RF - Plasma Source Commissioning in Indian Negative Ion Facility

被引:14
|
作者
Singh, M. J. [1 ]
Bandyopadhyay, M. [1 ]
Bansal, G.
Gahlaut, A.
Soni, J.
Kumar, Sunil
Pandya, K.
Parmar, K. G.
Sonara, J.
Yadava, Ratnakar [1 ]
Chakraborty, A. K. [1 ]
Kraus, W.
Heinemann, B.
Riedl, R.
Obermayer, S.
Martens, C.
Franzen, P.
Fantz, U.
机构
[1] ITER India, Inst Plasma Res, GIDC, A-29,Sect 25, Gandhinagar, Gujrat, India
关键词
RF generator; plasma source; matching network;
D O I
10.1063/1.3637432
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The Indian program of the RF based negative ion source has started off with the commissioning of ROBIN, the inductively coupled RF based negative ion source facility under establishment at Institute for Plasma research (IPR), India. The facility is being developed under a technology transfer agreement with IPP Garching. It consists of a single RF driver based beam source (BATMAN replica) coupled to a 100 kW, 1 MHz RF generator with a self excited oscillator, through a matching network, for plasma production and ion extraction and acceleration. The delivery of the RF generator and the RF plasma source without the accelerator, has enabled initiation of plasma production experiments. The recent experimental campaign has established the matching circuit parameters that result in plasma production with density in the range of 0.5 - 1 x 10(18) / m(3), at operational gas pressures ranging between 0.4 - 1 Pa. Various configurations of the matching network have been experimented upon to obtain a stable operation of the set up for RF powers ranging between 25 - 85 kW and pulse lengths ranging between 4-20 s. It has been observed that the range of the parameters of the matching circuit, over which the frequency of the power supply is stable, is narrow and further experiments with increased number of turns in the coil are in the pipeline to see if the range can be widened. In this paper, the description of the experimental system and the commissioning data related to the optimisation of the various parameters of the matching network, to obtain stable plasma of required density, are presented and discussed.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Structure design and analysis of RF ion source for negative ion source test facility
    Gu, Yuming
    Xie, Yahong
    Wei, Jianglong
    Xu, Yongjian
    Li, Jun
    Jiang, Caichao
    Liang, Lizhen
    Xie, Yuanlai
    Hu, Chundong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (11):
  • [2] Commissioning of two RF operation modes for RF negative ion source experimental setup at HUST
    Li, D.
    Chen, D.
    Liu, K.
    Zhao, P.
    Zuo, C.
    Wang, X.
    Wang, H.
    Zhang, L.
    FIFTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2016), 2017, 1869
  • [3] Efficient cesiation in RF driven surface plasma negative ion source
    Belchenko, Yu.
    Ivanov, A.
    Konstantinov, S.
    Sanin, A.
    Sotnikov, O.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [4] Negative Ion Production in the RF Multiaperture Surface-Plasma Source
    Abdrashitov, G.
    Belchenko, Yu.
    Dranichnikov, A.
    Ivanov, A.
    Gorbovsky, A.
    Kapitonov, V.
    Kolmogorov, V.
    Kondakov, A.
    Konstantinov, S.
    Sanin, A.
    Selivanov, A.
    Selivanov, P.
    Shikhovtsev, I.
    Sotnikov, O.
    Stupishin, N.
    Tiunov, M.
    Binderbauer, M.
    Putvinski, S.
    Smirnov, A.
    Sevier, L.
    FOURTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2014), 2015, 1655
  • [5] A negative ion source test facility
    Melanson, S.
    Dehnel, M.
    Potkins, D.
    Theroux, J.
    Hollinger, C.
    Martin, J.
    Philpott, C.
    Stewart, T.
    Jackle, P.
    Williams, P.
    Brown, S.
    Jones, T.
    Coad, B.
    Withington, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [6] Status of an RF negative hydrogen ion source using transformer coupled plasma source
    Hong, IS
    Jung, HD
    Park, YS
    Hwang, YS
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS, 2002, 639 : 61 - 66
  • [7] Over 7200 hours commissioning of RF-driven negative hydrogen ion source developed at CSNS
    Chen, W.
    Li, H.
    Lu, Y. J.
    Cao, X. X.
    Liu, S. J.
    Xiao, Y. C.
    Liao, H.
    Xue, K. J.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (04)
  • [8] Plasma characteristics of a large rf-driven negative hydrogen ion source
    Takanashi, T
    Takeiri, Y
    Kaneko, O
    Oka, Y
    Tsumori, K
    Kuroda, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1996, 35 (4A): : 2356 - 2362
  • [9] Characterization of the hydrogen plasma in the RF negative ion source by optical emission spectroscopy
    Li, Zengshan
    Yang, Jinghan
    Li, Dong
    Chen, Peng
    Zuo, Chen
    Chen, Dezhi
    PHYSICA SCRIPTA, 2023, 98 (04)
  • [10] A high-intensity, RF plasma-sputter negative ion source
    Alton, GD
    Lohwasser, R
    Cui, B
    Bao, Y
    Zhang, T
    Reed, CA
    HEAVY ION ACCELERATOR TECHNOLOGY, 1999, 473 : 341 - 351