Power balancing and dc fault ride through in DC grids with dc hubs and wind farms

被引:13
|
作者
Lin, Weixing [1 ]
Jovcic, Dragan [1 ]
机构
[1] Univ Aberdeen, Sch Engn, Aberdeen AB24 3UE, Scotland
基金
欧洲研究理事会;
关键词
HVDC;
D O I
10.1049/iet-rpg.2014.0401
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Power balancing algorithm and dc fault ride through strategy in a DC grid with a DC hub are proposed in this article. Inductor-capacitor-inductor (LCL) dc hub is used in the DC grid to match different voltage levels and to prevent DC fault spreading. An automatic power balancing control is developed for the hub controller, and for DC grid terminals including wind farms and passive AC loads. Collectively these controls enable power balancing for any DC fault without the need for hardware braking systems. The challenges of connecting/disconnecting of DC grid segments and a DC grid black start with non-isolated dc hubs are resolved with new controls and specific operating sequence. A 3-terminal test dc grid is developed using a 3-port LCL dc hub where one terminal is connected to a wind farm, another terminal is connected to an ac grid and a third terminal to a passive ac load. Simulations on this difficult test system are performed for a range of DC faults, power steps and a black start using PSCAD/EMTDC and results verify conclusions.
引用
收藏
页码:847 / 856
页数:10
相关论文
共 50 条
  • [31] The design and fault ride through control of un-interrupted DC-DC Autotransformer
    MengBo Li
    Wang Xiang
    WenPing Zuo
    LiangZhong Yao
    WeiXing Lin
    JinYu Wen
    Science China Technological Sciences, 2018, 61 : 1935 - 1949
  • [32] The design and fault ride through control of un-interrupted DC-DC Autotransformer
    Li MengBo
    Xiang Wang
    Zuo WenPing
    Yao LiangZhong
    Lin WeiXing
    Wen JinYu
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2018, 61 (12) : 1935 - 1949
  • [33] The design and fault ride through control of un-interrupted DC-DC Autotransformer
    LI MengBo
    XIANG Wang
    ZUO WenPing
    YAO LiangZhong
    LIN WeiXing
    WEN JinYu
    Science China(Technological Sciences), 2018, (12) : 1935 - 1949
  • [34] AC/DC fault handling and expanded DC power flow expression in hybrid multi-converter DC grids
    Sun, Pingyang
    Wickramasinghe, Harith R.
    Khalid, Muhammad
    Konstantinou, Georgios
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [35] Fault Ride-Through Capability of MMC Based Wind Power Plant Integrated Under a DC-Link Fault
    Mohammed, Inas M. O.
    Gitau, Michael Njoroge
    Bansal, Ramesh C.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2022, 50 (03) : 133 - 148
  • [36] Optimal Control and DC Fault Ride-Through of Transmission Level, MMC-Based, Isolated DC/DC Converter
    Jovcic, Dragan
    Zhang, Huibin
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [37] Chopperless Fault Ride-Through Control for DC Microgrids
    Xia, Yanghong
    Long, Teng
    IEEE TRANSACTIONS ON SMART GRID, 2021, 12 (02) : 965 - 976
  • [38] On Systematic DC Fault-Ride-Through of Multi-terminal MMC-HVDC Grids
    Niaki, Seyed Hassan Ashrafi
    Chen, Zhe
    Bak-Jensen, Birgitte
    Sharifabadi, Kamran
    Liu, Zhou
    Hu, Shuju
    2021 56TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC 2021): POWERING NET ZERO EMISSIONS, 2021,
  • [39] LCL DC/DC Converter for DC Grids
    Jovcic, Dragan
    Zhang, Lu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (04) : 2071 - 2079
  • [40] Fault ride through of fully rated converter wind turbines with AC and DC transmission systems
    Ramtharan, G.
    Arulampalam, A.
    Ekanayake, J. B.
    Hughes, F. M.
    Jenkins, N.
    IET RENEWABLE POWER GENERATION, 2009, 3 (04) : 426 - 438