Rapid and sensitive electrochemical monitoring of paracetamol and its simultaneous resolution in presence of epinephrine and tyrosine at GO/poly (Val) composite modified carbon paste electrode

被引:41
|
作者
Gopal, T. Venu [1 ]
Reddy, T. Madhusudana [1 ]
Venkataprasad, G. [1 ]
Shaikshavalli, P. [1 ]
Gopal, P. [1 ]
机构
[1] Sri Venkateswara Univ, Dept Chem, SVU Coll Sci, Electrochem Res Lab, Tirupati 517502, Andhra Prades, India
关键词
Paracetamol; L-Valine; Graphene oxide; Cyclic voltammetry; Differential pulse voltammetry; Electrochemical impedance spectroscopy; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; DOPED DIAMOND ELECTRODE; FOLIC-ACID; ASCORBIC-ACID; OXIDE NANOCOMPOSITE; URIC-ACID; SENSOR; ACETAMINOPHEN; DOPAMINE; NANOTUBES;
D O I
10.1016/j.colsurfa.2018.02.049
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Over the past few years physicists, chemists and material scientists showed a special interest on graphene and graphene oxide (GO) relative research. Recently, there is a sudden upsurge in the development of GO based sensors, which was due to their eminent properties like fast electronic transfer rate, large surface area, high stability and excellent conductivity nature, enabled them for the sensitive determination of different analytes. In our present investigation, L-Valine was electropolymerized onto the clear surface of carbon paste electrode (poly (Val)/CPE) with the help of cyclic voltammetry (CV) technique. Later GO was immobilised onto the surface of poly(Val)/CPE, which showed enhanced electrocatalytic activity towards the determination paracetamol (PC) in comparison with bare CPE, GO/CPE and poly(Val)/CPE respectively in 0.1 M phosphate buffer solution (PBS) of pH 7.0. The surface morphology of different modified electrodes was studied with the help of scanning electron microscopy (SEM). The limit of detection (LOD) and limit of quantification (LOQ) values for PC were determined with the help of differential pulse voltammetry (DPV) and were found to be as 0.29 mu M and 0.96 mu M respectively. The effect of pH, scan rate and concentration of PC was studied in detail. The electron transfer efficiency of different fabricated electrodes was studied by electrochemical impedance spectroscopy (EIS). The simultaneous resolution of PC, epinephrine (EP) and tyrosine (TY) was achieved with the help of DPV technique at GO/poly (Val)/CPE. The obtained results suggest that the fabricated composite chemical sensor GO/poly(Val)/CPE has satisfactory electroanalytical performance. The proposed investigation method was successfully applied towards the determination of PC in pharmaceutical and human serum samples.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 50 条
  • [1] Rapid Electrochemical Monitoring of Tyrosine by Poly (Riboflavin) Modified Carbon Nanotube Paste Electrode as a Sensitive Sensor and its Applications in Pharmaceutical Samples
    D'Souza, Edwin Santhan
    Manjunatha, Jamballi G.
    Chenthattil, Raril
    Tigari, Girish
    Ravishankar, Doddarasinakere K.
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2021, 11 (06): : 14661 - 14672
  • [2] Electrochemical sensing of paracetamol and its simultaneous resolution in the presence of dopamine and folic acid at a multi-walled carbon nanotubes/poly(glycine) composite modified electrode
    Narayana, P. V.
    Reddy, T. Madhusudana
    Gopal, P.
    Naidu, G. Ramakrishna
    ANALYTICAL METHODS, 2014, 6 (23) : 9459 - 9468
  • [3] Electrochemical Behaviour of Norepinephrine in the Presence of Paracetamol and Folic Acid at Poly (Congo red) Modified Carbon Paste Electrode
    Kuskur, Chethan Maheshwarappa
    Swamy, Bahaddurghatta Eshwaraswamy Kumara
    Jayadevappa, Honnali
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 658 - 674
  • [4] A Sensitive Simultaneous Determination of Epinephrine and Tyrosine using an Iron(III) Doped Zeolite-Modified Carbon Paste Electrode
    Babaei, Ali
    Mirzakhani, Somaieh
    Khalilzadeh, Balal
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (10) : 1862 - 1869
  • [6] Electroanalysis and simultaneous determination of dopamine and epinephrine at poly(isonicotinic acid)-modified carbon paste electrode in the presence of ascorbic acid
    Zhou, Yuan Zhen
    Zhang, Li Juan
    Chen, Shuang Li
    Dong, She Ying
    Zheng, Xiao Hui
    CHINESE CHEMICAL LETTERS, 2009, 20 (02) : 217 - 220
  • [7] Poly (L-leucine) modified carbon paste electrode as an electrochemical sensor for the detection of paracetamol in presence of folic acid
    Naik T.S.S.K.
    Swamy B.E.K.
    Ramamurthy P.C.
    Chetankumar K.
    Materials Science for Energy Technologies, 2020, 3 : 626 - 632
  • [8] Simultaneous Resolution and Electrochemical Quantification of Tyrosine and Tryptophan at a Poly (Diphenylamine) Modified Electrode
    Krishnan, Rajasree G.
    Saraswathyamma, Beena
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (02)
  • [9] Electrochemical sensor based on poly (aspartic acid) modified carbon paste electrode for paracetamol determination
    Islam, Mohammed Monirul
    Arifuzzaman, Md
    Rushd, Sayeed
    Islam, Md Kamrul
    Rahman, Muhammad Muhitur
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (02):
  • [10] Electrochemical Studies of Paracetamol at Poly (Aniline Blue) Modified Carbon Paste Electrode: A Voltammetric Study
    Vishwanath, Chandrashekar C.
    Swamy, Bahaddurghatta E. Kumara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (05): : 573 - 582