
|
作者
dos Santos, Cristina C. [1 ]
Rodrigues, Joao Paulo C. [2 ]
Pires, Tiago [3 ]
机构
[1] Polytech Inst Castelo Branco, Castelo Branco, Portugal
[2] Univ Coimbra, Coimbra, Portugal
[3] Univ Fed Pernambuco, Porto, Portugal
关键词
column; reinforced concrete; fire resistance; restraining; spalling;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The reinforced concrete elements are known to have enhanced fire behaviour however there are many things that can affect that performance. In the last years there have been carried out, in the University of Coimbra, Portugal, dozens of fire resistance tests on concrete columns where it was tested the influence of various parameters on the behaviour of these columns. Several parameters that might have influence on the behaviour of concrete columns in fire, were tested: cross section shape (round and square), longitudinal reinforcement ratio, slenderness of the column, stiffness of the surrounding structure (restraint level), load level and the load eccentricity. The restraining level to the thermal elongation of the columns showed not being a relevant parameter in their fire resistance probably due the increase in rotational restrain associated with the increase in the axial restraint. The first increases the fire resistance while the second reduces. The increasing of the load level lead to a reduction, while the increasing of the longitudinal reinforcement ratio or the decreasing of the slenderness of the columns lead to an increasing of the fire resistance. The spalling was also an aspect analysed in these tests. The higher load levels, the shape of the cross-section, the type of concrete with or without steel and / or polypropylene fibres, and the steel reinforcement ration was parameters that showed to have influence on concrete cracking and spalling.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Pipe-concrete columns of buildings and their fire-resistance determination
    Ilyin, Nikolay
    Kondratyeva, Nadezhda
    Zaiko, Vasily
    XXVII R-S-P SEMINAR, THEORETICAL FOUNDATION OF CIVIL ENGINEERING (27RSP) (TFOCE 2018), 2018, 196
  • [32] Fire resistance design method of axially loaded reinforced concrete columns
    Zhang, Zhi-Mei
    Ye, Zhi-Ming
    Liu, Tao
    Gongcheng Lixue/Engineering Mechanics, 2008, 25 (04): : 171 - 176
  • [33] Fire resistance of reinforced concrete columns with elastically restrained thermal elongation
    Martins, Alberto M. B.
    Rodrigues, Joao Paulo C.
    ENGINEERING STRUCTURES, 2010, 32 (10) : 3330 - 3337
  • [34] Experimental study on fire resistance of precast concrete columns with efficient reinforcement
    Xu, Haoming
    Yu, Min
    Xue, Congcong
    Xu, Lihua
    Ye, Jianqiao
    ENGINEERING STRUCTURES, 2020, 204
  • [35] Fire resistance of reinforced concrete columns: State of the art, analysis and prediction
    Wang, Yuzhuo
    Liu, Zejian
    Zhang, Xiao
    Qu, Shuang
    Xu, Tiangui
    JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [36] Research on fire resistance of recycled concrete filled steel tubular columns
    Luo, Chaoning
    Zha, Xiaoxiong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 35 - 41
  • [37] Fire resistance design of externally protected concrete filled tubular columns
    Wang, Y. C.
    Orton, A. H.
    TUBULAR STRUCTURES XII, 2009, : 625 - +
  • [38] Fire Resistance of Bar-reinforced Concrete Filled Steel Columns
    Xu, Lei
    Liu, Y. B.
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 757 - 762
  • [39] Analysis on fire resistance of concrete-filled steel tube columns
    Yang, Hua
    Han, Lin-Hai
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2003, 35 (SUPPL.): : 93 - 96
  • [40] Fire resistance of axially loaded concrete filled steel tube columns
    Yin, Jing
    Zha, Xiao-xiong
    Li, Long-yuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (07) : 723 - 729