Real dynamic assessment of tear film optical quality for monitoring and early prevention of dry eye

被引:9
|
作者
Wu, Ming-Feng [1 ]
Gao, Hui [1 ]
Zhao, Li-Jun [1 ]
Chen, Hua [1 ]
Huang, Yu-Kan [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Dept Ophthalmol, Wuhan, Peoples R China
关键词
break-up dynamics; dry eye; objective scatter index; optical quality; tear film; BREAK-UP; STABILITY;
D O I
10.1097/MD.0000000000021494
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate real dynamic assessment of tear film optical quality for monitoring and prevention of dry eye. Right eyes of 62 normal and 39 dry eye subjects were included. Dynamic measurement of objective scatter index (OSI) was performed by using the Optical Quality Analysis System II (OQAS II), correlation coefficient between OSI and time (CCOT) was calculated. According to whether the CCOT was significantly ascending, normal and dry eye groups were further subdivided for comparison. By using Scheimpflug-Placido topographer, non-invasive tear break-up time (NITBUT) was recorded, and a 2-dimensional precorneal tear film map was reconstructed and divided into central, middle, and peripheral corneal zones, distribution of tear break-up spots in the 3 corneal zones were analyzed. The numbers of tear break-up spots were higher in all the 3 corneal zones of the dry eye subjects (P < .01), when compared with the normal subjects. The Dry Eye subjects with ascending CCOT had the shortest NITBUT (P < .001-.034) and the most tear break-up spots over the whole cornea (P < .001-.044). Between the dry eye subjects with non-ascending CCOT and those with ascending CCOT, difference of tear break-up spots was found significant only in the peripheral corneal zone (P < .01). Non-ascending and ascending CCOT of dry eye patients reflect different stability of tear film. Real dynamic assessment of tear film optical quality is potential for monitoring and early prevention of dry eye.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The Tear Film and the Optical Quality of the Eye
    Montes-Mico, Robert
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Madrid-Costa, David
    OCULAR SURFACE, 2010, 8 (04): : 185 - 192
  • [2] Effect of dynamic changes in the tear film on the optical quality in normal and dry eyes
    Hedstrom, Johan
    Theagarayan, Baskar
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [3] Supporting Dry Eye Diagnosis with a New Method for Noninvasive Tear Film Quality Assessment
    Llorens-Quintana, Clara
    Szczesna-Iskander, Dorota
    Iskander, D. Robert
    OPTOMETRY AND VISION SCIENCE, 2019, 96 (02) : 103 - 110
  • [4] Objective optical assessment of tear-film quality dynamics in patients with meibomian gland dysfunction and aqueous-deficient dry eye optical quality changes in different dry eye subtypes
    Ye, Fen
    Jiang, Feng
    Lu, Yan
    Xue, Chun Yan
    Zhu, Xiao Min
    Wu, Yan
    Huang, Zhen Ping
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (05) : 599 - 603
  • [5] Assessment of tear film optical quality in a young short tear break-up time dry eye Case-control study
    Xi, Lei
    Qin, Jiayin
    Bao, Yongzhen
    MEDICINE, 2019, 98 (40)
  • [6] Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease
    An-Peng Pan
    Yunjing Ma
    Ruilin Hu
    Xuejiao Cao
    Yifen Wu
    Kaijing Zhou
    Ruixue Tu
    Xu Shao
    Shihao Chen
    A-Yong Yu
    Eye and Vision, 10
  • [7] Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease
    Pan, An-Peng
    Ma, Yunjing
    Hu, Ruilin
    Cao, Xuejiao
    Wu, Yifen
    Zhou, Kaijing
    Tu, Ruixue
    Shao, Xu
    Chen, Shihao
    Yu, A-Yong
    EYE AND VISION, 2023, 10 (01)
  • [8] Role of the tear film in the optical quality of the human eye
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (09): : 1631 - 1635
  • [9] Measuring the effect of the tear film on the optical quality of the eye
    Dubra, A
    Dainty, JC
    Paterson, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U469 - U469
  • [10] Assessment of Tear Film Optical Quality Dynamics
    Yu, A-Yong
    Lu, Ting
    Pan, An-Peng
    Lin, Duo-Ru
    Xu, Chen-Chen
    Huang, Jin-Hai
    Bao, Fang-Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (08) : 3821 - 3827