Analysis of operator human errors in hydrogen refuelling stations: Comparison between human rate assessment techniques

被引:60
|
作者
Castiglia, F. [1 ]
Giardina, M. [1 ]
机构
[1] Univ Palermo, Nucl Sect, Dept Energy, I-90128 Palermo, Italy
关键词
Hydrogen refuelling station; Storage unit; Risk analysis; Human errors; Fuzzy HEART; CREAM; RELIABILITY QUANTIFICATION TECHNIQUES; RISK ANALYSIS; VALIDATION; SAFETY; HEART; THERP; JHEDI; METHODOLOGY;
D O I
10.1016/j.ijhydene.2012.10.092
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The use of hydrogen as an energy carrier for road transport appears to be an optimal solution for the reduction of greenhouse gas emissions. Nevertheless, the development of this technology depends on the growth and diffusion of production, storage and refuelling infrastructures together with accurate risk analyses to appropriately design the safety and management systems used in these plants. Moreover, to improve safety standards, it is also important to focus attention on the estimation of hazards related to human factors, as this is one of the major causes leading to accidental events, especially in complex industrial technology. The paper reports a case study relevant to operator errors that occur during maintenance procedures on safety venting devices in refuelling station hydrogen storage systems performed using first- and second-generation Human Rate Assessment (HRA) techniques. HEART (Human Error Assessment and Reduction Technique) methodology, a first-generation HRA method, which was modified on the basis of the fuzzy set concept, was employed to evaluate the probability of erroneous actions. The obtained results have been compared with results obtained using CREAM (second-generation) methodology. The critical analyses of the obtained results have also allowed to provide procedural recommendations and suggestions regarding safety equipment and procedures which can be adopted to reduce the risk of accidents. Copyright (c) 2012, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1166 / 1176
页数:11
相关论文
共 50 条
  • [41] A MORPHOMETRICAL COMPARISON OF RIGHT AND LEFT WHOLE HUMAN VASTUS LATERALIS MUSCLE - HOW TO REDUCE SAMPLING ERRORS IN BIOPSY TECHNIQUES
    LEXELL, J
    TAYLOR, CC
    CLINICAL PHYSIOLOGY, 1991, 11 (03): : 271 - 276
  • [42] A proteomic analysis on human sperm tail: comparison between normozoospermia and asthenozoospermia
    Hashemitabar, Mahmoud
    Sabbagh, Susan
    Orazizadeh, Mahmoud
    Ghadiri, Atta
    Bahmanzadeh, Maryam
    JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 2015, 32 (06) : 853 - 863
  • [43] COMPARISON BETWEEN PIXE AND FLAME SPECTROSCOPY FOR TRACE ANALYSIS IN HUMAN ALBUMINS
    DECONNINCK, G
    BODART, F
    DEMOULIN, E
    NUCLEAR INSTRUMENTS & METHODS, 1981, 181 (1-3): : 259 - 261
  • [44] A proteomic analysis on human sperm tail: comparison between normozoospermia and asthenozoospermia
    Mahmoud Hashemitabar
    Susan Sabbagh
    Mahmoud Orazizadeh
    Atta Ghadiri
    Maryam Bahmanzadeh
    Journal of Assisted Reproduction and Genetics, 2015, 32 : 853 - 863
  • [45] COMPARISON OF MATHEMATICAL INDEXES OF FETAL HEART-RATE-VARIABILITY WITH VISUAL ASSESSMENT IN THE HUMAN AND SHEEP
    KNOPF, K
    PARER, JT
    ESPINOZA, MI
    HORTON, JIA
    GUNN, AJ
    WILLIAMS, CE
    GLUCKMAN, PD
    PARER, WJ
    JOURNAL OF DEVELOPMENTAL PHYSIOLOGY, 1991, 16 (06) : 367 - 372
  • [46] Automatic detection of maintenance requests: Comparison of Human Manual Annotation and Sentiment Analysis techniques
    D'Orazio, Marco
    Di Giuseppe, Elisa
    Bernardini, Gabriele
    AUTOMATION IN CONSTRUCTION, 2022, 134
  • [47] Comparison of techniques for time-frequency analysis of the ECG during human ventricular fibrillation
    Clayton, RH
    Murray, A
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1998, 145 (06) : 301 - 306
  • [48] Advanced microextraction techniques for the analysis of amphetamines in human breast milk and their comparison with conventional methods
    Piskackova, Hana Bavlovic
    Nemeskalova, Alzbeta
    Kucera, Radim
    Pedersen-Bjergaard, Stig
    Najmanova, Vera
    Sterbova-Kovarikova, Petra
    Kuchar, Martin
    Sykora, David
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 210
  • [49] COMPARISON BETWEEN SWIM-UP AND GLASS BEAD COLUMN TECHNIQUES FOR THE SEPARATION OF HUMAN SPERMATOZOA
    CALAMERA, JC
    QUIROS, MC
    BRUGO, S
    NICHOLSON, RF
    ANDROLOGIA, 1991, 23 (04) : 259 - 261
  • [50] An Empirical Study on Document Similarity Comparison Evaluation Between Machine Learning Techniques and Human Experts
    Jang, Won-Jung
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2024, 31 (05): : 1668 - 1679