A mathematical modeling of pulsatile flow in carotid artery bifurcation

被引:6
|
作者
Agarwal, Ruchi [1 ]
Katiyar, V. K. [2 ]
Pradhan, Prabhakar [1 ]
机构
[1] Gurukul Kangari Univ, Dept Math, Haridwar 249404, India
[2] Indian Inst Technol, Dept Math, Roorkee 247667, Uttar Pradesh, India
关键词
Deformation; Pulsatile flow; Impedance; Carotid Artery;
D O I
10.1016/j.ijengsci.2008.06.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Real carotid arteries are elastic and perfused with a non-Newtonian fluid. The blood flow is pulsatile characterized by the reverse flow regions at the non-divider wall of internal carotid artery and external carotid artery. A coupling effect between fluid flow and elastic deformation is introduced. In addition we have calculated volumetric flow rate, pressure gradient and Impedance due to pulsatile flow in elastic carotid artery. We analyzed the flow at various locations in common carotid artery and internal carotid artery for different frequencies 60, 90, 120 pulse/min and Reynolds number 500 using a compliance mismatch model of carotid artery. Reverse flow of blood increases the impedance and should not be discarded. The problem has been analyzed mathematically and the agreement between present results and the available literature was found to be quite satisfactory. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1147 / 1156
页数:10
相关论文
共 50 条
  • [31] DECREASE IN PULSATILE FLOW IN THE INTERNAL CAROTID-ARTERY IN FETAL HYDROCEPHALUS
    DEGANI, S
    LEWINSKY, R
    SHAPIRO, I
    SHARF, M
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1988, 95 (02): : 138 - 141
  • [32] Characterizing pulsatile blood flow in a specific carotid bifurcation: insights into hemodynamics and rheology models
    Mouloud, Boukedjane
    Lakhdar, Bahi
    AIMS BIOPHYSICS, 2023, 10 (03): : 281 - 316
  • [33] Effects of waveform shape of pulsatile blood flow on hemodynamics in an artery bifurcation model
    Huang, Qiuxiang
    Sun, Jianhong
    Xu, Changyue
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2021, 235 (02) : 428 - 440
  • [34] Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model
    Prosi, M
    Perktold, K
    Ding, ZH
    Friedman, MH
    JOURNAL OF BIOMECHANICS, 2004, 37 (11) : 1767 - 1775
  • [35] Modeling the Effect of Red Blood Cells Deformability on Blood Flow Conditions in Human Carotid Artery Bifurcation
    Urevc, Janez
    Zun, Iztok
    Brumen, Milan
    Stok, Boris
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (01):
  • [36] Mathematical model of pulsatile blood flow in a distensible aortic bifurcation subject to body acceleration
    Chakravarty, S
    Mandal, PK
    Mandal, A
    INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2000, 38 (02) : 215 - 238
  • [37] Mathematical Modelling of Pulsatile Blood Flow in Straight Rigid Artery System
    Aniruddha Bhalchandra Pandit
    Sarvar Abbas
    Joydeb Mukherjee
    Transactions of the Indian National Academy of Engineering, 2022, 7 (3) : 1043 - 1057
  • [38] Pulsatile tinnitus and carotid artery dissection
    Shimizu, Yuya
    Yagi, Masato
    AURIS NASUS LARYNX, 2018, 45 (01) : 175 - 177
  • [39] Development of an in vitro setup for flow studies in a stented carotid artery bifurcation
    Hoving, Astrid M.
    Mikhal, Julia
    Kuipers, Henny
    de Borst, Gert J.
    Slump, Cornelis H.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (04) : 1165 - 1176
  • [40] Numerical analysis of flow through a severely stenotic carotid artery bifurcation
    Stroud, JS
    Berger, SA
    Saloner, D
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (01): : 9 - 20