Feasibility of in vivo myelin water imaging using 3D multigradient-echo pulse sequences

被引:45
|
作者
Lenz, C. [1 ]
Klarhoefer, M. [1 ,2 ]
Scheffler, K. [1 ,3 ,4 ]
机构
[1] Univ Basel Hosp, Dept Radiol Phys, CH-4031 Basel, Switzerland
[2] Siemens Switzerland AG, Healthcare Sect, Zurich, Switzerland
[3] Max Planck Inst Biol Cybernet, High Field Magnet Resonance Ctr, Tubingen, Germany
[4] Univ Tubingen Hosp, Dept Neuroimaging & MR Phys, Tubingen, Germany
关键词
myelin water fraction; multigradient-echo pulse sequences; multiple sclerosis; non-negative least-squares algorithm; in vivo imaging; MULTIPLE-SCLEROSIS; RELAXATION-TIMES; BRAIN; VISUALIZATION;
D O I
10.1002/mrm.23241
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative myelin water imaging is able to show demyelinating processes and, therefore, provides insight into the pathology of white matter diseases such as multiple sclerosis. So far, mapping of the myelin water fraction most often was performed using single-slice multiecho spin-echo sequences. Recently, a different approach using two-dimensional multigradient-echo pulse sequences was suggested. In this work, a solution to three-dimensional in vivo myelin water fraction imaging is presented that applies multigradient-echo pulse sequences and uses non-negative least squares algorithms to analyze the multicomponent T*2 decay. The suggested method offers not only whole brain coverage but also clinically practicable acquisition times. The obtained myelin water fraction values are low (6.9% for white matter) but are able to detect demyelination in multiple sclerosis lesions. However, the clinical application of the proposed method remains questionable, because further measurements that clarify the possibility of detecting ongoing processes in lesions are needed. Magn Reson Med, 2012. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:523 / 528
页数:6
相关论文
共 50 条
  • [31] In Vivo visualization of white matter fiber tracts in the brainstem using low flip angle double echo 3D gradient echo imaging at 3T
    Xu, Qiuyun
    Chen, Yongsheng
    Miller, Stephan
    Bajaj, Kunal
    Santana, Jairo
    Badawy, Mohamed
    Lyu, Haiying
    Liu, Yu
    He, Naying
    Yan, Fuhua
    Haacke, E. Mark
    NEUROIMAGE, 2024, 300
  • [32] Feasibility and Validation of 4-D Pulse Wave Imaging in Phantoms and In Vivo
    Apostolakis, Iason-Zacharias
    Nauleau, Pierre
    Papadacci, Clement
    McGarry, Matthew D.
    Konofagou, Elisa E.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (09) : 1305 - 1317
  • [33] An Optimized 3D Spoiled Gradient Recalled Echo Pulse Sequence for Hemorrhage Assessment Using Inversion Recovery and Multiple Echoes (3D SHINE) for Carotid Plaque Imaging
    Zhu, David C.
    Vu, Anthony T.
    Ota, Hideki
    DeMarco, J. Kevin
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (05) : 1341 - 1351
  • [34] Blind Source Separation for Myelin Water Fraction Mapping Using Multi-Echo Gradient Echo Imaging
    Song, Jae Eun
    Shin, Jaewook
    Lee, Hongpyo
    Lee, Ho Joon
    Moon, Won-Jin
    Kim, Dong-Hyun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 2235 - 2245
  • [35] Monitoring radiofrequency ablation in ex vivo human liver using 3D echo decorrelation imaging augmented by deep learning
    Ghahramani Z, Elmira
    Grimm, Peter D.
    Wang, Jiang
    Ahmad, Syed A.
    Shah, Shimul A.
    Quillin, R. Cutler
    Patel, Sameer H.
    Rao, Marepalli B.
    Mast, T. Douglas
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [36] Perfusion Estimation Using 3D Subharmonic Imaging: an In Vivo Study
    Sridharan, Anush
    Eisenbrey, John R.
    Machado, Priscilla
    Liu, Ji-Bin
    Park, Suhyun
    Dianis, Scott
    Wallace, Kirk
    Thomenius, Kai E.
    Forsberg, Flemming
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1102 - 1105
  • [37] Accuracy and feasibility of online 3D echo for measurement of LV parameters
    Jenkins, C.
    Chan, J.
    Hanekom, L.
    Marwick, T. H.
    EUROPEAN HEART JOURNAL, 2005, 26 : 314 - 315
  • [38] In vivo reliability of 3D cephalometric landmark determination on magnetic resonance imaging: a feasibility study
    Juerchott, Alexander
    Freudlsperger, Christian
    Zingler, Sebastian
    Saleem, Muhammad Abdullah
    Jende, Johann M. E.
    Lux, Christopher J.
    Bendszus, Martin
    Heiland, Sabine
    Hilgenfeld, Tim
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (03) : 1339 - 1349
  • [39] In vivo reliability of 3D cephalometric landmark determination on magnetic resonance imaging: a feasibility study
    Alexander Juerchott
    Christian Freudlsperger
    Sebastian Zingler
    Muhammad Abdullah Saleem
    Johann M. E. Jende
    Christopher J. Lux
    Martin Bendszus
    Sabine Heiland
    Tim Hilgenfeld
    Clinical Oral Investigations, 2020, 24 : 1339 - 1349
  • [40] 3D GRADIENT ECHO CSF MYELOGRAPHY USING STEADY-STATE IMAGING
    VANDYKE, C
    BEALE, SM
    ROSS, JS
    MASARYK, TJ
    HAACKE, EM
    WIELOPOLSKI, P
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1989, 10 (04) : 900 - 900