The Traceability Improvement and Comparison of Bell Prover as the Indonesian National Standard of Gas Volume Flow Rate

被引:3
|
作者
Prakosa, J. A. [1 ]
Su, C. M. [2 ]
Wang, W. B. [2 ]
Sirenden, B. H. [1 ]
Zaid, G. [3 ]
Darmayanti, N. C. E. [3 ]
机构
[1] Indonesian Inst Sci LIPI, Res Ctr Phys, Tangerang Selatan 15314, Banten, Indonesia
[2] Ind Technol Res Inst ITRI, Ctr Measurement Stand CMS, 30 Ta Hsueh Rd, Hsinchu 30080, Taiwan
[3] Natl Standardizat Agcy Indonesia BSN, Tangerang Selatan 15314, Banten, Indonesia
来源
关键词
Improvement; Traceability; Comparison; Bell prover; Gas flow rate; Turbine;
D O I
10.1007/s12647-020-00402-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Traceability is urgent to guarantee the truth of measurement, particularly for National Standard. Although a bell prover facility has established as the national low pressure gas flow standard of Indonesia since 2008, the measurement capability (15 to 1400 L/min, U-95 = 0.20%) of the bell prover has not been traceable to SI Units. Moreover, displacement values provided by the bell prover's manufacturer by rotary encoder method are still used. The limit detector by optical sensor to measure displacement is worthy to achieve dimensional traceability which can be switched by ultrasonic sensor for reasonable solution. The aim of this study is to improve the traceability of the bell prover by reasonable solution and then validate the gas volume flow rate measurement by inter-laboratory comparison. The Center for Measurement Standards (CMS), Industrial Technology Research Institute (ITRI), was invited to participate in the bilateral comparison, and a gas turbine flow meter was used as the transfer standard. The bell prover has been successfully traceable to SI units, particularly displacement measurement through flying start/stop method by limit of ultrasonic sensor (250 to 1200 L/min, U-95 = 0.80% passing assessment report). Despite having larger uncertainty than manufacturer specification, the results are better for more in of layer comparison. Because the effect of turbine drift should be a concern, the gap of measurement time for inter-laboratory comparison is recommended to minimize as many as possible. Furthermore, the measurement range of bell prover should be reduced as reasonability purpose.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 50 条
  • [21] CALCULATION AND MEASUREMENT OF THE VOLUME FLOW-RATE DEPENDENCE OF TURBOMOLECULAR PUMPS ON THE TYPE OF GAS
    REICH, G
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1989, 7 (03): : 2365 - 2368
  • [22] CALCULATION AND MEASUREMENT OF THE VOLUME FLOW-RATE DEPENDENCE OF TURBOMOLECULAR PUMPS ON THE TYPE OF GAS
    REICH, G
    VAKUUM-TECHNIK, 1989, 38 (1-2): : 3 - 8
  • [23] Volume flow rate measurement for process control in gas-fired shuttle kilns
    Maier, P
    CFI-CERAMIC FORUM INTERNATIONAL, 1996, 73 (09): : 498 - &
  • [24] ANALYSIS OF BELL-TYPE VOLUME-DYNAMIC SYSTEMS USED FOR EXACT REPRODUCTION AND MEASUREMENT OF GAS-FLOW
    BRODIN, IS
    CHEKOVSKII, SA
    MEASUREMENT TECHNIQUES, 1977, 20 (06) : 832 - 836
  • [25] ON THE ACCURACY OF LOW FLOW-RATE GAS CALIBRATIONS AT THE NATIONAL-BUREAU-OF-STANDARDS
    POTZICK, J
    ISA TRANSACTIONS, 1986, 25 (02) : 19 - 24
  • [26] A National Comparison of Volume and Acuity for Adult and Pediatric Trauma: A Trauma Quality Improvement Program Cohort Study
    Thornton, Steven W.
    Leraas, Harold J.
    Horne, Elizabeth
    Cerullo, Marcelo
    Chang, Doreen
    Greenwald, Emily
    Agarwal, Suresh
    Haines, Krista L.
    Tracy, Elisabeth T.
    JOURNAL OF SURGICAL RESEARCH, 2023, 291 : 633 - 639
  • [27] Effect of gas flow rate and discharge volume on CO2 methanation with plasma catalysis
    Toko, Susumu
    Ideguchi, Masashi
    Hasegawa, Taiki
    Okumura, Takamasa
    Kamataki, Kunihiro
    Takenaka, Kosuke
    Koga, Kazunori
    Shiratani, Masaharu
    Setsuhara, Yuichi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (SI)
  • [28] Influence of ionization volume and sample gas flow rate on separation power in gas chromatography-ion mobility spectrometry
    Kobelt, Tim
    Lippmann, Martin
    Wuttke, Jannik
    Wessel, Hanno
    Zimmermann, Stefan
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1713
  • [29] Influence of gas flow rate on the synthesis of gas hydrate of freon 134a by the method of explosive boiling of liquefied gas in water volume
    Meleshkin, A., V
    Bartashevich, M., V
    Kozlov, A. N.
    XXXV SIBERIAN THERMOPHYSICAL SEMINAR, 2019, 2019, 1382
  • [30] National Primary Standard get 118-2013 for the Units of Volumetric and Mass Gas Flow Rates
    A. V. Mingaleev
    A. I. Gorchev
    V. A. Fafurin
    N. I. Mikheev
    Measurement Techniques, 2015, 58 : 115 - 120