Fiber Orientation Effects in Fused Filament Fabrication of Air-Cooled Heat Exchangers

被引:25
|
作者
Mulholland, T. [1 ]
Goris, S. [1 ]
Boxleitner, J. [1 ]
Osswald, T. A. [1 ]
Rudolph, N. [1 ]
机构
[1] Univ Wisconsin, Dept Mech Engn, Madison, WI 53706 USA
基金
美国能源部;
关键词
D O I
10.1007/s11837-017-2733-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Fused filament fabrication (FFF) is a type of additive manufacturing based on material extrusion that has long been considered a prototyping technology. However, the right application of material, process, and product can be used for manufacturing of end-use products, such as air-cooled heat exchangers made by adding fillers to the base polymer, enhancing the thermal conductivity. Fiber fillers lead to anisotropic thermal conductivity, which is governed by the process-induced fiber orientation. This article presents an experimental study on the microstructure-property relationship for carbon fiber-filled polyamide used in FFF. The fiber orientation is measured by micro-computed tomography, and the thermal conductivity of manufactured samples is measured. Although the thermal conductivity is raised by more than three times in the fiber orientation direction at a load of only 12 vol.%, the enhancement is low in the other directions, and this anisotropy, along with certain manufacturing restrictions, influences the final part performance.
引用
收藏
页码:298 / 302
页数:5
相关论文
共 50 条
  • [41] AIR-COOLED EXCHANGERS IN COLD CLIMATES
    SHIPES, KV
    CHEMICAL ENGINEERING PROGRESS, 1974, 70 (07) : 53 - 58
  • [42] Shape optimisation of air-cooled finned-tube heat exchangers
    Nemati, H.
    Moghimi, M. A.
    Sapin, P.
    Markides, C. N.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 150
  • [43] The influence of wind on the performance of forced draught air-cooled heat exchangers
    Duvenhage, K
    Kroger, DG
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 62 (2-3) : 259 - 277
  • [44] USE OF INDUSTRIAL EXPERIENCES IN CONSTRUCTING AIR-COOLED HEAT-EXCHANGERS
    BARATOSSY, J
    GANOCZY, J
    CHEMISCHE TECHNIK, 1976, 28 (06): : 380 - 380
  • [45] Constructal design of finned tubes used in air-cooled heat exchangers
    Hossein Shokouhmand
    Shoeib Mahjoub
    Mohammad Reza Salimpour
    Journal of Mechanical Science and Technology, 2014, 28 : 2385 - 2391
  • [46] SIMULATION OF AIR-COOLED HEAT-EXCHANGERS IN THE CHEMICAL-INDUSTRY
    WUNDERLICH, D
    CHEMISCHE TECHNIK, 1981, 33 (09): : 496 - 496
  • [47] OPERATION OF AIR-COOLED HEAT-EXCHANGERS IN CHEMICAL-INDUSTRY
    KUNZE, R
    NOACK, J
    STUBNER, F
    CHEMISCHE TECHNIK, 1976, 28 (11): : 659 - 661
  • [48] Constructal design of finned tubes used in air-cooled heat exchangers
    Shokouhmand, Hossein
    Mahjoub, Shoeib
    Salimpour, Mohammad Reza
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (06) : 2385 - 2391
  • [49] HOW TO PROTECT AIR-COOLED HEAT-EXCHANGERS AGAINST OVERPRESSURE
    BROWN, PMM
    FRANCE, DW
    HYDROCARBON PROCESSING, 1975, 54 (08): : 103 - 106
  • [50] Plume recirculation in mechanical-draft air-cooled heat exchangers
    Duvenhage, K
    Kroger, DG
    HEAT TRANSFER ENGINEERING, 1995, 16 (04) : 42 - 49