Development of a remote laser scanning system for continuous monitoring of cable-stayed bridges

被引:0
|
作者
Miyashita, T. [1 ]
Miyamoto, N. [1 ]
Umemoto, S. [1 ]
Fujino, Y. [1 ]
机构
[1] Nagaoka Univ Technol, Nagaoka, Niigata, Japan
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Conventional vibration measurement usually utilizes accelerometers. They are attached to selected measurement positions of a structure and wired to other equipments such as amplifiers and PC. At long-span cable-stayed or suspension bridges, measurement works involve the installation of sensors at high ground levels. Therefore, it is strongly needed to reduce the dangerous works and improve their efficiency. In this research, a non-contact and remote laser scanning system, which is the combination of a Laser Doppler Vibrometer (LDV) and a Total Station (TS), was developed. At first, the developed system was evaluated at selected bridges. Then, in order to examine the practicality of the system, it was applied into measuring vibration of the Tatara bridge. As a result, the developed system is expected to apply continuous vibration monitoring of the whole long-span bridges.
引用
收藏
页码:2549 / 2556
页数:8
相关论文
共 50 条
  • [31] Towards a standard policy for structural monitoring in cable-stayed bridges
    Astiz, M. A.
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 23 - 38
  • [32] Acoustic emission monitoring of CFRP cables for cable-stayed bridges
    Rizzo, P
    di Scalea, FL
    HEALTH MONITORING AND MANAGEMENT OF CIVIL INFRASTRUCTURE SYSTEMS, 2001, 4337 : 129 - 138
  • [33] Development of an Automated Wireless Tension Force Estimation System for Cable-stayed Bridges
    Cho, Soojin
    Lynch, Jerome P.
    Lee, Jong-Jae
    Yun, Chung-Bang
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2010, 21 (03) : 361 - 376
  • [34] Development of BIM-based bridge maintenance system for cable-stayed bridges
    Shire, Chang-su
    Kang, Hwirang
    Dang, Ngoc Son
    Lee, Deokkeun
    SMART STRUCTURES AND SYSTEMS, 2017, 20 (06) : 697 - 708
  • [35] Vibration control of cable-stayed bridges: Control system development and experimental results
    Shoureshi, RA
    Bell, MJ
    ENGINEERING MECHANICS: PROCEEDINGS OF THE 11TH CONFERENCE, VOLS 1 AND 2, 1996, : 902 - 905
  • [37] Dynamic testing of cable-stayed bridges
    Cases, JR
    STRUCTURAL ENGINEERING IN THE 21ST CENTURY, 1999, : 324 - 327
  • [38] Analysis of cables in cable-stayed bridges
    Santos, I. C.
    Caetano, E. S.
    Brito, J. L. V.
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 564 - 564
  • [39] Structural stability of cable-stayed bridges
    Kim, Seungjun
    Won, Deok Hee
    Lee, Keesei
    Kang, Young Jong
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2015, 15 (03) : 743 - 760
  • [40] BIBLIOGRAPHY AND DATA ON CABLE-STAYED BRIDGES
    SUBRAMANIAN, N
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1978, 104 (09): : 1539 - 1540