Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease

被引:5
|
作者
Pan, An-Peng [1 ]
Ma, Yunjing [1 ]
Hu, Ruilin [1 ]
Cao, Xuejiao [1 ]
Wu, Yifen [1 ]
Zhou, Kaijing [1 ]
Tu, Ruixue [1 ]
Shao, Xu [1 ]
Chen, Shihao [1 ]
Yu, A-Yong [1 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Natl Clin Res Ctr Ocular Dis, 270 Xueyuan West Rd, Wenzhou 325027, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Dry eye disease; Functional visual acuity; Tear film optical quality; Simultaneous real-time base; CONTACT-LENS INTERACTIONS; HIGHER-ORDER ABERRATIONS; SERIAL MEASUREMENTS; MEASUREMENT SYSTEM; OBJECTIVE SIGNS; OF-LIFE; SYMPTOMS; IMPACT; REPEATABILITY; EPIDEMIOLOGY;
D O I
10.1186/s40662-023-00333-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To assess the effect of tear film instability in dry eye disease (DED) by measuring visual performance and tear film optical quality in a simultaneous real-time analysis system. Methods Thirty-seven DED participants and 20 normal controls were recruited. A simultaneous real-time analysis system was developed by adding a functional visual acuity (FVA) channel to a double-pass system. Repeated measurements of FVA and objective scatter index (OSI) were performed simultaneously with this system under blink suppression condition for 20 s. Patient-reported symptoms was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. Mean FVA, mean OSI, and visual acuity break-up time were defined. The OSI maintenance ratio was calculated as an evaluation index to assess the difference between dynamic OSI changes and baseline OSI. The visual maintenance ratio was also calculated in the same way. Results Moderate correlations were noted between mean OSI and FVA-related parameters (mean FVA, visual maintenance ratio, visual acuity break-up time: 0.53, - 0.56, - 0.53, respectively, P < 0.01 for all). Moderate to high correlations were noted between OSI maintenance ratio and FVA-related parameters (mean FVA, visual maintenance ratio, visual acuity break-up time: - 0.62, 0.71, 0.64, respectively, all P < 0.01). The metrics derived from the simultaneous real-time analysis system were moderately correlated with the patient-reported symptoms and the visual acuity break-up time possessed the highest correlation coefficients with OSDI total, ocular symptoms, and vision-related function (- 0.64, - 0.63, - 0.62, respectively, P < 0.01). The OSI-maintenance ratio alone appeared to exhibit the best performance of the metrics for the detection of DED with sensitivity of 95.0% and specificity of 83.8% and the combinations of FVA parameters and OSI parameters were valid and can further improve the discriminating abilities. Conclusions OSI-related metrics were found to be potential indicators for assessing and diagnosing DED which correlated with both subjective visual performance and patient-reported symptoms; the FVA-related metrics were quantifiable indicators for evaluating visual acuity decline in DED.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease
    An-Peng Pan
    Yunjing Ma
    Ruilin Hu
    Xuejiao Cao
    Yifen Wu
    Kaijing Zhou
    Ruixue Tu
    Xu Shao
    Shihao Chen
    A-Yong Yu
    Eye and Vision, 10
  • [2] Functional visual acuity in dry eye disease
    Messmer, Elisabeth M.
    SPEKTRUM DER AUGENHEILKUNDE, 2021, 35 (05) : 143 - 149
  • [3] The Association of Dry Eye Disease with Functional Visual Acuity and Quality of Life
    Tan, Lydia Hui-Peng
    Tong, Louis
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
  • [4] Real dynamic assessment of tear film optical quality for monitoring and early prevention of dry eye
    Wu, Ming-Feng
    Gao, Hui
    Zhao, Li-Jun
    Chen, Hua
    Huang, Yu-Kan
    MEDICINE, 2020, 99 (31)
  • [5] Automated Tear Film Surface Quality Breakup Time as a Novel Clinical Marker for Tear Hyperosmolarity in Dry Eye Disease
    Downie, Laura Elizabeth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (12) : 7260 - 7268
  • [6] Optical Quality of the Eye Degraded by Time-Varying Wavefront Aberrations with Tear Film Dynamics
    Yoko Hirohara
    Toshifumi Mihashi
    Shizuka Koh
    Sayuri Ninomiya
    Naoyuki Maeda
    Takashi Fujikado
    Japanese Journal of Ophthalmology, 2007, 51 : 258 - 264
  • [7] Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics
    Hirohara, Yoko
    Mihashi, Toshifumi
    Koh, Shizuka
    Ninomiya, Sayuri
    Maeda, Naoyuki
    Fujikado, Takashi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2007, 51 (04) : 258 - 264
  • [8] Tear Film Aberration Dynamics and Vision-Related Quality of Life in Patients with Dry Eye Disease
    Denoyer, Alexandre
    Rabut, Ghislaine
    Baudouin, Christophe
    OPHTHALMOLOGY, 2012, 119 (09) : 1811 - 1818
  • [9] Optical Quality and Tear Film Analysis Before and After Intranasal Stimulation in Patients with Dry Eye Syndrome
    Passi, Samuel F.
    Brooks, Cassandra C.
    Thompson, Atalie C.
    Gupta, Preeya K.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1987 - 1992
  • [10] Simultaneous and real-time measurements of dynamic tear film thickness and upper and lower tear menisci
    Wang, J
    Aquavella, J
    Zhao, Y
    Chung, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46