Characterization of the high current triggered vacuum switch

被引:9
|
作者
Wu, Hao [1 ]
He, Zhenghao [1 ]
Guo, Runkai [1 ]
Ma, Jun [1 ]
Zhao, Huan [1 ]
Chen, Xi [1 ]
Chen, Weimin [1 ]
Xu, Taisheng [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
关键词
The main current; Coulomb; The delay time; Triggered vacuum switch (TVS); VOLTAGE; GAP;
D O I
10.1016/j.vacuum.2012.03.051
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The triggered vacuum switch (TVS) is widely used in the electromagnetic launcher (EML) system. An important performance of TVS with the six-gap rod electrode system which has been used in experimental research is long operating life, the high current and high coulomb. A major feature of TVS is capacity of carrying high current. Therefore, this paper focuses on the main current characteristics of the TVS. The result shows that under the capacitance of 1200 mu F, the experiment was repeated 300 times when the current flowing through TVS was 100 kA, the characteristic of TVS is not damaged, the trigger voltage is maintained at 4-5 kV, insulation resistance is 2000 M Omega. In another case, when the capacitor value is 4400 mu F, the current flowing through TVS was 207 kA, it can be repeated several times, until TVS is damaged, insulation resistance drops to 0 Omega. The result proves that the surface flashover triggered vacuum switch of a six-gap rod electrode can withstand 200 kA current, the transfer charge is 75 C. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1911 / 1915
页数:5
相关论文
共 50 条
  • [21] Limit Rate of Current Rise in Triggered Vacuum Switch
    Alferov, D. F.
    Londer, Ya I.
    Ulyanov, K. N.
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 258 - 261
  • [22] High coulomb triggered vacuum flashover switch
    Ford, RD
    Dorr, G
    Reams, R
    Toepfer, AJ
    11TH IEEE INTERNATIONAL PULSED POWER CONFERENCE - DIGEST OF TECHNICAL PAPERS, VOLS. 1 & 2, 1997, : 893 - 898
  • [23] A High-Voltage and High-Current Miniaturized Surface Flashover Triggered Vacuum Switch
    Zhang, Ming
    Liao, Minfu
    Lu, Gang
    Bu, Liang
    Yu, Longfei
    Sun, Yifan
    Duan, Xiongying
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2025, 53 (02) : 284 - 292
  • [24] STUDY OF RECOVERY PHENOMENA IN A HIGH-CURRENT PULSE-TRIGGERED VACUUM SWITCH
    BAUVILLE, G
    DELMAS, A
    HADDAD, N
    RIOUX, C
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1989, 17 (05) : 781 - 785
  • [25] Triggered vacuum switch-based fault current limiter
    Shi, Jing
    Zou, Jiyan
    He, Junjia
    IEEE Power Engineering Review, 2001, 21 (01): : 51 - 53
  • [26] Research on the Prebreakdown Current of the Laser-Triggered Vacuum Switch
    Huang, Zucheng
    Xiang, Bin
    Cao, Xiangwei
    Zong, Yun
    He, Zhenghao
    Mao, Xiaopo
    Zhang, Yaodong
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (02) : 410 - 414
  • [27] Characteristics of Triggered Vacuum Switch with Single Axial Magnetic Electrode for High Frequency Current Interruption
    Pu, Lu
    Cao, Xiaolong
    Duan, Xiongying
    Cheng, Xian
    Liao, Minfu
    2012 16TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC LAUNCH TECHNOLOGY (EML), 2012,
  • [28] Characteristics of Triggered Vacuum Switch with Single Axial Magnetic Electrode for High Frequency Current Interruption
    Duan, Xiongying
    Cheng, Xian
    Liao, Minfu
    Zou, Jiyan
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 232 - 235
  • [29] Characterization of a 30 kV, 75 C triggered vacuum switch
    Park, SS
    Nam, SH
    Han, YJ
    Son, BH
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2005, 33 (01) : 192 - 196
  • [30] CROWBARRED LOAD CURRENT CONTAINING NO RIPPLE COMPONENT WITH TRIGGERED VACUUM SWITCH
    ITAGAKI, K
    KITAMURA, H
    ELECTRICAL ENGINEERING IN JAPAN, 1977, 97 (04) : 26 - 31