RF - Plasma Source Commissioning in Indian Negative Ion Facility

被引:14
|
作者
Singh, M. J. [1 ]
Bandyopadhyay, M. [1 ]
Bansal, G.
Gahlaut, A.
Soni, J.
Kumar, Sunil
Pandya, K.
Parmar, K. G.
Sonara, J.
Yadava, Ratnakar [1 ]
Chakraborty, A. K. [1 ]
Kraus, W.
Heinemann, B.
Riedl, R.
Obermayer, S.
Martens, C.
Franzen, P.
Fantz, U.
机构
[1] ITER India, Inst Plasma Res, GIDC, A-29,Sect 25, Gandhinagar, Gujrat, India
关键词
RF generator; plasma source; matching network;
D O I
10.1063/1.3637432
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The Indian program of the RF based negative ion source has started off with the commissioning of ROBIN, the inductively coupled RF based negative ion source facility under establishment at Institute for Plasma research (IPR), India. The facility is being developed under a technology transfer agreement with IPP Garching. It consists of a single RF driver based beam source (BATMAN replica) coupled to a 100 kW, 1 MHz RF generator with a self excited oscillator, through a matching network, for plasma production and ion extraction and acceleration. The delivery of the RF generator and the RF plasma source without the accelerator, has enabled initiation of plasma production experiments. The recent experimental campaign has established the matching circuit parameters that result in plasma production with density in the range of 0.5 - 1 x 10(18) / m(3), at operational gas pressures ranging between 0.4 - 1 Pa. Various configurations of the matching network have been experimented upon to obtain a stable operation of the set up for RF powers ranging between 25 - 85 kW and pulse lengths ranging between 4-20 s. It has been observed that the range of the parameters of the matching circuit, over which the frequency of the power supply is stable, is narrow and further experiments with increased number of turns in the coil are in the pipeline to see if the range can be widened. In this paper, the description of the experimental system and the commissioning data related to the optimisation of the various parameters of the matching network, to obtain stable plasma of required density, are presented and discussed.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Plasma impedance measurement of uncesiated RF-driven negative hydrogen ion source in CSNS
    Li, H.
    Chen, W.
    Zhu, R.
    Xue, K.
    Liu, S.
    Cao, X.
    Lv, Y.
    Xiao, Y.
    Ouyang, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 996
  • [32] Hefei utility negative ions test equipment with RF source: commissioning and first results
    Wei, Jianglong
    Xie, Yahong
    Jiang, Caichao
    Liang, Lizhen
    Cui, Qinglong
    Chen, Shiyong
    Xu, Yongjian
    Wang, Yan
    Zhang, Li
    Xie, Yuanlai
    Hu, Chundong
    PLASMA SCIENCE & TECHNOLOGY, 2018, 20 (12)
  • [33] Hefei utility negative ions test equipment with RF source: commissioning and first results
    韦江龙
    谢亚红
    将才超
    梁立振
    崔庆龙
    陈世勇
    许永建
    王艳
    张黎
    谢远来
    胡纯栋
    Plasma Science and Technology, 2018, (12) : 129 - 135
  • [34] Hefei utility negative ions test equipment with RF source: commissioning and first results
    韦江龙
    谢亚红
    将才超
    梁立振
    崔庆龙
    陈世勇
    许永建
    王艳
    张黎
    谢远来
    胡纯栋
    Plasma Science and Technology, 2018, 20 (12) : 129 - 135
  • [35] System Integration of RF based Negative Ion Experimental Facility at IPR
    Bansal, G.
    Bandyopadhyay, M.
    Singh, M. J.
    Gahlaut, A.
    Soni, J.
    Pandya, K.
    Parmar, K. G.
    Sonara, J.
    Chakraborty, A.
    23RD NATIONAL SYMPOSIUM ON PLASMA SCIENCE AND TECHNOLOGY (PLASMA-2008), 2010, 208
  • [36] Commissioning of the ECR ion source of the high intensity proton injector of the Facility for Antiproton and Ion Research (FAIR)
    Tuske, O.
    Chauvin, N.
    Delferriere, O.
    Fils, J.
    Gauthier, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (05):
  • [37] Global model for an rf hydrogen inductive plasma discharge in the deuterium negative ion source experiment including negative ions
    Zorat, R
    Vender, D
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2000, 33 (14) : 1728 - 1735
  • [38] Commissioning of the mVINIS ion source
    Dobrosavljevic, A
    Draganic, I
    Dekic, S
    Stalevski, T
    Efremov, A
    Kutner, V
    Yazvitsky, N
    CYCLOTRONS AND THEIR APPLICATIONS 1998, 1999, : 443 - 446
  • [39] Deuterium results at the negative ion source test facility ELISE
    Kraus, W.
    Wuenderlich, D.
    Fantz, U.
    Heinemann, B.
    Bonomo, F.
    Riedl, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (05):
  • [40] Investigation of plasma chamber erosion in an RF ion source
    George, A.
    Melanson, S.
    Dehnel, M.
    Hoehr, C.
    20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743