Theoretical studies of a hybrid ejector CO2 compression cooling system for vehicles and preliminary experimental investigations of an ejector cycle

被引:36
|
作者
Chen, Xiangjie [1 ]
Worall, Mark [1 ]
Omer, Siddig [1 ]
Su, Yuehong [1 ]
Riffat, Saffa [1 ]
机构
[1] Univ Nottingham, Inst Architecture & Built Environm, Nottingham NG7 2RD, England
基金
英国工程与自然科学研究理事会;
关键词
Hybrid ejector system; Exhaust gas; Simulation; Experimental investigation; Ejector cycle; HEAT;
D O I
10.1016/j.apenergy.2012.09.032
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents theoretical investigations into a hybrid ejector and CO2 vapour compression (VC) system for road transport cooling. The purpose is to utilise the waste heat from exhaust gas and the VC subsystem to drive the ejector system, whose cooling effect will be employed to subcool the VC sub-system. Exploitation of the energy consumption ratio between ejector sub-system and CO2 VC sub-system indicated that the more energy obtained from exhausted gas, the better system performance could be achieved for CO2 VC sub-system, and hence higher cooling capacity of the VC sub-system at the same compression power. Thermodynamic simulations of two sub-systems and the hybrid system were presented. The results indicated that, at boiler temperature of 120 degrees C, evaporator temperature of 10 degrees C, a COP of 0.584 was achieved for hybrid system, with 22% improvement over a single ejector cycle. Preliminary experimental studies were carried out on a single ejector cycle, with boiler temperatures between 115 degrees C and 130 degrees C, and evaporator temperatures between 5 degrees C and 10 degrees C. The effects of various operation conditions on the overall ejector operation were coherently analysed. The COP of the ejector sub-system from experimental results was approximately 85% compared with simulation results, which showed a good agreement between theoretical analysis and experimental results. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:931 / 942
页数:12
相关论文
共 50 条
  • [31] Thermodynamic performance evaluation of an ejector-enhanced transcritical CO2 parallel compression refrigeration cycle
    Bai, Tao
    Shi, Rongxuan
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 149 : 49 - 61
  • [32] Critical comparison between single-phase ejector and two-phase ejector in simulated CO2 transcritical commercial cooling system
    Paez, Ana
    Haberschill, Philippe
    Revellin, Remi
    Michel, Benoit
    Tobaly, Pascal
    Ballot-Miguet, Benedicte
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 718 - 732
  • [33] Experimental study of a two-phase ejector for CO2 transcritical refrigeration system
    Haberschill, Philippe
    Nehdi, Ezzeddine
    Kairouani, Lakdar
    Elakhdar, Mouna Abouda
    ARCHIVES OF THERMODYNAMICS, 2021, 42 (04) : 217 - 246
  • [34] Performance analysis of a double-efficient CO2 cooling and heating system using an ejector
    Wang, Zihang
    Fan, Mingjing
    He, Guogeng
    Song, Hai
    Yang, Wei
    APPLIED THERMAL ENGINEERING, 2023, 227
  • [35] Performance characteristics of ejector expander transcritical CO2 refrigeration cycle
    Ersoy, H. Kursad
    Bilir, Nagihan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2012, 226 (A5) : 623 - 635
  • [36] TRANSCRITICAL CO2 HEAT PUMP WITH EXPANDER-EJECTOR CYCLE
    Sit, B.
    Timcenco, D.
    Sit, M.
    PROBLEMELE ENERGETICII REGIONALE, 2010, (01): : 75 - 80
  • [37] Thermodynamic design and simulation of a CO2 based transcritical vapour compression refrigeration system with an ejector
    Ahammed, Md. Ezaz
    Bhattacharyya, Souvik
    Ramgopal, M.
    International Journal of Refrigeration, 2014, 45 : 177 - 188
  • [39] Experimental study on the improvement of CO2 air conditioning system performance using an ejector
    Lee, Jae Seung
    Kim, Mo Se
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1614 - 1625