Automated blood pressure measurement during ergometric stress testing: Possibilities of Finapres

被引:0
|
作者
Imholz, BPM
机构
来源
ZEITSCHRIFT FUR KARDIOLOGIE | 1996年 / 85卷
关键词
ergometry; blood pressure; continuous measurement; non-invasive measurement;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The accurate recording of the blood pressure response to ergometry is of increasing interest in clinical practice, yet its measurement is susceptible to considerable error. We searched the literature for studies that describe devices designed for automated measurement of indirect blood pressure during dynamic exercise. As a possible alternative we studied in seven normotensive subjects noninvasive continuous finger arterial and simultaneously recorded intrabrachial pressure before,during and after maximal bicycle ergometry to 220 - 340 watts. Results: The automated devices designed to pick up the Korotkoff sounds, even with support of R-wave EKG detection, amplification of K-sounds and/or implementation of microprocessor technology did not achieve the accuracy of conventional Riva-Rocci-Korotkoff sphygmomanometry. At maximal exercise brachial systolic, diastolic and mean responses were 67 +/- 20, 13 +/- 7 mm Hg and 35 +/- 13 respectively. In the finger systolic pressure increased significantly more (85 +/- 29 mm Hg, p < 0.05) but comparable responses were found for diastolic and mean pressure (18 +/- 12 mm Hg and 36 +/- 18). Conclusions: Automated blood pressure devices are not an improvement over conventional auscultatory measurement. Finger blood pressure can be measured even at maximal exercise, with a reliable continuous measurement of intrabrachial responses for mean and diastolic pressures.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [41] Automated Blood Pressure Measurement: Reasons for Measurement Variability Uncovered
    Zheng, D.
    Amoore, J. N.
    Mieke, S.
    Smith, F. E.
    King, S. T.
    Murray, A.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 21 - +
  • [43] INDIRECT MEASUREMENT OF BLOOD-PRESSURE DURING EXERCISE TESTING CAN BE MISLEADING
    GOULD, BA
    HORNUNG, RS
    ALTMAN, DG
    CASHMAN, PMM
    RAFTERY, EB
    BRITISH HEART JOURNAL, 1985, 53 (06): : 611 - 615
  • [44] ABC of hypertension - Blood pressure measurement - Part III - Automated sphygmomanometry: ambulatory blood pressure measurement
    O'Brien, E
    Beevers, G
    Lip, GYH
    BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7294): : 1110 - 1114
  • [45] Comparison of automated office blood pressure measurement with 24-hour ambulatory blood pressure measurement
    Peeters, Laura E. J.
    van Oortmerssen, Julie A. E.
    Derks, Lieke H.
    den Hertog, Heleen
    Fonville, Susanne
    Verboon, Christine
    Rietdijk, Wim J. R.
    Boersma, Eric
    Koudstaal, Peter J.
    van den Meiracker, Anton H.
    Versmissen, Jorie
    BLOOD PRESSURE, 2022, 31 (01) : 9 - 18
  • [46] ABC of hypertension - Blood pressure measurement - Part IV - Automated sphygmomanometry: self blood pressure measurement
    O'Brien, E
    Beevers, G
    Lip, GEH
    BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7295): : 1167 - 1170
  • [47] ASSESSMENT OF BLOOD-PRESSURE RESPONSE DURING ERGOMETRIC WORK IN NORMOTENSIVE AND HYPERTENSIVE PATIENTS
    FRANZ, IW
    ACTA MEDICA SCANDINAVICA, 1982, : 35 - 47
  • [48] PULMONARY ARTERY PRESSURE AND CARDIAC MINUTE VOLUMES DURING ERGOMETRIC STRESS IN INCREASING HYPOXIA
    WEIDEMANN, H
    ROSKAMM, H
    BLUMCHEN, G
    SCHNELLBACHER, K
    LANDRY, F
    PETERSEN, J
    LONNE, E
    REINDELL, H
    ZEITSCHRIFT FUR KREISLAUFFORSCHUNG, 1969, 58 (07): : 795 - +
  • [49] Prognostic significance of systolic blood pressure during exercise stress testing - Reply
    Gupta, Manish P.
    Polena, Sotir
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (10): : 1518 - 1519
  • [50] EFFICIENCY OF INDIRECT BLOOD PRESSURE DETERMINATIONS IN REST AND CIRCULATORY STRESS BY ERGOMETRIC WORK .1.
    KLEINHANSS, G
    JURGL, S
    PASSMANN, U
    ZEITSCHRIFT FUR KREISLAUFFORSCHUNG, 1971, 60 (02): : 136 - +