Failure characteristics of multiple-component fibrin-based adhesives

被引:1
|
作者
Sierra, DH
Eberhardt, AW
Lemons, JE
机构
[1] Univ Alabama Birmingham, Sch Engn, Dept Biomed Engn, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Sch Dent, Dept Biomat, Birmingham, AL 35294 USA
来源
关键词
tissue adhesive; fracture mechanics; test methods; mechanical properties; fibrin;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A series of analyses were performed on fibrin-based adhesives to describe their failure characteristics. Two test methods were used: uniaxial, monotonic tensile testing of the bulk material, and blister testing using fresh porcine-source skin graft as the adherend. Two fibrin concentrations, high (HFC), and low (LFC), were used to investigate the effects of the gel matrix density upon mechanical properties. In tensile tests, fibrin gels strain hardened, as functions of percent strain and of strain rate. An increase in modulus of elasticity (E) was seen with increasing strain and strain rate at both tested fibrin concentrations. Mode I failure mechanisms were predominant. Both adhesives appeared to fracture from the outer edge to the interior of the specimen at slower strain rate tests. This trend reversed as strain rate increased, becoming a classic "cup and cone" ductile fracture. Syneresis occurred at both concentrations at lower strain rates, but was more pronounced for the LFC. Ultimate tensile strength and E were greater for the HFC than for the LFC at all strain rates, decreasing with increasing strain rate. In the blister test, the failure locus changed from cohesive to adhesive as the strain rate was increased for the HFC. Failure of fibrin gels likely occurs by percolation of the pressurized saline, displacing the entrapped liquid phase of the gel in regions of relatively low moduli and strength, leading to fracture of the matrix. For LFC, the overall fracture locus remained predominantly cohesive regardless of strain rate. Burst strength and failure energy were higher for HFC than for LFC. It would appear that fibrin acts more as a viscous liquid than a rubberlike/elastic material at lower concentrations because adhesive failures had a higher burst strength and fracture energy (Gc) than did cohesive failures. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [31] Multiple-component condensation strategies for combinatorial library synthesis
    Armstrong, RW
    Combs, AP
    Tempest, PA
    Brown, SD
    Keating, TA
    ACCOUNTS OF CHEMICAL RESEARCH, 1996, 29 (03) : 123 - 131
  • [32] Advances in Fibrin-Based Materials in Wound Repair: A Review
    Bayer, Ilker S.
    MOLECULES, 2022, 27 (14):
  • [33] THE STUDY OF ANGIOGENESIS IN FIBRIN-BASED TISSUE ENGINEERED CONSTRUCTS
    Frese, J.
    Motejlek, K.
    Schmitz-Rode, T.
    Neulen, J.
    Joeckenhoevel, S.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (07): : 418 - 418
  • [34] Transport Effects on Multiple-Component Reactions in Optical Biosensors
    Ryan M. Evans
    David A. Edwards
    Bulletin of Mathematical Biology, 2017, 79 : 2215 - 2241
  • [35] Modified block-replacement for multiple-component systems
    Archibald, TW
    Dekker, R
    IEEE TRANSACTIONS ON RELIABILITY, 1996, 45 (01) : 75 - 83
  • [36] Transport Effects on Multiple-Component Reactions in Optical Biosensors
    Evans, Ryan M.
    Edwards, David A.
    BULLETIN OF MATHEMATICAL BIOLOGY, 2017, 79 (10) : 2215 - 2241
  • [37] Resource-sharing in multiple-component working memory
    Doherty, Jason M.
    Logie, Robert H.
    MEMORY & COGNITION, 2016, 44 (08) : 1157 - 1167
  • [38] Single and multiple-component cryoprotective systems in Antarctic biota
    Montiel, PO
    CRYO-LETTERS, 1997, 18 (01) : 11 - 11
  • [39] Resource-sharing in multiple-component working memory
    Jason M. Doherty
    Robert H. Logie
    Memory & Cognition, 2016, 44 : 1157 - 1167
  • [40] Fibrin-based factor delivery for therapeutic angiogenesis: friend or foe?
    Ludovic Melly
    Andrea Banfi
    Cell and Tissue Research, 2022, 387 : 451 - 460