Optimum Accuracy of Two-Dimensional Strain Measurements Using Digital Image Correlation

被引:33
|
作者
Lee, Chris [1 ]
Take, W. Andy [2 ]
Hoult, Neil A. [2 ]
机构
[1] Queens Univ, Fac Engn & Appl Sci, Kingston, ON K7L 3N6, Canada
[2] Queens Univ, Dept Civil Engn, Kingston, ON K7L 3N6, Canada
关键词
Strain gauges; Imaging techniques; Monitoring; Tests; Structural behavior;
D O I
10.1061/(ASCE)CP.1943-5487.0000182
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Foil and vibrating wire strain gauges have an optimum strain measurement accuracy of one microstrain. However, they can only provide discrete strain readings over a single fixed-gauge length. Digital image correlation (DIC) offers an alternative to conventional strain gauges because a two-dimensional (2D) surface strain field can be obtained from a single sensor (camera). However, the benefits of 2D strain measurements are only worthwhile if a similar level of measurement accuracy to conventional strain gauges can be achieved. This paper presents the results of an investigation into the optimum strain measurement accuracy that can be achieved by using the 2D technique on artificial images (which eliminate errors associated with cameras and lighting). The principle of the 2D DIC technique and its historical development will be introduced. Then, three potential techniques for taking strain measurements will be presented and compared: single readings, averaged linear readings, and an approach on the basis of Mohr's circle. The Mohr's circle approach was found to be the most accurate and was not susceptible to image misalignment. Strain measurement accuracy was also found to be affected by the bias error of the subpixel interpolation scheme, but the use of an 8 coefficient B-spline was found to produce satisfactory results within the error of conventional strain gauges. Gauge length was also found to have a significant effect on strain measurement accuracy, indicating that measuring strains in a material in which there are variations across the strain field could result in a loss of measurement accuracy. However, overall it was found that 2D DIC offers the same strain measurement accuracy as conventional strain gauges when used under ideal conditions. DOI:10.1061/(ASCE)CP.1943-5487.0000182. (C) 2012 American Society of Civil Engineers.
引用
收藏
页码:795 / 803
页数:9
相关论文
共 50 条
  • [31] Characterization of delamination failure of two-dimensional horseshoe stretchable interconnects using digital image correlation
    Chen, Cheng
    Chen, Shaoxuan
    Gu, Wanghang
    Zhang, Hongru
    Liu, Bing
    POLYMER TESTING, 2021, 94
  • [32] TENSILE TESTING OF FLAT THIN SPECIMENS USING THE TWO-DIMENSIONAL DIGITAL IMAGE CORRELATION METHOD
    Mitrovic, Nenad
    Mitrovic, Aleksandra
    Travica, Milan
    STRUCTURAL INTEGRITY AND LIFE-INTEGRITET I VEK KONSTRUKCIJA, 2023, 23 (01): : 9 - 13
  • [33] The Digital Image Correlation System Accuracy Direct Testing Using Strain Gauges
    Rutkiewicz, Andrzej
    Jakobczak, Artur
    2017 BALTIC GEODETIC CONGRESS (BGC GEOMATICS), 2017, : 369 - 373
  • [34] Image dehazing using two-dimensional canonical correlation analysis
    Wang, Liqian
    Xiao, Liang
    Wei, Zhihui
    IET COMPUTER VISION, 2015, 9 (06) : 903 - 913
  • [35] Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation
    Sutton, M.A.
    Ke, X.
    Lessner, S.M.
    Goldbach, M.
    Yost, M.
    Zhao, F.
    Schreier, H.W.
    Journal of Biomedical Materials Research - Part A, 2008, 84 (01) : 178 - 190
  • [36] Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation
    Sutton, M. A.
    Ke, X.
    Lessner, S. M.
    Goldbach, M.
    Yost, M.
    Zhao, F.
    Schreier, H. W.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 84A (01) : 178 - 190
  • [37] Research on high-accuracy two-dimensional digital image correlation hardware measurement systems used in the engineering practice
    Chen Guang
    Ding Keqin
    Feng Qibo
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS III, 2014, 9276
  • [38] Influence of Camera's Optical Axis Non-perpendicularity on Measurement Accuracy of Two-dimensional Digital Image Correlation
    Hijazi, A.
    Friedl, A.
    Kaehler, C. J.
    JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2011, 5 (04): : 373 - 382
  • [39] Two-dimensional digital image correlation for asphalt mixture characterisation: interest and limitations
    Romeo, Elena
    ROAD MATERIALS AND PAVEMENT DESIGN, 2013, 14 (04) : 747 - 763
  • [40] Comparison of Two-Dimensional Fields Generated by Numerical Simulation and Digital Image Correlation
    Grinevich D.V.
    Yakovlev N.O.
    Slavin A.V.
    Vlasov I.I.
    Russian Engineering Research, 2023, 43 (01) : 21 - 26